HomeMy WebLinkAbout5.a. Request by Lennar Corporation for a Preliminary Plat and PUD for Prestwick Place 9thDIV(D"ISEMOUt EXECUTIVE SUMMARY
PLANNING COMMISSION
Planning Commission Meeting Date: June 25, 2013
Tentative City Council Meeting Date: July 16, 2013
AGENDA ITEM: Case 13 -25 -PP Request by Lennar
Corporation, Inc. for a Preliminary Plat &
Planned Unit Development (PUD) Final Site
AGENDA SECTION:
& Building Plan to Develop a 68 Lot
Public Hearing
Subdivision named Prestwick Place Stn
Addition
PREPARED BY: Clarissa Hadler,
AGENDA NO. 5.a.
Community Development Intern
ATTACHMENTS: Site Location Map; Comprehensive Plan;
Preliminary Plat; Preliminary Grading Plan;
APPROVED BY:
Preliminary Utility Plan; Preliminary Phasing
r
Plan; Preliminary Landscape Plan; City
l/
Council Resolution No. 2007 -92; Park
Dedication Ordinance 12 -3 -6 B.1.; Planned
Unit Development Ordinance 11 -10 -6 A. and
B.; City Engineer's Memorandum dated
June 18th, 2013; Park and Recreation
Director's Memorandum dated June 18tH
2013; Fire Marshall's Memorandum dated
June 10th, 2013
RECOMMENDED ACTION: Staff recommends the Planning Commission make the
following motion:
1. Motion to recommend the City Council approve the Preliminary Plat for Prestwick
Place 9th Addition, and final site and building PUD approval subject to conditions:
a. A deviation from City Code Section 11 -4 -5 F.1. to reduce the interior lot
minimum area of 10,000 to 8,300 square feet. Blocks 1 & 3 will retain the R1
standards of 10,000 square feet.
b. A deviation from City Code Section 11 -4 -5 F.2. to reduce the minimum lot
width to sixty -five (65) feet for interior lots and eighty (80) feet for corner lots
on Blocks 2 & 4. Per the conditions of City Council Resolution No. 2007.92
adopted October 2, 2007, Blocks 1 & 3 (formerly known as Blocks 1 & 2) will
retain standard 80 feet minimum lot width for interior lots, and 95 feet for
corner lots.
c. The home design front elevation shall include one of the following: a minimum
of three and a half (3.5) feet of brick or stone wainscoting, excluding doors,
windows or the wall behind the front porch; a front porch with railing that
extends at least 30% of the width of the front elevation, including the garage;
a side entry garage; or no more than 70% lap siding, excluding doors and
windows.
d. A deviation from City Code Section 11 -4 -5 F.4. to reduce the front yard
setback to twenty five (25) feet.
e. A deviation from City Code Section 11 -4 -5 F. 5. to reduce the side yard
setback to seven and one half (7.5) feet on Blocks 2 & 4. Blocks 1 & 3 will
retain the standard 10 feet side yard setback per the conditions of City
Council Resolution No. 2007.92 adopted October 2, 2007.
f. A deviation from City Code Section 11 -4 -5 F.9. to increase the maximum lot
coverage to thirty five percent (35 %) for lots in Blocks 2 & 4.
g. A sidewalk should be added along Alma Circle in front of Lots 28 — 31, Block
4.
h. One additional overstory tree should be added to Lot 6, Block 3 and Lot 5,
Block 4.
i. The proposed subdivision sign on Outlot B may not be placed on public
property.
j. Trees must be installed between home and adjacent right -of -way.
k. Trees installed on individual lots shall be planted in a location that does not
interfere with curb stops or individual sewer or water connections.
I. Drainage and utility easements with storm sewer infrastructure may contain
fences but shall be required to include gates to provide truck access; shall
prohibit sheds or other accessory structures; and shall prohibit landscaping
that would impede drainage.
m. Conformance with all requirements of the City Engineer as detailed in the
attached memorandum dated June 18th, 2013
n. Conformance with all requirements of the Parks and Recreation Director as
detailed in the attached memorandum dated June 18th, 2013.
o. Conformance with all requirements of the Fire Marshal as detailed in the
attached memorandum dated June 10th, 2013.
SUMMARY
Applicant: Lennar Corporation
Location: West of Akron Avenue about ' /z mile and bordered by County
Road 42 and Connemara Trail.
Gross Acres: 31 Acres
Met Council Net Acres: 22 Acres
Proposed Lots: 68 Lots
Gross Density: 2.19 Units /Acre
Net Density: 2.98 Units /Acre
Existing Comp Plan Designation: LDR — Low Density Residential
Existing Zoning: R1 PUD — Low Density Residential Planned Unit Development
The applicant, Lennar Corporation ( Lennar) requests approval of a Preliminary Plat and Planned Unit
Development (PUD) Final Site & Building Plan for the Prestwick Place 9`h Addition to allow 68 lots on
approximately 31 acres. The preliminary plat provides legal entitlement to a certain number of lots, but
actual developable lots would not be created until a final plat is approved. Lennar has stated that they plan
on submitting a final plat application this winter or next year. It is expected that Prestwick Place 9th will be
developed in two phases. Phase 1 will create 29 lots along the north side of development and six lots on the
2
south side adjacent to the existing Prestwick 7`h Addition for a total of 35 lots. Additionally the plat will
extend the park property along Connemara Trail by 3.63 acres and add 4.37 acres of ponding. Phase 2 will
create the remaining 33 lots in the central and western portion of the property.
BACKGROUND
Prestwick Place 9`h Addition is the seventh phase of single family developments within Prestwick Place, a
planned multi-use development. Prestwick Place will include commercial development at the corner of
Akron Avenue and County Road 42 with surrounding mix of high, medium and low density residential areas
and park. Prestwick Place Wh Addition completes development of Prestwick Place between the planned
commercial area to the east, existing Bloomfield to the west, Connemara Trail to the north, and County
Road 42 to the south.
General Subdivision Design
Prestwick 91h is approximately 31 acres between existing developments Falmoor Glen (also Lennar) and
Bloomfield, between Connemara Trail and County Road 42. There are 8 acres designated for parks and
ponding. Street systems include an extension of the existing street in Falmoor, one new street and one new
cul -de -sac, and a short extension of 142 "d Street. There is an exception property, Outlot A, at the southwest
corner to allow for drainage to a neighboring pond.
The Prestwick 9th property contains an existing 35 foot wide utility easement containing a Metropolitan
Council Sanitary Sewer that runs through the dedicated park and for the most part along the rear property
lines of lots on the north side of Block 4. The entire property is generally flat with approximately 25 feet of
elevation change throughout. Earlier studies had shown no evidence of wetlands. There is a stormwater
pond in the land adjacent to the development, southwest of the property that serves the Bloomfield
neighborhood. With the development of Prestwick Place, the City has installed a stormwater overflow pipe
to allow for drainage beyond the 100 year event.
Planned Unit Development Final Site & Plan
The subject property is currently zoned R1 PUD - Low Density Residential Planned Unit Development.
There are several deviations from the R -1 standards requested by Lennar, which is consistent with other
previously plated residential neighborhoods within Prestwick. The deviations requested include the following
for lots within Blocks 2 & 4: reduction in the minimum lot size from 10,000 square feet to 8,300 square feet;
reduction in the minimum lot width from 80 feet to 65 feet, reduction in the front yard setback from 30 feet
to 25 feet; reduction in the side yard setback from 10 feet to 7.5 feet; and the increase of the maximum lot
coverage from 30% to 35 %. The deviations from the R -1 standards for Blocks 1 & 3 are limited to just the
reduction in the front yard setback from 30 feet to 25 feet. The modified standards proposed by the
applicant are acceptable to staff.
Comparison of Lot
Requirements and Standards
Category
Current R -1
Standards
Prestwick Place
2nd and 3rd Standard
Proposed Prestwick Place
9t' Addition Standards
Blocks 1 & 3
Blocks 2 & 4
Min. Lot Area
10,000 s . ft.
8,500 s . ft.
10,000 s . ft.
8,300 s . ft.
Min. Lot Width
80 ft. (Interior)
95 s . ft. Corner
65 ft.
80 ft. (Interior)
95 s . ft. Corner
65 ft. (Interior)
80 ft. Corner
Min. Front Yard Setback
30 ft.
25 ft.
25 ft.
25 ft.
Min. Side Yard Setback
10 ft.
7.5 ft.
10 ft.
7.5 ft
Min. Rear Yard Setback
30 ft.
30 ft.
30 ft.
30 ft.
Max. Impervious Surface
30%
35%
30%
35%
3
Home Designs
Typical home designs will be two story facades and are located on the site to permit construction of a three
car garage. Lennar will be building homes with varying front facades that are consistent with homes in the
neighboring Falmoor Glen development.
Staff is proposing that all front elevation designs for the homes includes one of four design features:
• A minimum of three and a half (3.5) feet of brick or stone wainscoting, excluding doors, windows or
the wall behind the front porch;
• A front porch with railing that extends at least 30% of the width of the front elevation, including the
garage;
• A side entry garage;
• No more than 70% lap siding, excluding doors and windows.
Preliminary Plat.
The proposed preliminary plat would subdivide the 31 acre property into 68 single family lots. Eight (8) of
those 31 acres is set aside as Oudot B and consists 4.37 acres for ponding and 3.63 acres of parkland and is
adjacent to the existing parkland dedicated in the Prestwick 3rd Addition. Dedication of Outlot B will
complete City ownership of Prestwick Park.
Five streets are proposed to serve the development. Ailesbury Avenue will extend from the existing
Prestwick 3`d and connect to Connemara Trail. A short extension of 142nd Avenue will connect the
development to the Bloomfield neighborhood. Albany Avenue is an existing street, developed as part of
the Prestwick 7d' Addition. Aldbororough Avenue connects 142nd to Ailesbury and the exception property
on the south side, Outlot A. The stub at the south side of Aldborough Avenue allows for future
connection should the property to the south be developed in the future.
Alma Circle is a cul -de -sac off Albany Avenue and includes a landscaped island. City Code encourages
connections to the neighboring parcels and discourages cul -de -sacs. The City Code limits cul -de -sacs to
areas adjacent limited access roadways, as a result of topography, or adjacency to major utility corridors.
Staff is supportive of the cul -de -sac of Alma Circle because of the existing sanitary /sewer easement.
Additionally, making the road a "through" road would not provide any substantial improvements in
accessibility for residents.
Minimum lot widths for the majority of Prestwick Place will be 65 feet. However, City Council Resolution
No. 2007 -92 adopted October 2, 2007, requires 80 foot minimum lot standards be imposed on Blocks 1
& 3 along the west side where properties back up to the existing Bloomfield 6`h Addition, which also has
80 foot lots.
Lennar has proposed sidewalks on one side of all the streets except Alma Circle. Staff has prepared a
recommendation that sidewalks be installed adjacent to Block 4, Lots 28 — 31, on Alma Circle. Otherwise,
this sidewalk design provides for pedestrian and bicycle access to this subdivision and the neighboring
properties.
Landscape and Berming
The City Code requires a minimum number of overstory trees as one (1) tree per interior lot and two (2)
per corner lot. A minimum of 78 trees are required to meet this requirement. Lennar has proposed 79
trees, which includes the minimum of one tree per interior lot and two per corner lot. One additional
overstory tree should be added to the landscaping plan on Lot 6, Block 3 and Lot 5, Block 4. Also
proposed are 59 additional trees and shrubs along Connemara Trail, including surrounding the
development's monument sign at the corner of Ailesbury Avenue.
4
There is currently a neighborhood sign proposed on Oudot B, the land to be dedicated as City park and
ponding. Staff recommends the sign not be allowed on public property. To address this concern the
property lines should be modified, extending Lot 1, Block 2 to the south right -of -way line of Connemara
Trail.
Parks and Open Space
The Parks and Recreation Director has reviewed the Prestwick Place 9`'' Addition plans and is supportive
of the current plan for park space with the following two conditions; the sign should not be located on
City property and the deed for Outlot B (park parcel and ponding) be delivered to the City with the first
phase of the 9`i' Addition. Compliance with the Parks and Recreation Director's memorandum is included
as a condition of approval.
Per the Park Dedication Ordinance 12 -3 -6 B.1., the 68 proposed lots would require dedication of a
minimum of 2.72 acres of park land. The proposed park of 3.63 acres would leave a credit of .91 acres
from the Prestwick 9`' Addition. Lennar currently has a credit of .4 acres of park land from Prestwick 7`''
Addition. This would leave a Lennar with a total of 1.31 acres of park credit. Staff will work with Lennar
to determine where that credit will be applied within the entire Prestwick Place neighborhood.
Engineering Comments
The Assistant City Engineer has reviewed the Prestwick Place 9`" plans and has some minor concerns
regarding the proposed subdivision. The developer will be responsible for costs associated with adjacent
roadways; including past improvements to Connemara Trail and Akron Avenue, and future extension of
Ailesbury Avenue. Trees located on individual properties shall not be planted near the sanitary sewer and
water service lines and should not be located over storm sewer pipes or within emergency overflow routes
or overland flow routes. Compliance with the City Engineer's memorandum is included as a condition of
approval.
Legal Authority
As discussed during legal training, a preliminary plat and rezoning request is a quasi - judicial decision for the
Planning Commission meaning that the Planning Commission is acting as a judge to determine if the
regulations within the Comprehensive Plan, Zoning Ordinance and Subdivision Ordinance are being
followed or if the Code deviations requested within the Planned Unit Development is appropriate. The
Comprehensive Plan states that R1 is the proper zoning district for the property. The lot dimension
deviations requested represent less than a 10% reduction from the City Code requirements and the setback
deviations are less than 20% reduction from the standard. These modifications are consistent with other
neighborhoods within the Prestwick project. Additionally, the lots immediately adjacent to Bloomfield are
consistent in dimensions and setbacks from the previously developed Bloomfield neighborhood.
A Planned Unit Development (PUD) is allowed for in Ordinance 11 -10 -6 A.5. in order to more efficiently
and effectively "use land, open space and public facilities through mixing of land uses and assembly and
development of land into larger parcels" and in Ordinance 11 -10 -6 A.7. for the "sensitive development in
transitional areas located between different land uses and along significant transportation or scenic corridors
within the city ". Considering that the entire Prestwick Place development is a 295 acre mixed use
development, the use of a PUD is appropriate given the position of Prestwick Place 9`'' Addition between
the planned commercial development at Akron and County Road 42 and the existing R1 single - family
Bloomfield development. The Prestwick Place 9`h Addition is part of the earlier Master Development /
PUD for Prestwick Place, which allows for mixed land uses, according to Ordinance 11 -10 -6 B.Lb.
61
CONCLUSION & RECOMMENDATION
Staff recommends approval of a Preliminary Plat and Planned Unit Development (PUD) Final Site &
Building Plan with the conditions listed.
t�
Prestwick Place 9th
I'
ry
�w
.I _ . I III NOW&AAA16M
Disclaimer: Map and parcel data are believed to be accurate, but accuracy is not guaranteed. This is not a Map Scale
legal document and should not be substituted for a title search, appraisal, survey, or for zoning 1 inch = 800 feet
verification. Dakota County assumes no legal responsibility for the information contained in this data. 6/18/2013
P
am
�a
� � E
_t a
Kh� Y
s
\ dA
�\ C
`i
II�
I \
\
\
\ \�, —� \� <, \,Y / � \ � k -7
0
to,
FI Y
Oil
1
li
u) 3
Ijl
gill
1
ow-, I
a
a
L
u
a �
z
O
F
°z
a
�
�
g
�S�1vaQ
� �YSb��
i'�Rq
o4
s
\ dA
�\ C
`i
II�
I \
\
\
\ \�, —� \� <, \,Y / � \ � k -7
0
to,
FI Y
Oil
1
li
u) 3
Ijl
gill
1
ow-, I
a
a
u
a �
z
O
F
°z
a
\ dA
�\ C
`i
II�
I \
\
\
\ \�, —� \� <, \,Y / � \ � k -7
0
to,
FI Y
Oil
1
li
u) 3
Ijl
gill
1
ow-, I
Sage
=OU�
i � E
/ I
\ / i
\ �r
/
J
ninlll�/7i� LJin -7-7
I.Lwvv\ y v _
I<< \ \ yZj - -I --
W x
s °a iF s
� 4
q '
�a
Fa
8
° � a
V
� a
Z - .d
O
ii
zz P,
0
VI
RN
o
V�
1;11
Hi a
--- I- -L -L�\ / 4i
3
_ - -�
igEaa
°a
/ I
\ / i
\ �r
/
J
ninlll�/7i� LJin -7-7
I.Lwvv\ y v _
I<< \ \ yZj - -I --
W x
s °a iF s
� 4
q '
�a
Fa
8
° � a
V
� a
Z - .d
O
ii
zz P,
0
VI
RN
o
V�
1;11
Hi a
--- I- -L -L�\ / 4i
`3S`g
ea�
a0S
F
cq
/
^b
b
�a
xa
s g�
$ M
g
o
z
O 47
o ti�
o p,
z
1 1 b
I � N
cz
I �
r7
b 0 N
^^ C�
I F-1 91 F�
It 1 I (n C1 S P_
I
N
l
, r
I
:IFq O1 aaG
l /
I` ninivinn� LJIn In'i -11 --
i
J l, J Iy —Iv - -L- -L�
NZ
I \ ,
fi
gk
E
A
s,
dig
s
1
.111
1�Nj�1 1
i� :P;
i I
a� aff� sa��� o$ yyF €g a gogooa000 °
him m,
o
05!g x
6� MAX Z8
@23
a� ea=�<
. . . .. .. . .. . . . .
Or
LLJ
r
\� y
I
"
,I
I
I '
I ,
I I
I
i
i
�c7C ,x\�✓i�nly LJ y .. i� i_ �rrvvvl i�� l I /
1 �_ — "1 -- -- 1-- L - -L, —r
". �../ L - - - - -- J k - - - - -�
1
•
•
•
•
s
•
f, y
�Y
�• iF7a iF I t ' /
*ter —.. ,ra ••cw�.c��.cf -� �i ,
�1 +�'�t,. � i � •:ca \ iii
ih • -1 i, ii, '
i�?�I*.:i�� IN�t,.. L ■lttydl _� 1 IIL4'Jl� N
1791 �•
r #• h,F #r�:ta�sca�.cs�r_s�•cf�.. /,
Rra
w
L J
e�
3
aDS
Z
9
H
O
m
F
� 111I
�u
t�
!i! a
1
R
a ROD
Wq'.— 1
a A a yoy
w .1
Pang
Si HE, H
oo
rA
z
9
H
O
m
F
� 111I
�u
t�
!i! a
1
R
i
�e
t
� n9►
r r
y\ r
r r
i
r
r \
� r r
v r
r
r
r 1 �
1 r -
r �
I I � r ! j N °� ♦ b
I
1 I.
I
I
1
tt 11 II II li '
, 4t _
1 �
r r �-ti1
J :_. , -- � �x a i I it � � � �" � � � R r• a'�
l
r- -
i\vv v LJ �n : IIn i i/^I /ni11 � 7
y L I_J` JY1Y l.f VI,I C I. );ice.
J
s
z
�I
I
effi
Ot
$` 9 < 7n a m 4 I
Oxamgyp
9 �85a =g.
N °
4 w pax gw �xp § ova x aa �g
W a € s <m a
3i r mo a€ 3; €N a g�a ._ N E` ea�s 9 -8
< ga fie€ wli— Til ggN _" ; a' 2
€ x,81 g RF my a�� e, m g oaj
F'° a� g= €g 3Wa ohs R
� a�aw R aaaa�e �, � € ap ��
€ g
Vigo
R < =E <a €Rg .a���� @ � m g = g "e
u
U
I J
V
I I'
I I�
i
L._.—.—.—.—.—.—.—.—
.___________________________J
r-
0
I L
0
I V I
3
B
a
i
S
�a
�a
s fA
u
$ u
E ° W
8ao� z
yyip pp;;
}s}R
yyAe
JAI 419,11 IV 11
08
g�{_gEs $Ry
>� Px
e< a
$€
i
a 4
y d g a6y!xj
m; m
S�
yypz
Y ?N
-z u
-z
k'
�a
�a
s fA
u
$ u
E ° W
8ao� z
yyip pp;;
}s}R
yyAe
JAI 419,11 IV 11
g�{_gEs $Ry
>� Px
i
a 4
y d g a6y!xj
S�
oil
V
1�
11�
1
�a
''1 g
Mill
If I
tD
6f17/13
Sterling CoMers, Inc.
H Y '09? -A" ODE ONIANE -SAJVPEJ6-1'- "
Toe Results Ada Search
C C3 C3 Text Q C3 Fvi. Another Tiviines Search Minnesota Codes park de
0 Rosemount, Minnesota: City Code
1o' ORDINANCES PENDING CODIF"
Please contactthe municipality for questions regarding regulations.
Q PREFACE
Rosemount MN webl2aw / (651) 423-4411
tj' Title I -ADMINISTRATION
123$: PARK DEDICATION: it
tj Title 2 - BOARDS AND COMMISSIC
*-iw Tide 3 - BUSINESS REGULATIONS
n Ttle 4 - STREETS AND PUBLIC PR
Title 6- HEALTH AND SANITATION
A. Comprehensive Plans: Where a proposed park, trailway, ponding, or open space area, shown on the city's comprehensive guide
Title 6 - FIRE PREVENTION AND PI
guide, comprehensive storm sewer plan or official map, is located in the whole or in part in a subdivision, such area or areas shi
Ttle 7 - POLICE REGULATIONS
preliminary plat. Such area or areas shall also be dedicated to the city by the subdivider if the council requests such dedication
Mile 8 - TRAFFIC AND MOTOR V&
subsections below.
*--4 Title 9 - BUILDING REGULATIONS
Title 10 - WATER RESOURCES MA
rt Title 11 - ZONING REGULATIONS
B. Dedication: In all subdivisions, the city shall require that a reasonable portion of such land be set aside and dedicated to the pub
Title 12 - SUBDIVISION REGULATK
other public use exclusive of property dedicated for streets and other public ways.
Chapter 11i GENERAL REQUIREA
Chapter 2: PLAT PROCEDURES
1. In all residential subdivisions it shall be presumed that a reasonable amount of land has been dedicated for parks and playgn
Chapter 3: SUBDP41SION DESIGI
dedicates at least one twenty-fifth (1/25) of an acre for each dwelling unit of the proposed subdivision (acres to be dedicated
12-3-1: STREET DESIGN STAI
units). The city shall determine whether a cash payment in lieu of land dedication is appropriate. The amount of cash dedicati,
12-3-27. STREET SECTIONS:
multiplying the number of dwelling units of the proposed subdivision times the designed fee per dwelling which may be set fror
123-3: SIDEWALKS, TRAILS,
of the council. (Ord. B-91, 8-5-1997, eff. 8-11-1997)
12-34: EASEMENT DETAILS:
2. In all commercial, industrial and other subdivisions, it shall be presumed that a reasonable amount of land has been dedicate,
E) 12,3-5: LANDLOCKED PAR CE
resident and working population for parks and playgrounds if the subdivider dedicates at least ten percent (10%) of the land 1i
123-6. PARK DEDICATON:
recreation and usable open space. The city shall determine whether a cash payment in lieu of land dedication is appropriate.
12-3-7: REQUIRED IMPROVE f
dedication shall be determined by multiplying the number of acres (determined by application of the formula stated above) tim
12-3-8-, GRADING OF SITE PR
acre which may be set from time to time by resolution of the council.
Chapter 4: VARIANCES, EXCEP'
Chapter 5: ADMINISTRATION AN
3 The dedication of a portion of land for parks or playgrounds, or the payment of cash in lieu thereof, provided for above shall I
reasonable. However, upon the request of the applicant, the recommendation of the park and recreation commission, or at tht
the city may either increase or decrease such dedication or payment upon a determination by the council that such dedicatior
unreasonable or insufficient given the specific characteristics of the proposed subdivision and its intended use. (Ord. XVII.107
4. Ponding areas, needed as part of the overall city storm drainage plan, shall be dedicated as land or easement at the option c
by the city. However, no credit shall be given for park dedication unless said area meets the criteria for public parks as stated
resolution and is approved by the council. Said dedication of land or easement shall be in a form approved by the council.
5. In the case of subdivisions of land Mich have previously been subdivided and for which land has been dedicated for parks of
payments in lieu of such dedication have been made, the council shall make reasonable adjustments to recognize such previc
C. Timing Of Park Dedication: R a new subdivision is designed to be platted into more than one addition, all park and other public u:
under this section in the total subdivision area, shall be dedicated with the final plat of the first phase or addition of the subdivisi,
approved by the council.
w.vw.sterlingcochfiers.corrYcodebooMndexphp?booli id=452
11-Ti F-M 191
Sterling Codifiers, Inc.
11 -10 -6: PLANNED UNIT DEVELOPMENTS (PUD):
A. Purpose: The purpose of the planned unit development (PUD) district is to provide a district
that will encourage the following:
1. Flexibility in land development and redevelopment in order to utilize new techniques of
building design, construction and land development.
2. Provision of life cycle housing to all income and age groups.
3. Energy conservation through the use of more efficient building designs and sitings and
the clustering of buildings and land uses.
4. Preservation of desirable site characteristics and open space and protection of sensitive
environmental features, including, but not limited to, steep slopes, trees and poor soils.
5. More efficient and effective use of land, open space and public facilities through mixing of
land uses and assembly and development of land into larger parcels.
6. High quality of design and design compatible with surrounding land uses, including both
existing and planned.
7. Sensitive development in transitional areas located between different land uses and
along significant transportation or scenic corridors within the city.
8. Development that is consistent with the comprehensive plan.
B. Development Standards: Within the PUD district, all development shall be in compliance with
the following:
1. Uses: For a given PUD, all uses shall be consistent with the comprehensive plan and the
master development plan as approved.
a. Area Used For Land Uses: The city may permit up to ten percent (10 %) of the gross
floor area of all buildings in a PUD to be used for land uses for which the site is not
designated in the comprehensive plan if the city council finds that such use is in the best
interests of the city and is consistent with the requirements of this chapter. If
nondesignated uses are to be incorporated into a PUD, the city may forward a copy of
the request to the metropolitan council for review.
b. Designated For More Than One Use: Where the site of a proposed PUD is designated
for more than one land use in the comprehensive plan, the city may require that the
PUD include all the proposed land uses.
c. Single Land Use Or Housing Type: Any PUD which involves a single land use type or
housing type may be permitted; provided, that it is otherwise consistent with the
objectives of this title and the comprehensive plan.
2. Area: Each PUD shall have a minimum area of ten (10) acres, excluding areas within a
www. sterlingcodifiers .con✓codebookindexphp ?book id =452 117
4ROSEMOUNT
PARKS AND RECREATION
M E M O R A N D U M
To: Kim Lindquist, Community Development Director
Eric Zweber, Senior Planner
Jason Lindahl, Planner
Andy Brotzler, Public Works Director /City Engineer
Phil Olson, Assistant City Engineer
From: Dan Schultz, Parks and Recreation Director
Date: June 18, 2013
Subject: Prestwick Place — 9th Addition Preliminary Plat
The Parks and Recreation Department recently received the plat for the Prestwick Place 9th
Addition. After reviewing the plans, the Parks and Recreation Department staff has the following
comments:
PARKS DEDICATION
The parks dedication requirement for the 68 units in the 9th addition is either 2.72 acres of land or
cash in lieu of land. Staff is recommending that the developer dedicate land to satisfy the parks
dedication for the 9th addition. There are 3.63 acres of park land identified within Oudot B of the 9th
addition plat. Because the developer is proposing to dedicate more land than is required, the
developer will have a parks dedication credit of .91 acres of land for the 9t' addition. This credit will
be combined with a credit that the developer had from the 3`d and 7th additions of .40 acres. Staff is
recommending that Lennar use the 1.31 acres of parks dedication credit within the Prestwick Place
development.
Staff is recommending that the deed for Oudot B (park parcel and ponding) be delivered to the City
with the first phase of the 9d' addition.
The plans for the 9th addition identify a private monument sign located at the corner of Ailesbury
Avenue and Connemara Trail. Staff is recommending that the monument sign be located on private
property.
Please let me know if you have any questions about this memo.
4ROSEMOUNT
FIRE DEPARTMENT
M E M O R A N D U M
To: Eric Zweber, Planner
From: Dale Chard, Fire Marshal
Date: June 10th, 2013
Subject: Prestwick Place 9t" Addition
Upon review of the Prestwick Place 9th Addition Preliminary PUD Submittal dated
5/23/13 provided for review by Westwood Professional Services Inc. on behalf of
Lennar Corporation the Fire Marshal offers the following comment:
• No comments are noted.
Thank you,
Dale Chard
City of Rosemount Fire Marshal
651 - 322 -2027
A46murf--RL4r
CITY OF ROSEMOUNT
DAKOTA COUNTY, MINNESOTA
RESOLUTION NO. 2007„ 92
A RESOLUTION APPROVING THE PLANNED UNIT DEVELOPMENT (PUD) MASTER
DEVELOPMENT PLAN WITH REZONING FOR PRESTWICK PLACE
WHEREAS, the Community Development Department of the City of Rosemount received
an application from Arcon Development requesting a planned unit development (PUD)
master development plan with rezoning concerning property legally described as:
The South Half of the Northwest Quarter except the West 600 feet of the South 400
feet thereof, and the West Half of the Northeast Quarter of Section 27, Township 115
North, Range 19 West, Dakota County, Minnesota.
i .`l
That part of the East Half of the Southwest Quarter of Section 22, Township 115
North, Range 19 West, lying southerly of the southerly right of way line of the
Chicago, Rock Island and Pacific Railroad, Dakota County, Minnesota. Torrens
Property Cert #135831.
The North Half of the Northwest Quarter of Section 27, Township 115 North, Range
19 West, excepting therefrom the following: Commencing at the northeast corner of
said Nord-. Half of the Northwest Quarter; thence South along the quarter section line,
a distance of 627.87 feet to the actual point of beginning of the property to be
described; thence West 208.71 feet; thence South 417.42 feet; thence East 208.71 feet
to the said quarter section lime; thence North, along the quarter section line, a distance
of 417.42 feet to the point of beginning and except the South 208.71 feet of the East
417.42 feet thereof. Tottens Property Cert #135831.
That part of the West Half of the Southwest Quarter of Section 22, Township 115
North, Range 19 West, lying southerly of the southerly right of way line of the
Chicago, Rock Island and Pacific Railroad, Dakota County, Minnesota. Abstract
Property.
WHEREAS, on July 24, 2007, August 28, 2007, and September 11; 2007, the Planning
Commission of the City of Rosemount held a public hearing and reviewed the requested
application; and
WHEREAS, on September 11, 2007, the Planning Commission recommended approval of
the requested applications, subject to conditions; and
WHEREAS, on October 2, 2007, the City Council of the City of Rosemount reviewed the
Planning Commission's recommendations.
RESOLUTION 2007 - 9 2
NOW, THEREFORE, BE IT RESOLVED, the Council of the City of Rosemount hereby
approves the planned unit development (PUD) master development plan of Prestwick Place
and the Rezoning of the Arcon single family residential from AG — Agricultural to R1 PUD --
Low Density Residential Planned Unit Development; the Lennar and Dakota County
Community Development Agency townhouses from AG — Agricultural to R3 PUD — Medium
Density Residential Planned Unit Development; the Dakota County Community
Development Agency apartments from AG — Agricultural to R4 PUD — High Density
Residential Planned Unit Development; and the Arcon commercial area from AG —
Agricultural to C4 PUD — General Commercial Planned Unit Development, subject to:
1. R1 PUD lots have a minimum lot width of 72 feet, a front yard setback of 25 feet, a 5
foot garage side yard setback, a house side yard setback of 10 feet, a rent yard setback
of 30 feet, and minimum lot size of 9,500 square feet, except that the lots of Block 1
and 2 are required to have a minimum lot width of 80 feet and both side yard setbacks
are 10 feet.
2. R3 PUD neighborhoods have a setback from the public street of 25 feet, a setback
from property lines of 30 feet, a minimum building separation of 20 feet, and a
minimum parking setback of 20 feet.
3. The Dakota County Community Development Agency townhomes are permitted to
have a single car garage.
4. R3 PUD buildings have a maximum of 12 units per building.
5. Garages on single fairly houses on corner lots shall be located on the opposite side of
the house from the public street.
6. Setbacks from the Connemara Trail section that has only 85 feet of right -of -way will
be measured as if the right-of-way is 100 feet wide. Fences or other residential
accessory structures will not be allowed in this setback area.
7. Final landscape plans will need to be submitted with the final plat and construction
plans. Modifications to the final landscaping plans may be required by the City
Planner or City Engineer if any landscaping would interfere with street signage,
infrastructure or other design issues.
8. The applicant shall apply for and receive final site plan and final development plan
approval for the Dakota County Community Development Agency portion of the plat.
Additional information regarding landscaping, stormwater management; pedestrian
access and architecture and other ordinance requirements must be submitted for City
review and approvaL The unit counts for the proposed Dakota County CDA
development assumes that there is sufficient space to install the needed infrastructure
while meeting all ordinance requirement not expressly waived within this approval.
Failure to meet ordinance requirements may result in a reduction in the total number
of units permitted to be constructed.
9. The applicant shall apply for and receive final site plan and final development plan
approval for the Arcon commercial area (oudots G and J). Additional information
regarding landscaping, stormwater management, pedestrian access and architecture and
other ordinance requirements must be submitted for City review and approval. The
development of the commercial areas is subject to conditions stated within Prestwick
Place Commercial Area Guidelines dated September 7, 2007.
RESOLUTION 2007 - 9 2 .
10. The final construction plans for the Lennar townhouse playgrounds and picnic areas
need to be reviewed and approved by City staff to ensure that the structures and
equipment installed meet industry standards and is adequately sized for the amount of
residents in the neighborhood.
ADOPTED d-i s 2nd day of October, 2007 by the City Council of the City of Rosemount.
William H. Droste, Mayor
ATTEST:
Amy Domeier, City Clerk
Motion bT Shoe-Corrigan _ , Secondby: Sterner,
Voted in favor: Shoe-Corrigan, Droste, Sterner, Baxter, DeBettignies
Voted against:
Member absent:
None
4ROSEMOUNT
PUBLIC WORKS
MEMORANDUM
DATE: June 18, 2013
TO: Clarissa Hadler, Community Development Intern
CC: Kim Lindquist, Community Development Director
Andrew Brotzler, Director of Public Works /City Engineer
Dan Schultz, Parks and Recreation Director
Eric Zweber, Senior Planner
Christine Watson, Public Works Coordinator
Kathie Hanson, Planning Department Secretary
FROM: Phil Olson, Assistant City Engineer
RE: Prestwick Place 9t" Addition Engineering Review
SUBMITTAL:
Prepared by Westwood Engineering, the Prestwick Place 9th Addition Plans for Preliminary Plat are
dated May 21, 2013. Engineering review comments were generated from the following documents
included in the submittal:
Prestwick Place 9t' Addition Preliminary Plans for Preliminary Plat Submittal (13 pages)
including:
• Existing Conditions & Survey
• Preliminary Plat
• Preliminary Grading, Drainage & Erosion Control Plan
• Preliminary Utility Plan
• Preliminary Landscape Plan
• Preliminary Centerline Profiles and Details
• Stormwater Runoff Calculations, dated May 21, 2013
DEVELOPMENT FEES:
1. Development fees will be based on the city's current fee resolution at the time of the final
plat. Development fees are due with the final plat and subdivision agreement.
2. Per the existing Joint Development and Cost Sharing Agreement, the developer is
responsible for the costs of adjacent roadways. These costs are as follows:
• The developer is responsible for costs associated with upgrading Akron Avenue. This
cost is $270.28 /acre or $8,368 for all phases of this development.
The developer is responsible for costs associated with the recent extension of
Connemara Trail between Bloomfield and Akron Avenue. This cost is estimated at
$7,771.41 /acre or $240,603.
• The developer is responsible for the future development of Connemara Trail east of
Akron Avenue. This cost is $3457.20/acre or $107,035.
The developer is responsible for the remaining cost of Ailesbury Avenue with Phase 1.
This cost is estimated at $7,731 /acre or $113,953. The Prestwick Place 3`d Addition and
Prestwick Place 7d' Addition have already contributed to a portion of this roadway.
SITE PLAN COMMENTS:
3. Trees located on individual properties shall not be planted near the sanitary sewer and water
service lines. These trees shall be positioned near the property lines.
4. Streetlights should be shown on the grading plan.
5. A permit will be required for all improvements within the MCES easement.
6. Roadway and utility improvements for Lot 9 and Lot 10, Block 3 will be completed with
Prestwick Place 7d' Addition. These lots could be added to Phase 1 without any additional
improvements.
EASEMENT COMMENTS:
7. Conservation easements are required over all stormwater ponds, infiltration basins, wetlands,
and buffers. Signage for conservation easements shall be provided by the developer and an
extended 5 year maintenance warranty shall be required to ensure establishment of the
naturally vegetated areas. Costs associated with the establishment of the naturally vegetated
areas and the 5 year maintenance period shall be a cost of the development.
8. Storm sewer is proposed along the side and back lot lines of certain properties to convey
rear yard drainage. Drainage and utility easements along these lines shall prohibit the
installation of sheds to ensure that access can be provided for storm sewer maintenance.
Fences are allowed but shall not restrict drainage and are required to include gates for truck
access over the drainage and utility easement. Also, landscaping that will block access should
be prohibited. These restrictions should be added as a restriction on the property deed.
This will impact the following properties:
• Block 1: Lot 1 through Lot 5
• Block 2: Lot 4 and Lot 5
• Block 3: Lot 1 through Lot 6
• Block 4: Lot 1 through Lot 4, Lot 13 through Lot 19, Lot 23, Lot 26 and Lot 27, Lot 29
through Lot 34, Lot 37 through Lot 41
9. Trees should not be located over storm sewer pipes or within emergency overflow routes or
overland flow routes. Additionally, trees located on individual properties should not be
planted near the sanitary sewer and water service lines. These trees should be positioned a
minimum of 15 feet from the service lines.
10. The width of drainage and utility easements over all public utilities shall be verified during
final design.
11. Drainage and utility easements in the rear yards of many lots are required to be extended
based on the proposed emergency overflow elevation. Below is a listing of lots where the
drainage and utility easements require revisions.
• Lot 4 through Lot 6, Block 1 should be increased to encompass the drainage to 939.10.
• Lot 4 through Lot 6, Block 3 should be increased to encompass the drainage to 937.40.
• Lot 19, Lot 20, Lot 23 through Lot 25, Lot 30, and Lot 3, Block 4 should be increased
to encompass the drainage to 934.70.
• Lot 25 through Lot 29, Block 4 should be increased to encompass the drainage to
934.00.
• Lot 1, Lot 2, Lot 40, and Lot 41, Block 4 should be increased to encompass the
drainage to 931.50.
• Lot 13 through Lot 18 and Lot 32 through Lot 35, Block 4 should be increased to
encompass the drainage to 936.30.
• Lot 3 and Lot 4 and Lot 36 through Lot 39, Block 4 should be increased to encompass
the drainage to 932.70.
STORMWATER MANAGEMENT:
12. The stormwater management plan should be updated to reflect the modifications made to
the Prestwick 4th Addition drainage plans. This modification should be reflected in the
stormwater storage calculations, high water level, and infiltration system analysis. The
additional drainage area is not anticipated to change the site design for this development.
13. The storm sewer drainage area map and storm sewer design calculations should be provided.
The preliminary design is used to verify the adequacy of the easements being provided over
rear yard storm sewer.
14. Additional infiltration testing data is required to verify that the rate control design is in
conformance with City requirements. The infiltration testing should be completed during
site grading and at the proposed grading plan elevations.
Should you have any questions or comments regarding the items listed above, please contact me at