HomeMy WebLinkAbout6.j Receive Specifications/Authorize Ad Bid for Fire Tanker Vehicle for Fire DepartmentAGENDA ITEM: Receive Specifications/ Authorize Ad for
Bid for Fire Tanker Vehicle for Fire Dept.
AGENDA SECTION:
CONSENT
PREPARED BY: Linda Jentink, City Clerk
AGENDA #6
ATTACHMENTS: Specifications, Public Notice
APPROVED BY:
RECOMMENDED ACTION: MOTION to receive the specifications and author the ad for
bid for a fire tanker vehicle for the Rosemount Fire Department with the bid opening on
October 11, 5:00 p m.
4 ROSEMOUN 1'
CITY COUNCIL
City Council Regular Meeting: September 6, 2005
EXECUTIVE SUMMARY
ISSUE
City Council's consideration is requested to accept the bid specifications for a fire tanker vehicle for the
Fire Department and authorize pubhshuig the ad for bid.
BACKGROUND
The Fire Department has requested the purchase of a fire tanker vehicle. Fire Department Captain Mike
Reis headed a Fire Dept committee to review the options in the specifications that would best suit the
City of Rosemount. This vehicle is in the Capital Improvement Program for 2005 in the amount of
$190,000.
The bids will be received for thirty days following publication with the formal bid opening on October 11,
2005 at 5.00 p.m. The City Council may consider the bid results at the October 18 regular meeting
pending review of the bid tabulations.
SUMMARY
Staff recommends a motion to receive the specifications and authorize the ad for bid for a fire tanker
vehicle for the Rosemount Fire Department with the bid opening to be held on Tuesday, October 18,
2005 at 5:00 p.m.
4 ROSEMOUNT
Contact: Linda Jentink, City Clerk
Rosemount City Hall
2875 145 ST W
Rosemount, MN 55068
651- 322 -2003
MINNESOTA
General Instructions, Requirements, and
Specifications for
ONE (1) FIRE TANKER VEHICLE
September 6, 2005
S P E C I F I C A T I O N P R O P O S A L
Vehicle Configuration,°
FREIGHTLINER M2 106 CONVENTIONAL CHASSIS
SET BACK AXLE -TRUCK
STRAIGHT TRUCK PROVISION
LH PRIMARY STEERING LOCATION
General Service c
TRUCK CONFIGURATION
DOMICILED ROSEMOUNT MN
FIRE SERVICE
EMERGENCY VEHICLES BUSINESS SEGMENT
FIXED LOAD COMMODITY
TERRAIN /DUTY 10% (SOME) OF THE TIME, IN
TRANSIT, IS SPENT ON NON -PAVED ROADS
MAXIMUM 8% EXPECTED GRADE
MAINTAINED GRAVEL OR CRUSHED ROCK MOST
SEVERE IN- TRANSIT (BETWEEN SITES) ROAD
SURFACE
MEDIUM TRUCK WARRANTY
EXPECTED FRONT AXLE(S) LOAD 14000 0 Ibs
EXPECTED REAR DRIVE AXLE(S) LOAD 30000.0
Ibs
EXPECTED GROSS VEHICLE WGT CAPACITY'
44000 0 Ibs
�`Ttuck;Seniice'.
Engine
Rosemount MN MWF
FIRE TANK 1 PUMPER
CAT C7 330 HP 2400 RPM 860 LB /FT 1440 RPM
R/F/E
'L--Engine-Equipment.
2004 EPA/CARB EMISSION CERTIFICATION
ENGINE MOUNTED OIL CHECK AND FILL
ONE PIECE VALVE COVER
NFPA COMPLIANT EMBER SCREEN AND FIRE
RETARDANT DONALDSON AIR CLEANER
07/26/2005 9 55 AM
Page 1 of 8
ransmission
ALLISON 3000 EVS AUTOMATIC TRANSMISSION
WITH PTO PROVISION
ransrnission Equipment
5 SPEED EVS (PACKAGE 120)
VEHICLE INTERFACE WIRING AND PDM WITH BODY
BUILDER CONNECTOR AT END OF FRAME
ELECTRONIC TRANSMISSION CUSTOMER ACCESS
CONNECTOR MOUNTED BACK OF CAB
MAGNETIC PLUGS, ENGINE DRAIN, TRANSMISSION
DRAIN, AXLE(S) FILL AND DRAIN
PUSH BUTTON, ELECTRONIC SHIFT CONTROL,
DASH MOUNTED
TRANSMISSION OIL CHECK AND FILL WITH
ELECTRONIC OIL LEVEL CHECK
Rosemount MN MWF
LN 12V 270 AMP 4949PA PAD MOUNT ALTERNATOR
WITH AC TAPS
(3) ALLIANCE 1031 GRP31 12V MF 2280 CCA
THREADED STUD BATTERIES
SINGLE BATTERY BOX FRAME MOUNTED LH
SIDEUNDER CAB
FRAME GROUND RETURN FOR BATTERY CABLES
NON POLISHED BATTERY BOX COVER
POSITIVE POST FOR JUMP START
BW 13 2 CFM COMPRESSOR (SERIES 550)
TEFLON COMPRESSOR DISCHARGE LINE
GVG, FIRE AND EMERGENCY SERVICE VEHICLES
ENGINE WARNING
PAC -BRAKE EXHAUST BRAKE
SINGLE HORIZONTAL MUFFLER WITH HORIZONTAL
TAIL PIPE EXHAUST, RIGHT -HAND MOUNTED
HORTON DRIVEMASTER ON /OFF FAN DRIVE
AUTOMATIC CONTROL WITHOUT DASH SWITCH
CAT SPIN ON FUEL ALTER
FULL FLOW OIL FILTER
1000 SQ -IN ALUMINUM RADIATOR
ANTIFREEZE TO -34F, ETHYLENE GLYCOL PRE
CHARGED SCA HEAVY DUTY COOLANT
RUBBER COOLANT HOSES
CONSTANT TENSION HOSE CLAMPS FOR
COOLANT HOSES
IRON FLYWHEEL HOUSING
AIR INTAKE WARMER
DELCO 12V 38MT HD STARTER
07/26/2005 9:55 AM
Page 2 of 8
Front Axle and Equipment`
MFS-14-143A 14,700# FF1 SINGLE FRONT AXLE
MERITOR 16 5X5 0+ CAST SPIDER CAM FRONT
BRAKES, DOUBLE ANCHOR, FABRICATED SHOES
FIRE AND EMERGENCY SEVERE SERVICE, NON
ASBESTOS FRONT LINING
CONMET CAST IRON FRONT BRAKE DRUMS
CHICAGO RAWHIDE SCOTSEAL FRONT OIL SEALS
VENTED FRONT HUB CAPS OIL
STANDARD SPINDLE NUTS FOR ALL AXLES
MERITOR AUTOMATIC FRONT SLACK ADJUSTERS
TRW TAS -85 POWER STEERING
POWER STEERING PUMP
2 QUART SEE THROUGH POWER STEERING
RESERVOIR
F ront Suspen §_ion
14,600# TAPERLEAF FRONT SUSPENSION
MAINTENANCE FREE RUBBER BUSHINGS FRONT
SUSPENSION
FRONT SHOCK ABSORBERS
Rear Axle and Eq pme%tt
RS -30 -185 U- SERIES REAR AXLE 30,0004f
5 38 AXLE RATIO
IRON REAR AXLE CARRIER HOUSING
17T MERITOR MAIN DRIVELINE W /HALF ROUND
YOKES
MERITOR 16 5X7 "P" CAM REAR BRAKES, DOUBLE
ANCHOR, CAST SHOES
FIRE AND EMERGENCY SEVERE SERVICE, NON
ASBESTOS REAR LINING
CONMET CAST IRON REAR BRAKE DRUMS
CHICAGO RAWHIDE SCOTSEAL REAR OIL SEALS
HALDEX LONG STROKE 1 -DRIVE AXLE PARKING
CHAMBERS
MERITOR AUTOMATIC REAR SLACK ADJUSTERS
Rear Suspension,,
Brake System„"
AIR BRAKE PACKAGE
31,000 LB FLAT LEAF SPRING REAR SUSPENSION
W/ RADIUS ROD FOR FIRE EMERGENCY SERVICE
SPRING SUSPENSION t50" AXLE SPACER
CUSTOM AXLE CLAMP GROUP
Rosemount MN MWF 07/26/2005 9 55 AM
Page 3 of 8
,Trailer Connections
UPGRADED CHASSIS MULTIPLEXING UNIT
UPGRADED BULKHEAD MULTIPLEXING UNIT
Wheelbase &frame
(196 WHEELBASE
11/32 X 3 -1/2" X 10 -15/16 STEEL FRAME 120KSI
(75 REAR FRAME OVERHANG
.Chas §is`gtiipmen;
THREE -PIECE 14" CHROME STEEL BUMPER WITH
COLLAPSIBLE ENDS AND LEFT -HAND WING
CUTOUT FOR SPEAKER
FRONT TOW HOOKS FRAME MOUNTED
BUMPER MOUNTING FOR SINGLE LICENSE PLATE
CLEAR FRAME RAILS, NO PROTRUSIONS
IN /OUTBOARD BOTH RAILS BOC TO 30"
GRADE 8 THREADED HEX HEADED FRAME
FASTENERS
E
Fu el' 'ani<s
Tires
Hubs
Rosemount MN MWF
50 GAL RECTANGULAR ALUMINUM FUEL TANK RH
PLAIN ALUMINUM/PAINTED STEEL FUEL/
HYDRAULIC TANK(S) WITH PAINTED BANDS
FUEL TANK(S) FORWARD
FUEL TANK CAP(S)
EQUIFLO INBOARD FUEL SYSTEM
AUXILIARY FUEL SUPPLY AND RETURN PORTS
REINFORCED NYLON FUEL HOSE
GOODYEAR G159 12R22 5 16 PLY RADIAL FRONT
TIRES
GOODYEAR G286 315/80R22 5 20 PLY RADIAL REAR
TIRES
WABCO 4S/4M ABS WITHOUT TRACTION CONTROL
ENHANCEMENT
REINFORCED NYLON, FABRIC BRAID AND WIRE
BRAID CHASSIS AIR LINES
STANDARD BRAKE SYSTEM VALVES
RELAY VALVE WITH 5-8 PSI CRACK PRESSURE NO
REAR PROPORTIONING VALVE
BW AD -9 BRAKE LINE AIR DRYER W/HEATER
CUSTOM STEEL AIR BRAKE RESERVOIRS
BW DV -2 AUTO DRAIN VALVE, W/O HEATER WET
TANK
07/26/2005 9 55 AM
Page 4 of 8
:Cab Exterior
Gab lntecior
CONMET IRON FRONT HUBS
CONMET IRON REAR HUBS
22 5X8 25 10-HUB PILOT ALUMINUM FRONT
WHEELS
22 5X9 0 10-HUB PILOT ALUMINUM OUTER WHEELS
ISTL INNER
POLISHED FRONT WHEELS (OUTSIDE ONLY)
POLISHED REAR WHEELS OUTSIDE OF OUTER
WHEELS ONLY
106" BBC FLAT ROOF ALUMINUM CONVENTIONAL
CAB
AIR CAB MOUNTS
NFPA COMPLIANT EXTERIOR GRAB HANDLES
HOOD MOUNTED CHROMED PLASTIC GRILLE
FIBERGLASS HOOD
DUAL 25" ROUND GROVER STUTTER TONE AIR
HORNS, HOOD MOUNTED
DUAL ELECTRIC HORNS
ALL LOCKS KEYED THE SAME
REAR LICENSE PLATE MOUNT END OF FRAME
INTEGRAL HEADLIGHT/MARKER ASSEMBLY WITH
CHROME BEZEL
(5) AMBER MARKER LIGHTS
WIRING WITH SEPARATE STOP/TAIL WIRES
STANDARD FRONT TURN SIGNAL LAMPS
DUAL BRIGHT HEATED WEST COAST MIRRORS
DOOR MOUNTED MIRRORS
102" EQUIPMENT WIDTH
LH/RH 8" BRIGHT FINISH CONVEX MIRRORS
MOUNTED UNDER PRIMARY MIRRORS
STANDARD SIDE/REAR REFLECTORS
63"X14 TINTED REAR WINDOW
TINTED DOOR GLASS LH AND RH WITH TINTED
NON OPERATING WING WINDOWS
MANUAL DOOR WINDOW REGULATORS
TINTED WINDSHIELD
8 LITER WINDSHIELD WASHER RESERVOIR
WITHOUT FLUID LEVEL INDICATOR
OPAL GRAY VINYL INTERIOR
MOLDED PLASTIC DOOR PANEL
Rosemount MN MWF 07/26/2005 9 55 AM
Page 5 of 8
MOLDED PLASTIC DOOR PANEL
GRAY VINYL MATS WITH INSULATION
FORWARD ROOF MOUNTED CONSOLE WITH
UPPER STORAGE COMPARTMENTS WITHOUT
NETTING
IN DASH STORAGE BIN
(2) CUP HOLDERS, LH AND RH DASH
GRAY /CHARCOAL FLAT DASH
HEATER, DEFROSTER AND AIR CONDITIONER
MAIN HVAC CONTROLS WITH RECIRCULATION
SWITCH
STANDARD HEATER PLUMBING
SANDEN COMPACT AIR CONDITIONER
COMPRESSOR
BINARY CONTROL, R -134A
CAB INSULATION
SOLID -STATE CIRCUIT PROTECTION AND FUSES
12V NEGATIVE GROUND ELECTRICAL SYSTEM
DOME LITE W(3 -WAY SWITCH ACTIVATED BY LH
AND RH DOORS
CAB DOOR LATCHES WITH MANUAL DOOR LOCKS
(1) 12V POWER SUPPLY, IN DASH
BOSTROM TALLADEGA 910 HIGH -BACK AIR
SUSPENSION DRIVER SEAT
TWO -MAN MID -BACK TOOL BOX PASSENGER SEAT
LH /RH INTEGRAL DOOR PANEL ARM RESTS
VINYL WITH VINYL INSERT DRIVER SEAT
VINYL WNINYL INSERT, PASSENGER SEAT
NFPA COMPLIANT HIGH VISIBILITY SEAT BELTS
ADJUSTABLE TILT AND TELESCOPING STEERING
COLUMN
(18 LK FOUR -SPOKE CHARCOAL STEERING
WHEEL
DRIVER/PASSENGER INTERIOR SUN VISORS
7nsti uments Controls
BLACK GAUGE BEZELS
GRAY INSTRUMENT PANEL- DRIVER
LOW AIR PRESSURE LIGHT AND BUZZER
2" PRIMARY AND SECONDARY AIR PRESSURE
GAUGES
ENGINE COMPARTMENT MOUNTED AIR
RESTRICTION INDICATOR WITH GRADUATIONS,
WITH WARNING LIGHT IN DASH
87 DB TO 112 DB SELF ADJUSTING BACKUP ALARM
Rosemount MN MWF 07/26/2005 9 55 AM
Page 6 of 8
Desig
Rosemount MN MWF
CRUISE CONTROL ELECTRONIC ENGINE, WITH
SWITCHES IN LH SWITCH PANEL
KEY OPERATED IGNITION SWITCH AND INTEGRAL
START POSITION, 4 POSITION
OFF/RUN /START /ACCESSORY
ODO/TRIP /HOU R/DIAGNOSTICNOLTAGE
DISPLAY1X7 CHAR,26 WRNG LAMPS, DATA LINKED
ICU3
DIAGNOSTIC INTERFACE CONNECTOR, 9 PIN, SAE
J1587/170811939, LOCATED BELOW DASH
2" ELECTRIC FUEL GAUGE
ENGINE ECM CUSTOMER ACCESS CONNECTOR
MOUNTED BACK OF CAB, PARK BRAKE INTERLOCK
ELECTRICAL ENGINE COOLANT TEMPERATURE
GAUGE
2 TRANSMISSION OIL TEMPERATURE GAUGE
ENGINE AND TRIP HOUR METERS INTEGRAL
WITHIN DRIVER DISPLAY
ELECTRIC ENGINE OIL PRESSURE GAUGE
F/L XTA -2000 AM/FMNJB RADIO BY DELCO
DASH MOUNTED RADIO
(2) RADIO SPEAKERS (CAB ONLY)
AM/FM ANTENNA MOUNTED ON FORWARD LH
ROOF
ELECTRONIC MPH SPEEDOMETER WITH
SECONDARY KPH SCALE, WITHOUT ODOMETER
ELECTRONIC TACHOMETER 3000 RPM
IGNITION SWITCH CONTROLLED ENGINE STOP
DIGITAL VOLTAGE DISPLAY INTEGRAL WITH
DRIVER DISPLAY
SINGLE ELECTRIC WINDSHIELD WIPER MOTOR
WITH DELAY
MARKER LIGHT SWITCH INTEGRAL WITH
HEADLIGHT SWITCH
ONE VALVE PARKING BRAKE SYSTEM WITH
WARNING INDICATOR
SELF CANCEL TURN SIGNAL SWITCH WITH
DIMMER, WASHER VIPER AND HAZARD IN HANDLE
INTEGRAL ELECTRONIC TURN SIGNAL FLASHER
TWO COLOR CUSTOM PAINT
CAB COLOR A N0006HN WHITE IMRON 5000
CAB COLOR B. N4661 HN LIME GREEN PIERCE #40
IMRON 5000
07/26/2005 9 55 AM
Page 7 of 8
Weight Summary
Total Weight
Front Weight Total
Rear Weight Total
Total Weight
Weights shown are estimates only.
Rosemount MN MWF
6706 LBS
4040 LBS
10746 LBS
07262005 9 55 AM
Page 8 of 6
Standard:
Section 1: Booster Tank
Section 2: Booster Tank Piping, Fills, Gauges
Section 3: Dump Valves Chutes
Section 4: Portable Tank Carrier
Section 5: Apparatus Body and Components
Section 6: Apparatus Body Compartments
Section 7: Running Boards, Catwalks, Rear Step
Section 8: Grab Rails Foot Steps
Section 9: Electrical Equipment
Section 10: Emergency Siren Lighting Equipment
Section 11: Painting, Lettering, Striping, and Signs
Section 12: Rust Proofing Mud Flaps
Section 13: Pump Plumbing
Section 14: Hose Trays, Cross Lays, Pre connects
Section 15: Hard Suction Ladder Carriers
Section 16: Hose Reel
Section 17: Chassis Accessories
Section 18: Chassis
Section 19: Loose Equipment
Initial:
Date:
Rosemount Fire Dept.
Rosemount, MN
FS Series
2,500 Gallon Tanker
Specifications
INDEX To Specifications
Rosemount Fire Dept.
Rosemount, MN
STANDARD
Section 1: Booster Tank
1.00
The 2500 gallon baffled elliptical tank shall be designed to
minimize the height of the center of gravity while maximizing the
maneuverability of the vehicle. The elliptical tank shall be
constructed of 10 and 7 gauge mild steel. The inner tank and swash
partitions shall be 100% laminated by hand with resins, 2 layers
of 1.5 oz. fiber matting, and top- coated with 2 coats of gelcoat.
This process provides a flexible, non flaking, and non rusting
fiberglass tank within the existing tank.
LIFE TIME WARRANTY WITH NO PRO -RATE
1.01
Shell of the booster tank shall be made of 10 -gauge fiber /steel.
1.02
Heads of the booster tank shall be made of 7 -gauge fiber /steel.
1.03
The swash partitions shall be so designed to insure maximum surge
resistance when starting and stopping and allow for the maximum
flow of water to the dump valve(s). This baffling system shall be
fully compliant with NFPA and the Department of Transportation
regulations.
1.03.1
Longitudinal swash partition shall be provided to minimize side
to -side surge within the tank and allow for the maximum flow of
water to the dump valve(s). The Longitudinal swash partition shall
be centered and extend the full length of the tank. This baffling
system shall be fully compliant with NFPA and the Department of
Transportation regulations.
1.04
The entire sub frames of the booster tank shall be made of 7 -gauge
carbon steel. The entire sub -frame assembly shall be primed and
undercoated with a corrosion preventative undercoating. The tank
sub frames shall rest on rubber sills portioned between the tank
sub frames and chassis frames.
Initial:
Date:
2
1.05.01
Two (2) 6" diameter internal vent /overflows will be provided. The
vent /overflows shall be separate from the manhole so that they do
not obstruct the manhole opening. The vent /overflows shall be
specially designed to prevent the creation of a vacuum within the
tank while dumping the water via the dump valves. The
vent /overflows will discharge excess spillage below the tank by
use of internal piping within the tank.
Rosemount Fire Dept.
Rosemount, MN
1.06
Manhole shall be 20" in diameter with a 10" flip lid cover located
at the rear of the tank. The flip lid must be capable of being
manually unlatched for additional overflow from the tank if the
water flow would exceed the internal vent capacity.
Initial:
Date:
Section 2: Booster Tank Piping, Fills, Gauges
2.00
Flanges, there shall be one (1) 2 1/2" NPT tank flange opening and
plug located under the tank.
2.04
Direct fill, one (1) 4" direct fill with Storz fitting, and gated
with a 4" butterfly valve shall be provided at the rear of the
apparatus on the left side of the rear dump valve. The direct fill
shall be equipped with a 4" cap and chain.
2.04.3
4" 30- degree elbow, direct fill shall be equipped with a 4" Storz,
30- degree elbow fitting.
2.10.1
One (1) MC Products, "Always On 4 Light tank level gauge with
ignition off display will monitor the water tank level and be
located on the outside of the pump compartment. The tank sensing
probe shall be made of stainless steel in a chemical resistant PVC
housing.
2.10.3
One (1) second "readout" MC Products 4 Light tank level gauge will
monitor the water tank level and be located on the rear of the
apparatus.
Initial:
Date:
Rosemount Fire Dept.
Rosemount, MN
2.11
Spanner and hydrant wrenches, there shall be two (2) wrench sets.
Each set shall have an adjustable hydrant wrench, two (2) spanner
wrenches, and holder. Wrenches shall be installed per customer
instructions.
Section 3: Dump Valves Chutes
3.00.1
Rear dump valve, one (1) Newton 10" square Kwick -Dump valve, model
1050 shall be provided at the rear center of the tank. The rear
dump valve shall be equipped with a Newton 36" telescoping chute,
model 4036, and painted the exterior color of the apparatus.
3.02
Side dump valve, one (1) Newton 10" square Kwick -Dump valve, model
1060 shall be provided at the front driver's side of the
apparatus. For improved water flow, the dump valve shall be
attached directly to the tank and not by the use of a rear
manifold system. The side dump valve shall be equipped with a
Newton 36" telescoping chute, model 4036, and painted the exterior
color of the apparatus.
Section 4: Portable Tank Carrier
4.01
Tip down portable tank carrier, one (1) tip down portable tank
carrier for loading /unloading of a folding water tank shall be
located on the passenger's side and above the catwalk. The tank
carrier shall be designed to fold down over the body side. When in
the up position the tank carrier shall be secured with heavy duty
locking DeStatco latches. The tank carrier shall be made of 1 1/4"
14 -gauge stainless steel square tubing. The tank carrier shall be
large enough to hold at least a 2,500- gallon size folding water
tank. To help keep the wind from entering the folding water tank
when in the traveling position, there shall be a wind deflector
shield made of 1/8" polished aluminum Tread -Brite installed on
front of the portable tank carrier. There shall be one (1) 24"
vertical grab rail installed on front of the portable tank
carrier. The grab rail shall be made of 1 1/4" diameter extruded
aluminum tubing with ribbed rubber inserts and chrome plated
stanchion brackets.
4
Rosemount Fire Dept.
Rosemount, MN
4.02.1
Portable tank, there shall be one (1) 2,500 Gallon portable tank
and aluminum frame supplied. Liner shall be yellow in color and
made of 23 oz. durable nylon coated material.
Section 5: Apparatus Body and Components
5.00
The entire apparatus body must be removable in its completed
entity and accompany the water tank when the water is removed. All
compartment and lower body panels are to be attached to the
structural tank sub frames and tank catwalks. The entire apparatus
body shall be constructed of 12 and 14 -gauge smooth carbon steel.
10 YEAR WARRANTY ON PAINTED BODY PARTS
5.01
Fenders shall be integral with the side of the body. Fender wells
shall be constructed with full circular inner liners for ease of
cleaning and maintenance.
5.02
There shall be bright polished aluminum fenderettes installed on
the wheel wells to prevent splash and to give the body a pleasing
appearance. The fenderettes shall extend approximately 1" beyond
the body side. The fasteners shall not be exposed to the exterior
of the fenderettes.
5.03
The bottom edge of the entire apparatus shall have a 3" by 1"
polished aluminum Tread -Brite rub -rail installed to give the body
a pleasing appearance.
5.04
Tow eye, there shall be one (1) tow eye located above rear step
and attached directly to the frame on the left side of the rear
dump valve.
Initial:
Date:
5
Rosemount Fire Dept.
Rosemount, MN
Section 6: Apparatus Body Compartments
6.00
Compartment, one (1) "sweep out" style compartment shall be
provided on the driver's side and ahead of the rear wheels. The
compartment shall have approximate inside dimensions of 76" wide
by 34" tall by 27" deep. The compartment shall have a 68" ROM
Roll- o -matic aluminum roll up door paint to match the apparatus
color, two (2) door activated compartment lights, two (2)
stainless steel louvered vents, black Turtle Tile plastic dry
decking, and floor drains. The interior of the compartment shall
be sprayed with white Speedliner bed coating and spatter painted
the exterior color of the apparatus.
6.01
Compartment, one (1) "sweep out" style compartment shall be
provided on the passenger's side and ahead of the rear wheels. The
compartment shall have approximate inside dimensions of 94" wide
by 34" tall by 27" deep. The compartment shall have a 68" ROM
Roll- o -matic aluminum roll up door painted to match the apparatus
color, two (2) door activated compartment lights, two (2)
stainless steel louvered vents, black Turtle Tile plastic dry
decking, and floor drains. The interior of the compartment shall
be sprayed with white Speedliner bed coating and spatter painted
the exterior color of the apparatus.
6.10.2
Compartment dividers, there shall be three (3) upright compartment
dividers installed in the passenger's side compartment. Dividers
shall be made from smooth aluminum, mounted on Unistrut and shall
be adjustable.
Section 7: Running Boards, Catwalks, Rear Step
7.01
The catwalks shall be located above the left and right
compartments. The Catwalks shall be made of polished aluminum
Tread -Brite and bent at a 30- degree angle to provide a drip rail.
7.02
For a safer walking surface, the rear step shall be NFPA compliant
and made of serrated aluminum "Grip Strut Safety Grating The
outside edge of the rear step shall have a 3" by 1" polished
aluminum Tread -Brite rub -rail installed to give the step a
pleasing appearance. The rear step shall be 15" deep with a 12"
tall "kick" plate.
Initial:
Date
6
8.00
Grab rails, there shall be two (2) 20" vertical grab rails
provided at rear of tank, one each side. The grab rails shall be
made of 1 1/4" diameter extruded aluminum tubing with ribbed
rubber inserts and chrome plated stanchion brackets.
8.00.1
Grab rail, there shall be one (1) 20" horizontal grab rail
provided on the upper left side of tank, below manhole for ease of
overhead filling. The grab rails shall be made of 1 1/4" diameter
extruded aluminum tubing with ribbed rubber inserts and chrome
plated stanchion brackets.
8.01
Foot steps, there shall be two (2) large chrome plated folding
steps with a minimum of 35" square of surface and polished
aluminum Tread -Brite kick plates provided at rear of body, one (1)
each side, for access to the catwalk area.
9.00
Battery master switch, a single "on /off" position master battery
switch shall be mounted in the cab. When in the off position, all
electrical power to the apparatus shall be disconnected. There
shall be a green pilot light, visible to the driver, which
illuminates when the master switch is activated.
9.00.1
The body and chassis shall be wired as independent modules and
connected as a completed unit at the final assembly via electrical
connectors located in the electrical compartment. Seals shall be
provided on each individual wire and the assembly as a whole. All
wiring for the apparatus body shall be within a temperature
resistance harness. All wires in each harness shall be color
coded. Wiring shall be run along structural rails and tied in a
neat and orderly manner.
Initial:
Date:
Rosemount Fire Dept.
Rosemount, MN
Section 8: Grab Rails Foot Steps
Section 9: Electrical Equipment
Rosemount Fire Dept.
Rosemount, MN
9.00.2
The electrical junction box for all apparatus connections, relays,
circuit breakers, etc., will be located in the face of the forward
passenger side compartment. It shall be of polished aluminum
Tread -Brite construction with an aluminum hinge. The apparatus
circuits requiring load protection shall utilize sealed relays and
automatic reset circuit breakers.
9.01
Clearance lights with chrome plated guards, there shall be a total
of seven (7), five (5) red lights installed on the rear of the
apparatus, and two (2) amber lights installed on the front left
and right of the apparatus.
9.02
Reflectors shall be installed per Department Of Transportation
specifications.
9.03.1
Two (2) Weldon model 4694 Quad- Cluster combination red stop /tail,
clear backup light, amber arrow type turn signal, and red warning
light assemblies shall be supplied and installed on the rear of
the apparatus. Individual lights shall measure 6" wide by 4" tall.
Light assemblies shall be provided in a polished cast aluminum
housing measuring 8 3/4" wide by 19 7/8" tall. Each light assembly
shall be installed using a gasket between the casting and body.
9.05
Compartment lights, there shall be two (2) door activated
compartment lights installed in each compartment.
9.06
Compartment "door ajar" warning light, there shall be a "red pilot
light visible to the driver which illuminates when a compartment
door is open.
Initial:
Date:
8
Rosemount Fire Dept.
Rosemount, MN
Section 10: Emergency Siren Lighting Equipment
10.00
Control Center, all accessory and emergency lighting shall be
controlled at a master control center in the cab. The control
center shall contain lighted rocker switches and shall be heavy
duty rated to service the maximum imposed electrical load. The
control center shall have lighted identification plates on a non
glare panel face that clearly identify each switch and its
function. The control center shall control all warning lights,
scene lights, and include the "Master On" and "Open Door"
indicator lights.
10.01
Light bar, the upper level warning package shall be fully NFPA
compliant and shall be certified by the lighting component
manufacture to meet all requirements. The front and front side
zones shall be covered by one (1) Code 3, model 556A3, 56" long
light bar mounted on the cab roof. The outer sections of the light
bar shall each have two (2), 50 -watt halogen rotator and a diamond
mirror. The center section of the light bar shall have a 50 -watt
halogen rotator with 3 -step cascade mirrors. The entire light bar
shall have clear lenses with red filters on the two outside
rotators and the center rotator. Activation of the light bar shall
be via the control center located in the cab.
10.02
Siren, one (1) Code 3, model 3692 V -Con, siren control head shall
be mounted in the chassis cab in a location convenient to the
driver. The siren control head shall have electronic air horn,
public address mode, wired noise canceling microphone and contain
electronic siren tones of wail, yelp, and hi -lo. The siren control
head shall be lighted for easy night operation.
10.03
Speaker, one Cast Products 100 -watt polished aluminum siren
speaker shall be mounted either below the front bumper, or through
the bumper depending on the configuration of the chassis bumper.
Initial:
Date:
Rosemount Fire Dept.
Rosemount, MN
10.04.1
Flashing lights, the lower level warning package shall be fully
NFPA compliant. The front zone to be covered by two (2) Weldon,
model 4612, and flush mounted flashers with chrome bezels and red
lenses. These lights shall be 6" wide by 4" tall and be mounted on
the chassis grille. The rear zone to be covered by two (2) Weldon,
model 4611 flush mounted flashers with red lenses. These lights
shall be 6" wide by 4" tall and be mounted on the rear Weldon,
model 4694, Quad Cluster combination red stop /tail, clear backup
light, and amber arrow type turn signal assemblies.
10.05
Rotators, the upper level warning package shall be fully NFPA
compliant and shall be certified by the lighting component
manufacture to meet all requirements. The rear and rear side zones
shall be covered by two (2) Code 3 model 550, 50 -watt halogen fast
rotators with a red and a blue lens. The two (2) rotators shall be
positioned at the rear corners of the apparatus. Activation of the
rotators shall be via the control center located in the cab.
10.06
Intersection lights, the lower level warning package shall be
fully NFPA compliant and shall be certified by the lighting
component manufacture to meet all requirements. Two (2) Weldon,
model #3812, halogen flashers with red lenses shall cover each of
the side zones. These lights shall have approximate dimensions of
7" long by 3" tall. One of the lights shall be mounted at the rear
of the body, and one shall be mounted on the front corner of the
chassis for use as an intersector style light.
10.07
Scene lights, there shall be six (6) Weldon model #7812, 50 -watt
internal optic scene lights mounted two (2) at rear, two (2) on
driver's side, and two (2) on passenger's side. The lights shall
be controlled from three (3) individual switches on the control
center located in the chassis cab.
10.08
Backup alarm, there shall be a backup alarm installed. Alarm shall
be energized automatically when the chassis is placed into
reverse.
Initial:
Date:
10
Rosemount Fire Dept.
Rosemount, MN
10.09
Ground lights, there shall be four (4) ground lights installed to
illuminate the area below the apparatus. Two (2) lights shall be
installed below left and right front body, and two (2) lights
shall be installed below left and right rear step area. Grounds
lights shall be activated when parking brake is applied.
10.12
Opticom, there shall be an Opticom, model #M -492H installed on the
chassis cab. The Opticom shall be controlled by a switch, model
#M -793B and shall be deactivated when parking brake is applied.
Section 11: Painting, Lettering, Striping, and Signs
11.00
All components shall be back primed prior to assembly.
11.01
The entire tank, body, and components will be sandblasted, sanded,
cleaned, etched and primed with PPG NCP270 direct to metal primer
filler.
11.02
The apparatus body will be hand sanded and be painted one (1)
color with PPG Deltron base coat /clear coat paint to match the
chassis paint color. A two (2) ounce container of touch -up paint,
with applicator brush, shall be supplied for each color of the
finished apparatus body paint upon completion of the apparatus.
11.03
Compartments, the interior of the compartments shall be sprayed
with white Speedliner bed coating and spatter painted the exterior
color of the apparatus.
11.04
Graphics package, a graphics package from the Graffix Shop in
Eagan MN, that matches the existing trucks of the Rosemount Fire
Department, shall be provided and installed. The graphics package
shall include all of the lettering and striping. The Rosemount
Fire Department shall approve the graphics package before
installation.
Initial:
Date:
11
12.00
Undercoating, there shall be an emulsion type, latex base,
undercoating applied to all under surfaces of the apparatus.
12.01
All fasteners used in securing components on or to the body shall
be stainless steel.
12.02
Mud flaps, there shall be two (2) mud flaps installed on rear of
apparatus behind the rear wheels.
12.03
Sealing and caulking, all edges of polished aluminum Tread -Brite
components including rear step, catwalks, and kick plates shall be
caulked with aluminum silicone caulk to seal and to give it a
pleasing appearance.
13.05
The pump shall be a Waterous, model PB18- 3030C, engine driven
pump. Pump features include a high- strength aluminum alloy volute
body and head, anodized for superior corrosion resistance. The
impeller shall be constructed of a high strength corrosion
resistance bronze, and fully enclosed. The impeller shaft shall be
made of stainless steel and a stainless steel shaft seal.
13.05.1
The engine shall be a four cycle air cooled 18 HP Briggs and
Stratton, model 350447, Vanguard V -Twin engine, with integral fuel
pump, 12 -volt electric start, and manual start. The fuel will be
connected to a 6- gallon marine style fuel tank located on drivers
side running board when available, and shall be enclosed in an
aluminum Tread -Brite compartment with hinged cover for easy
access. If a running board is not available, the 6- gallon marine
style fuel tank will be mounted in a tray and located in the pump
compartment.
Initial:
Date:
Rosemount Fire Dept.
Rosemount, MN
Section 12: Rust Proofing Mud Flaps
Section 13: Pump Plumbing
Pump Ratings: 100 GPM 110 PSI
400 GPM 15 PSI
12
Rosemount Fire Dept.
Rosemount, MN
13.05.2
A pump control panel shall be provided and attached to the pump
unit. The pump control panel shall include an ignition switch,
starter button, stop button, engine throttle, and pressure gauge.
The pump primer shall be a combination vacuum type exhaust primer
and a spark- arresting muffler.
13.05.3
The pump shall be permanently mounted in the driver's side front
compartment with Roll -o -matic anodized aluminum roll up doors for
pump operation and service. The engine compartment will have an
oil drain access in the floor for ease of changing the pump engine
oil.
13.05.4
Tank to pump line, there shall be a 2 1/2" tank to pump line
provided from the water tank to the pump. The line shall have a
2 1/2" Akron Full -Flow swing out valve with galvanized piping and
victaulic coupling. The flex connections installed between the
pump and water tank shall give the plumbing system flex, thus
minimizing stress on the line. A "tee" handle provided in the pump
compartment shall control the valve.
13.05.5
Tank fill /pump re- circulating line, there shall be a 1 1/2" tank
fill /pump re- circulating line provided from the pump to the water
tank. The line shall have a 1 1/2" Akron Full -Flow swing out valve
with 1 1/2" high pressure flexible hose. The flex connections
installed between the pump and water tank shall give the plumbing
system flex, thus minimizing stress on the line. A "tee" handle
provided in the pump compartment shall control the valve.
13.05.6
Pump drain, there shall be one (1) pump drain provided to drain
the suction side of the pump. The pump drain shall be controlled
from a control handle located directly below the pump compartment.
13.05.7
Suction(s), there shall be one (1) 3" suction pipe provided at the
pump for drafting or direct fill. The suction shall be equipped
with a 3" NPT male X 2 1/2" NST female chrome plated swivel
adapter with screen, and a 2 1/2" chrome plated plug and chain.
13.05 8
Discharge(s), there shall be one (1) 2 1/2" NST male discharge
pipe provided at the pump. The discharge shall be equipped with a
2 1/2" chrome plated cap and chain.
Initial:
Date:
13
Rosemount Fire Dept.
Rosemount, MN
Section 14: Hose Trays, Cross Lays, Pre- connects
14.04
Rear hose compartments, there shall be one (1) hose compartment
with vinyl cover located at the center of the rear step and below
the rear dump valve. The hose compartment shall be large enough to
hold approximately 50' of soft suction for the direct tank fill.
The hose compartment shall have a hinged back panel, be open to
the top, be made of aluminum Tread Brite, include floor drains,
and have rubber floor tiles.
Section 15: Hard Suction Ladder Carriers
15.01
Hard suction trays, there shall be one (1) double wide aluminum
Tread -Brite hard suction hose tray located on driver's side above
the catwalk, and on the side of tank. The hose tray shall be
capable of holding two (2) sections of 2 1/2" X 10' hard suction
hose.
15.01.5
Hard suction trays, there shall be two (2) 6" X 10' aluminum
Tread -Brite hard suction hose trays to be located on driver's side
above the catwalk, and on the side of tank.
15.05
There shall be two (2), 2 1/2" X 10', PVC flexible hard suction
hoses provided.
15.05.5
There shall be two (2), 6" X 10', PVC flexible hard suction hoses
provided.
Section 16: Hose Reel
16.00
There shall be one (1) Hannay electric rewind hose reel with 100'
of 1" booster hose and hose roller installed in driver's side
compartment. Hose reel shall be gated with an Akron 1" Full -Flow
swing out valve. Valve to have a "tee" handle control in the pump
compartment. The hose reel shall have an Akron, model #1702,
pistol grip nozzle attached.
Initial:
Date:
14
Initial:
Date
Section 17: Chassis Accessories
17.01.1
Aluminum chassis overlays, the M2 Freightliner chassis steps shall
be overlaid with aluminum Tread Brite. Chassis step overlay shall
be approximately 8" deep.
17.04.1
Air auto eject plug -in, there shall be one (1) Kussmaul Super Auto
Eject, model #091 -28, for air connection shall be installed.
17.05
Wheel chocks, there shall be two (2) wheel chocks with holders
installed, under body on driver's side of apparatus.
Section 18: Chassis
Rosemount Fire Dept.
Rosemount, MN
18.01
2006 M2 Freightliner chassis, two tone paint, 330HP Caterpillar
diesel motor, Allison automatic transmission, 14,600# Front
30,000# rear axle rating, aluminum wheels, and air conditioning.
See attached specs for complete description.
Section 19: Loose Equipment
19.00
Barrel strainer, there shall be one (1) Kochek, model BS25C,
2 1/2" barrel strainer supplied.
19.01
Low level strainers, there shall be two (2) Kochek, model LL60, 6"
low level strainers supplied. Strainers shall be equipped with an
internal screen and jet siphon attachment.
19.02
Flashlights, there shall be two (2) Streamlight, model SL2OXPLED
flashlights supplied. Flashlights shall be yellow in color and
shall be connected to the 12 volt electrical system.
19.03
Adapters, there shall be two (2) Kochek, model S54R, 4" Storz X
2 1/2" NST female swivel adapters supplied.
15
Initial:
Date:
Rosemount Fire Dept.
Rosemount, MN
19.04
Adapter, there shall be one (1) Kochek, model S60S, 4" Storz X 5"
Storz adapter supplied
14
Dated this 6th day of September, 2005.
BY ORDER OF THE CITY COUNCIL.
CITY OF ROSEMOUNT
ADVERTISEMENT OF BID
Fire Tanker Vehicle
Notice is hereby given that sealed bids will be received by the City of Rosemount until 5:00 p.m.
on October 11, 2005 and will then be publicly opened and read aloud. Bids are being requested
for a fire tanker vehicle with specific equipment and devices as put forth in the specifications.
Specifications may be obtained through the office of the City Clerk, City of Rosemount, 2875
145 St. W., Rosemount, MN 55068.
All bids shall be made on forms from the office of the City Clerk, which will be furnished free,
to each bidder upon his request.
All bids must be sealed, marked "Bids for Fire Tanker Vehicle" and addressed to the City Clerk.
Each bid shall be accompanied by a certified check, cashier's check, or bid bond in the amount
of five (5 percent of the total bid price, made payable to the City of Rosemount.
The City of Rosemount reserves the right to reject any and all bids and to accept the bid it feels is
in the best interest of the community.
Linda J. Jentink, City Clerk
City of Rosemount
Dakota County. Minnesota
Auxiliary aids and services are available Please contact the City Clerk at 651- 322 -2003 or
651- 322 -6219 (TDD number) to make a request Examples of auxiliary aids or services may
include sign language interpreter, assistive listening kit, accessible meeting locations, etc.
Proposed schedule:
To City Council Sept. 6, 2005 to authorize bid
Publish Ad for Bid Sept. 9, 2005 in Rosemount Town Pages
Open Bids October 11, 2005, 5:00 p.m. at City Hall
Award Contract at City Council October 18, 2005