Loading...
HomeMy WebLinkAbout6.c. Request by Public Storage for a Major Amendment to the Secure Mini Storage Planned Unit Development EXECUTIVE SUMMARY Planning Commission Meeting: April 24, 2018 Tentative City Council Meeting: May 15, 2018 AGENDA ITEM: Case 18-20-AMD Request by Public Storage for a Major Amendment to the Secure Mini Storage Planned Unit Development AGENDA SECTION: Public Hearing PREPARED BY: Anthony Nemcek, Planner AGENDA NO. 6.c. ATTACHMENTS: Site Location Map; Existing Conditions Survey; Secure Mini Storage Master Development Plan; Site Plan; Grading Plan; Utility Plan; Photometric Plan; Landscape Plan; Architectural Elevations; Engineer’s Memo dated April 17, 2018; Minutes from May 12, 1998 Planning Commission Meeting; Planning Commission Packet from May, 12, 1998 APPROVED BY: K.L. RECOMMENDED ACTION: Motion to recommend the Council Approve the Major Amendment to the Secure Mini Storage Planned Unit Development to Construct an Enclosed Self Storage Facility, subject to the following conditions: 1. Provision of a landscape surety in the amount of $1,980 2. Approval and recording of an updated easement agreement for the drainage and utility easement located interior to the site 3. Selection and placement of the rooftop mechanical equipment so that the parapet wall shields the equipment from public view 4. Non-essential lighting shall be turned off after business hours 5. Approval of a sign permit application for any new signage on the site 6. Provision of a $50,000 bond or letter of credit for work to connect to city utilities within Chippendale Avenue 7. Payment of $45,355.51 for offsite ponding 8. Conformance with all requirements of the City Engineer as detailed in the Engineer’s Memo dated April 17, 2018 SUMMARY Applicant: Public Storage Property Owner: Secure Mini Storage Limited Partnership Location: 15854 Chippendale Avenue Area in Acres: 5.3 Acres Comp. Plan Designation: BP-Business Park Current Zoning: BP-Business Park 2 Public Storage is requesting a Major Amendment to the Secure Mini Storage planned unit development to construct a 122,691 square foot enclosed self-storage facility at the location of the Public Storage self- storage site located at 15854 Chippendale Avenue. The new building will contain storage units as well as an office and a parking bay for enclosed loading and unloading. Staff is recommending approval of the Major Amendment. BACKGROUND The subject property has been the site of a self-storage facility since the planned unit development agreement and master development plan for the site was approved and the current facility constructed in 1998. The original PUD indicated six future storage buildings on the development site similar in style to the existing buildings on the site. The proposed amendment to the PUD would eliminate the exterior- style storage buildings with a single enclosed structure. At the time of the original PUD approval, a deviation from the building setback standard of 30 feet from the rear property line was granted. The proposed building being reviewed with the current amendment request meets the City Code’s rear yard setback requirements so no deviation from the setback standards is required. The building elevations provided by the applicant indicate that, in addition to masonry finishes and architectural accents, EIFS will be used for a significant portion of the exterior surfaces. EIFS is generally not permitted, and its use would be a deviation from the City Code included in the PUD amendment. In comparison to the existing buildings the new structure is a significant improvement and much more consistent with current ordinance standards. Approximately 50% of the building will feature various brick face finishes and staff finds that the architectural plans submitted acceptable. Staff is recommending approval of the Major Amendment to the Secure Mini Storage Planned Unit Development, subject to conditions. MAJOR AMENDMENT TO THE PUD AGREEMENT Amendments to approved master development plans may be approved by the City Council following review by the planning commission. The notification and public hearing procedure for a Major Amendment is the same as that of the original approval. An amendment is determined to be major if it: 1. Substantially alters the location of buildings, parking areas or roads. 2. Increases or decreases the number of residential dwelling units by more than five percent (5%). 3. Increases the gross floor area of nonresidential buildings by more than five percent (5%) or increases the gross floor area of any individual building by more than ten percent (10%). 4. Increases the number of stories of any building. 5. Decreases the amount of open space by more than five percent (5%) or alters it in such a way as to change its original design or intended use. 6. Creates noncompliance with any special condition attached to the approval of the master development plan. In this case, the proposed project increases the gross floor area by more than five percent, increases the number of stories, and decreases the amount of open space by more than five percent. Therefore, the proposed project requires a major amendment to the Secure Mini Storage Planned Unit Development agreement. SITE PLAN REVIEW Building Massing and Materials The applicant has submitted plans detailing the exterior building elevations. The building is largely a rectangular structure with a parapet at the northwest corner of the building featuring extensive glazing. This is the access to the office and the front of the building, facing the residential homes across the street. The exterior surfaces of the building are earth tones with the exception of architectural details that are 3 orange in color. The surface materials are a combination of facebrick and EIFS. The facebrick is along the bottom of the building for visual weight and extends upward at regular intervals giving a column effect. The non-masonry material is EIFS which is not permitted in the BP Business Park zoning district, so a deviation from the City Code is requested by the applicant. Similar to other recent projects there is development on the site which does not comply with current standards. The next phases of development should be upgraded from the current standard but may not comply with all ordinance criteria. In this instance the more public views have significantly upgraded materials as compared to the other existing storage buildings. Staff believes the design and materials are consistent with the intent of the ordinance design requirements and can support the deviation. The north side of the building includes an enclosed vehicle bay that allows customers to load and unload in an enclosed area that is protected from the elements and offers a degree of security. The bay features exterior finishes that match the rest of the building as well as transparent garage doors. Setbacks The project meets all the setback requirements for the BP zoning district, including the required additional setback for properties adjacent to railroads and along collector streets. The building itself is 42.07 feet from the rear lot line that is adjacent to the railroad. The proposed front yard setback is 77.38 feet and the side yard setback to the north of the building is 271 feet. The driveway/parking areas also meet the setback requirements for the BP zoning district. Setback Standard Increased Setback Total Setback Required Proposed Front 30 feet 10 feet 40 feet 77.38 feet Side 10 feet 20 feet 30 feet 271 feet Rear 10 feet 30 feet 40 feet 42.07 feet Drives/Parking, Front 20 feet n/a 20 feet 47 feet Drives/Parking, Rear 10 feet n/a 10 feet 10 feet Drives/Parking, Side 10 feet n/a 10 feet 208 feet Parking The City Code parking requirement for self-storage facilities is one parking stall for every 6,000 square feet of storage space. The applicant anticipates the maximum area of storage space within the building to be 75% of the overall square footage, or 85,883 square feet. Therefore, a total of 15 parking spaces are required. The plans provided by the applicant show 14 exterior parking stalls, two of which are van- accessible, and an additional 6 stalls within the interior loading area for a total of 20 parking stalls. This amounts to 1 parking stall for every 4,294 square feet of storage area. Landscaping The application materials include a landscaping plan that meets the City Code requirements for the BP- Business Park zoning district. Specifically, the code requires one over story tree for every 3,000 square feet of land area and 1 foundation planting for every 10 linear feet of perimeter fencing. The landscaping plan indicates a total of 30 trees and 86 shrubs. There are currently a large number of trees along the northern boundary of the site. These trees and trees along the boulevard will remain. Six new over story trees will be planted in the grassy areas around the building, and one tree will be planted in the boulevard. Most of the foundation shrubbery will be located along the perimeter fence and around the proposed monument sign with some shrubbery located near the trash enclosure and the entrance to the building. A condition requiring the provision of a landscaping surety in the amount of $1,980 ($300x 6 trees plus 10%) is included in the recommendation. The landscape plans also indicate that the development will be under the maximum lot coverage for the BP zoning district. City Code allows no more than 75% of the site to be covered with impervious surfaces. The proposed improvements will result in a lot coverage percentage of 41.2%, leaving ample room for 4 future improvements if needed. Trash Enclosure The plans indicate that a trash enclosure will be provided just to the east of the majority of the parking. The enclosure will be constructed of material that meets the City Code requirements and of a color that matches the exterior of the proposed building. Lighting Site lighting will be provided by units mounted on the exterior building walls. The applicant has included a photometric plan that indicates the lighting meets the requirements of the City Code, no more than 0.5 lumens at any residential property line or 1.0 lumen at any nonresidential property line. Additionally, all lighting fixtures detailed in the plans are designed to direct light toward the ground. All nonessential lighting will be turned off after business hours, in accordance with City Code. Traffic Circulation The plans indicate that an additional entrance will be located at the intersection of Chippendale and 158th Street West approximately 325 feet north of the existing entrance. A 26’ wide drive lane will be located around the entire building. A six foot high, steel tube perimeter fence is proposed around the eastern portion of the building and surface parking/driveway with two gates to allow ingress and egress for both customers of the storage facility and also emergency vehicles. Engineering The City’s project engineer has reviewed the plans provided by the applicant. Comments by the project engineer are contained in the Engineer’s Memo dated April 17, 2018. The plans provided indicate a stormwater detention pond will be located in the northwest corner of the development site. Geronime Pond to the west of the site has been designed to accommodate the stormwater requirements for the site, rendering the proposed pond unnecessary except to manage discharge rates into the stormwater system. Changes to the grading plan to reduce the size of the ponding can be updated with the grading permit application. Other comments from the engineer relate to the location of sewer and water connections along Chippendale Avenue. RECOMMENDATION Based on the information provided by the applicant and reviewed in this report, staff is recommending approval of the Major Amendment to the Secure Mini Storage Planned Unit Development to allow construction of an enclosed self-storage facility, subject to conditions. PUBLIC STORAGE SITE AREA = 5.22 AC CANOPY = 2,149 SF FOOTPRINT = 40,897 SF 3 STORIES TOTAL BUILDING = 122,691 SF FFE = 947.00 5' GRID OFFICE T LOBBY G G UT UTUT UT 6 NOPARKING6 XXXX XXXXXXXXXXXXXXXXXXXX201.3 66.445.0 20.0 25.0 20.7 60.7201.3 66.4131.4concreteblockbuildingconcreteblockbuilding15854 Chippendale Avenue Rosemount,Minnesota concrete block building 13,366 sq. ft.HC TP G TP GM S S ST ST S S S S S S ST SS CO S CHIPPENDALEAVENUE(100'R.O.W)S00LINERAILROAD(100'R.O.W)EXISTING MULTIFAMILY EXISTING STORAGE FACILITY 1 2 TYP 2 TYP 2 TYP 2 TYP 3 3 4 4 4 5 5 6 6 7 7 8 9 11 11 11 12 13 14 15 TYP 15 TYP 16 16 17 17 17 17 17 17 19 19 15 22 21 22 2121 23 24 60'DRAINAGEANDUTILITYEASEMENT20 80'BUILDINGSETBACK30'BUILDINGSETBACK REDEVELOPMENT AREA 62.61'BUILDING SETBACK REDEVELOPMENT AREA REDEVELOPMENT AREA REDEVELOPMENT AREA SITE LEGEND EXISTING EASEMENT 1 PROPOSED CONCRETE PAVING X PROPOSED TRASH ENCLOSURE CONCRETE PAVING EXISTING FIRE HYDRANT SITE PLAN C1.1 LEGAL DESCRIPTION THAT PART OF THE SOUTH HALF OF THE SOUTHWEST QUARTER LYING WEST OF STATE TRUNK HIGHWAY NO. 3, EXCEPTING THEREFROM THE RIGHT-OF-WAY OF THE CHICAGO, MILWAUKEE, ST. PAUL, AND PACIFIC RAILROAD COMPANY (NOW CALLED SOO LINE RAILROAD), ALL IN SECTION 32, TOWNSHIP 115, RANGE 19, ACCORDING TO THE UNITED STATES GOVERNMENT SURVEY THEREOF AND SITUATED IN DAKOTA COUNTY, MINNESOTA. ABSTRACT PROPERTY. BASIS OF BEARING THE DAKOTA COUNTY COORDINATE SYSTEM (NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT) AS SHOWN HEREON. BENCHMARK MNDOT 1921 S IN ROSEMOUNT, AT THE JUNCTION OF TRUNK HIGHWAY 3 AND COUNTY ROAD 42 IN ROSEMOUNT, AT TRUNK HIGHWAY 3 MILEPOINT 32.45, 62.1 FEET NORTHWEST OF TRUNK HIGHWAY 3, 83.1 FEET SOUTH OF EASTBOUND COUNTY ROAD 42 FOG LINE OF TURN LANE, 6.1 FEET SOUTHEAST OF CHAIN LINK FENCE, 5.6 FEET SOUTHEAST OF A WITNESS POST. ELEVATIONS = 958.427 FEET (NAVD 88) CAUTION - NOTICE TO CONTRACTOR 1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. Know what's before you dig. SURVEYOR TO OBTAIN AUTOCAD FILE FROM ENGINEER AND VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. NOTE: ALL DIMENSIONS SHOWN ARE FLOWLINE TO FLOWLINE UNLESS OTHERWISE NOTED. NOTE: CONTRACTOR SHALL PROTECT ALL EXISTING SURVEY MONUMENTATION. CONTRACTOR SHALL HAVE LICENSED SURVEYOR REPLACE ANY DAMAGED OR DISTURBED MONUMENTATION AT THEIR COST. NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK # THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By: PS0000046 3/27/2018 1 SCALE: 1"=30' 0 15 30 NOTES 1.ALL CURB AND GUTTER IS CATCH CURB UNLESS NOTED OTHERWISE. 2.ALL DIMENSIONS ARE MEASURED FROM THE FLOWLINE UNLESS NOTED OTHERWISE. 3.ALL CURB AND GUTTER SHALL BE 6" VERTICAL WITH 12" GUTTER. 4.ALL IMPROVEMENTS SHALL BE PERFORMED IN A SINGLE PHASE OF CONSTRUCTION. 5.SECURITY FENCE REQUIRES APPROVAL BY SEPARATE PERMIT. 6.THE PROPOSED STORM SYSTEM AND STORMWATER DETENTION FACILITY ONSITE IS PRIVATELY OWNED AND MAINTAINED. SITE SCHEDULE EXISTING CURB AND GUTTER TO REMAIN1 2 3 4 5 6 7 8 INSTALL 6" STEEL KEYPAD BOLLARD PAINT ADA ACCESSIBLE AISLE STRIPING 4" WHITE PAINT, ANGLED 45° @ 3'-0" O.C. PAINT ADA ACCESSIBLE PARKING SPACES AND INSTALL "ACCESSIBLE PARKING ONLY" SIGN PROPOSED SAW CUT LINE INSTALL TRASH ENCLOSURE (REF ARCH. PLANS FOR DETAILS) INSTALL CURB AND GUTTER INSTALL ADA RAMP 9 INSTALL MONUMENT SIGN (50 SF PER FACE) 10 INSTALL CONCRETE WHEEL STOP OUTLINED IN BLUE WITH "NO PARKING" IN 12" WHITE LETTERING AT END OF SPACE 11 12 13 INSTALL DETECTABLE WARNING STRIP INSTALL SWING GATE WITH KNOX BOX OR CITY APPROVED EQUAL INSTALL 5' X 5' CONCRETE TRANSFORMER PAD 14 15 INSTALL 4" WHITE PARKING STRIPE 16 17 INSTALL 6' HIGH TUBE STEEL FENCE INSTALL CHOP GATE WITH KNOX BOX OR CITY APPROVED EQUAL 18 INSTALL 5' CONCRETE SIDEWALK GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN AND PERMITTING OF PROPOSED REDI ROCK RETAINING WALL. 19 PAINT 4" WHITE STRIPE SITE TABLE SIDEWALK CONCRETE 4,500 SF STANDARD DUTY ASPHALT 89,200 SF TRASH ENCLOSURE CONCRETE 200 SF 20 INSTALL WALL MOUNTED KEYPAD 21 INSTALL 6" STEEL BOLLARD 22 INSTALL DEPRESSED CURB 23 INSTALL RIPRAP 24 INSTALL STOP SIGN PARKING TABLE PROPOSED STORAGE AREA 85,883 SF STANDARD PARKING 12 SPACES ADA PARKING 2 SPACES INTERIOR LOADING PARKING 6 SPACES TOTAL PARKING 20 SPACES PROVIDED 1 SPACE/4294 SF OF STORAGE AREA REQUIRED* PARKING 85,883/6000 = 14.34 SPACES PROVIDED PARKING 85,883/4294 = 20 SPACES *REQUIRED PARKING: 1 SPACE/6000 SF OF STORAGE AREA REDEVELOPMENT AREA EXISTING PROPOSED IMPERVIOUS AREA 3,582 SF (0.08 AC) (1.6%)90,169 (2.07 AC) (41.2%) PERVIOUS AREA 215,720 SF (4.95 AC) (98.4%)128,994 SF (2.96 AC) (58.8%) TOTAL AREA 219,302 SF (5.03 AC)219,302 SF (5.03 AC) XXXX XXXXXXXXXXXXXXXXXXXX15''STM15''STMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTM STM STM STMTP G PP PP PPTP PP GM S CB CB S ST ST S S S CBCB S CBCB S S ST SS CO S N89°33'56"E 579.30' CBCHIPPENDALE AVENUE(100' R.O.W)S00 LINE RAIL ROAD(100' R.O.W)EXISTING MULTIFAMILY EXISTING STORAGE FACILITY PUBLIC STORAGE SITE AREA = 5.22 AC CANOPY = 2,149 SF FOOTPRINT = 40,897 SF 3 STORIES TOTAL BUILDING = 122,691 SF FFE = 947.00 5' GRID OFFICE T LOBBY COCOCO CO CO COCOCOCOCO OHE UT UTUT UT NO PARKING940 945939941 942 943944946 947 948940 941 942 940 941 942 943 945950 955946947 948 949 951 952 953954950 955951 952953954956950948 949951948 9 4 8946947 948948PC 45.08PC44.51 PC, ME44.04 ME 42.74 PC 43.58 PC 44.14 PC 45.63 PC, HP46.35 FL 46.68 LP 46.00 HP 46.47 FL 46.00 FL 47.00 FL 47.00 TC 47.00 TOS47.00 FL 46.06 FL 46.00 FL 46.29 HP 47.46FL46.02 FL46.72 TC46.92 FL46.92 FL47.00 FL47.00 TC47.00 TOS47.00 PC45.84 PC45.60 PC45.69FL46.21 TC46.71 FL46.18 TC46.68 PC45.90 PC45.83 PC45.78 PC45.80 LP, TOG44.91 95 0 955 94 8 94 9 9 5 1 952 953 954 RIM42.00 INV37.00 INV37.01 RIM44.83 RIM44.29 RIM46.52 RIM 47.95 FG45.97FG46.02 GBHP46.08 TOS47.00 TOS47.00 FL46.11TC46.11GBGB LP 45.00 FL 46.42 TC 46.92 3:1 MAX1.97%2.00% TOS44.30TOS43.93 TOS43.69 TOS43.93TOS43.58 BW 46.71 TW 48.71 BW 45.57 TW 47.57 BW 45.68 TW 47.68 22.7 7 % 26.0 9 % 29.0 5 % 28. 0 9 %4:14:1 4:14:1 40 45 37 38 39 41 42 43 44 46 47 45 44 46 46 4646464747 47 48 50 46 47 48 49 50 47 48 49 51 45 45 4646 46 46 46 46 46 46 46 46 47 47 46 47 46 LP, TOG45.35LP, TOG45.57 LP, TOG44.50 LP, TOG45.28 PC46.47 PC46.34 PC46.11 PC45.69 FL 45.72 FL 45.94 FL 46.08 ME 46.56 ME, TOG45.69 FL 46.08 TOG45.22 GB HP 45.66 GB FL 46.82 TC 46.92 HP 46.94 FL 46.42 TC 46.92 FL 46.42 TC 46.92FL46.92 TC 46.92 PC 43.10 DETENTION AND WQ POND DETENTION REQ'D: 61,214 FT³ INITIAL ABSTRACTION VOLUME: 18,948 FT³ 100-YR WL: 941.59 10-YR WL: 940.94 2-YR WL: 939.80 WQWL: 938.74 POND TOP: 942.00 BOND BOTTOM: 937.00 FL 46.92 TC 46.92 FL 46.42 TC 46.92 40 37 38 39 41 42 40 37 38 39 41 42 45 43 44 46 40 37 38 39 41 42 RIM42.79 FG46.74 FG46.74 FG46.74 SITE LEGEND PROPERTY BOUNDARY LINE RIGHT-OF-WAY LINE ADJACENT PROPERTY BOUNDARY LINE SETBACK LINE EXISTING EASEMENT EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED DEPRESSED CURB AND GUTTER PROPOSED BUILDING PROPOSED SWALE 1 PARKING COUNT PROPOSED CONCRETE PAVING PROPOSED HEAVY DUTY CONCRETE PAVING PROPOSED STANDARD DUTY ASPHALT PAVING PROPOSED HEAVY DUTY ASPHALT PAVING EXISTING FENCEX PROPOSED FENCE EXISTING WALL PROPOSED WALL PROPOSED GUARDRAIL PROPOSED HANDRAIL EXISTING SIGN PROPOSED SIGN PROPOSED FIRE HYDRANT PROPOSED TRASH ENCLOSURE CONCRETE PAVING EXISTING FIRE HYDRANT GRADING LEGEND 5839 EXISTING MINOR CONTOUR 5840 EXISTING MAJOR CONTOUR 36 PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR35 40.0 PROPOSED SPOT ELEVATION CATCH CURB AND GUTTERC SPILL CURB AND GUTTERS TRANSITION FROM CATCH TO SPILLT FINISHED FLOOR ELEVATIONFFE TOP OF CURBTC FLOWLINEFL FINISHED GRADEFG TOP OF GRATETOG RIM ELEVATIONRIM POINT OF CURVE RETURNPC LOW POINTLP TOP OF SIDEWALKTOS TOP OF RAMPTR EXISTING STORM SEWER12''STM PROPOSED STORM SEWER HIGH POINTHP BOTTOM OF RAMPBR TOP OF WALLTW BOTTOM OF WALLBW MATCH EXISTINGME GRADE BREAKGB GRADING PLAN C2.1 LEGAL DESCRIPTION THAT PART OF THE SOUTH HALF OF THE SOUTHWEST QUARTER LYING WEST OF STATE TRUNK HIGHWAY NO. 3, EXCEPTING THEREFROM THE RIGHT-OF-WAY OF THE CHICAGO, MILWAUKEE, ST. PAUL, AND PACIFIC RAILROAD COMPANY (NOW CALLED SOO LINE RAILROAD), ALL IN SECTION 32, TOWNSHIP 115, RANGE 19, ACCORDING TO THE UNITED STATES GOVERNMENT SURVEY THEREOF AND SITUATED IN DAKOTA COUNTY, MINNESOTA. ABSTRACT PROPERTY. BASIS OF BEARING THE DAKOTA COUNTY COORDINATE SYSTEM (NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT) AS SHOWN HEREON. BENCHMARK MNDOT 1921 S IN ROSEMOUNT, AT THE JUNCTION OF TRUNK HIGHWAY 3 AND COUNTY ROAD 42 IN ROSEMOUNT, AT TRUNK HIGHWAY 3 MILEPOINT 32.45, 62.1 FEET NORTHWEST OF TRUNK HIGHWAY 3, 83.1 FEET SOUTH OF EASTBOUND COUNTY ROAD 42 FOG LINE OF TURN LANE, 6.1 FEET SOUTHEAST OF CHAIN LINK FENCE, 5.6 FEET SOUTHEAST OF A WITNESS POST. ELEVATIONS = 958.427 FEET (NAVD 88) CAUTION - NOTICE TO CONTRACTOR 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2.WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. Know what's before you dig. SURVEYOR TO OBTAIN AUTOCAD FILE FROM ENGINEER AND VERIFY ALL HORIZONTAL CONTROL DIMENSIONING PRIOR TO CONSTRUCTION STAKING. SURVEYOR MUST VERIFY ALL BENCHMARK, BASIS OF BEARING AND DATUM INFORMATION TO ENSURE IMPROVEMENTS WILL BE AT THE SAME HORIZONTAL AND VERTICAL LOCATIONS SHOWN ON THE DESIGN CONSTRUCTION DRAWINGS. PRIOR TO CONSTRUCTION STAKING ANY DISCREPANCY MUST BE REPORTED TO OWNER AND ENGINEER PRIOR TO CONTINUATION OF ANY FURTHER STAKING OR CONSTRUCTION WORK. NOTE: ALL DIMENSIONS SHOWN ARE FLOWLINE TO FLOWLINE UNLESS OTHERWISE NOTED. Date Issue / Description# STAMP THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT CLIENT LOGO 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 Planning. Architecture. Engineering. O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved Init. NOT FOR CONSTRUCTION Date: Drawn By: Project No: Checked By:H:\Public Storage\MN, Rosemount - PS00000046 - 15854 Chippendale Ave W\CADD\3 CD\PS046_C2.1-Grading Plan.dwg - Sean Franklin - 2015-04-16PUBLIC STORAGECIVIL CONSTRUCTION DRAWINGS15854 CHIPPENDALE AVENUE WESTROSEMOUNT, MINNESOTACLIENT LOGO PS0000046 3/27/2018 1 JKG3/27/18 1ST CITY SUBMITTAL NOTE: CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL INFORMATION FOR FINAL ACCEPTANCE OF WORK FOR ANY LOCAL, STATE OR FEDERAL AGENCY, UTILITY DISTRICT OR ANY OTHER AGENCY OR DISTRICT HAVING APPROVAL AUTHORITY OVER WORK. THIS INFORMATION MAY INCLUDE, BUT IS NOT LIMITED TO, AS-BUILT PLANS, CERTIFICATIONS, INSPECTIONS AND REPORTS. NOTE: CONTRACTOR RESPONSIBLE FOR AS-BUILT DRAWINGS, TESTS, REPORTS AND/OR ANY OTHER CERTIFICATES OR INFORMATION AS REQUIRED FOR ACCEPTANCE OF WORK FROM CITY, UTILITY DISTRICTS OR ANY OTHER GOVERNING AGENCY. SOIL PREPARATION AND PAVEMENT DESIGN NOTE SOIL PREPARATION AND PAVEMENT DESIGN SHALL BE PER RECOMMENDATIONS FROM A GEOTECHNICAL REPORT PREPARED FOR THIS SITE AS FOLLOWS: GEOTECHNICAL ENGINEERING EXPLORATION AND ANALYSIS: PROPOSED PUBLIC STORAGE FACILITY GEOTECHNICAL ENGINEER: GILES ENGINEERING ASSOCIATES, INC. PROJECT NO: 1G-1709014 THE CONTRACTOR MUST FULLY REVIEW THIS REPORT PRIOR TO CONSTRUCTION. INFORMATION IN THE GEOTECHNICAL REPORT SUPERSEDES ANY CONFLICTING INFORMATION CONTAINED IN THE CONSTRUCTION PLANS AND SPECIFICATIONS. REFER TO GENERAL STRUCTURAL NOTES FOR SPECIFIC SOIL PREPARATION AT SITE STRUCTURES. SCALE: 1"=30' 0 15 30 NOTES 1.ADD 900 TO ALL SPOT ELEVATIONS. 2.CONTRACTOR SHALL FIELD VERIFY GRADES IN THE LOCATIONS INDICATED AT THE TIME OF CONSTRUCTION. CARE SHALL BE TAKEN TO MATCH EXISTING GRADES AT PROPERTY LINE TO ENSURE A SMOOTH TRANSITION BETWEEN PROPOSED ASPHALT PAVEMENT AND ADJACENT PROPERTY. 3.RIM ELEVATION FOR INLETS ARE FLOWLINE GRADES AND DO NOT TAKE INTO ACCOUNT LOCALIZED LOWERINGS PER INLET DETAILS. 1.REQUIREMENTS SHOWN ON SITE PLAN SHALL GOVERN. DRAWINGS AND SPECIFICATIONS SHOWING OTHERWISE NOTWITHSTANDING. CONTRACTOR TO POINT OUT ANY DISCREPANCIES TO THE OWNERS REPRESENTATIVE PRIOR TO BID. 2.NO WORK IS TO BEGIN UNTIL ALL PERMITS HAVE BEEN OBTAINED. 3.FINAL GRADES ARE SUBJECT TO MINOR CHANGE BY COMPANY REPRESENTATIVE. NO GRADE CHANGES IN EXCESS OF 0.05' WITHOUT COMPANY APPROVAL. ANY CHANGES ARE SUBJECT TO CITY OF ROSEMOUNT APPROVAL. 4.THIS DESIGN IS BASED ON A SOIL AND FOUNDATION INVESTIGATION. A COPY OF THIS REPORT IS AVAILABLE FOR INSPECTION BY THE CONTRACTORS. 5.ALL LANDSCAPING AREAS SHALL BE GRADED TO WITHIN 0.10' WITH COMPANY APPROVED TOP SOIL TO A MINIMUM 6" DEPTH. 6.ALL SPOT GRADES SHOWN ARE TO FLOWLINE UNLESS OTHERWISE NOTED. 7.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR MINIMIZING DEPOSITION OF ONSITE SEDIMENTS ONTO SURROUNDING PUBLIC STREETS DURING CONSTRUCTION. REFER TO EROSION CONTROL PLANS AND DETAILS FOR INFORMATION. 8.GENERAL CONTRACTOR TO PROVIDE BARRICADE PROTECTION WITH FLASHING LIGHTS AROUND ALL FOOTINGS, EXCAVATIONS AND ALL OFFSITE WORK. 9.SEE THE SITE SURVEY FOR SURVEY INFORMATION AND LEGAL DESCRIPTION. 10.THE PROPOSED STORM SYSTEM AND STORMWATER DETENTION FACILITY ONSITE IS PRIVATELY OWNED AND MAINTAINED. 11.IN LANDSCAPING AREAS ADJACENT TO PROPOSED BUILDING, MINIMUM SLOPE SHALL BE 5% FOR THE FIRST 4'. 12.GC SHALL BE RESPONSIBLE FOR DESIGN AND PERMITTING OF PROPOSED REDI ROCK RETAINING WALL. GRADING NOTES 6''W1 1/2''WPUBLIC STORAGE SITE AREA = 5.22 AC CANOPY = 2,149 SF FOOTPRINT = 40,897 SF 3 STORIES TOTAL BUILDING = 122,691 SF FFE = 947.00 5' GRID FUTURE BUILDING 17,150 SF PER FLOOR 3 STORIES 51,450 SF TOTAL FFE = 947 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WOFFICE 8''W 8''W 8''W T LOBBY G G OHE UE UE UE UE UE UEUEUEUT UTUT UT 6 NO PARKING6 XXXX UTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTXXXXXXXXXXXXXXXXXXXXUEUE UE UE UEUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTGGGGGGGGGGGGGGGG G G GUT UT U T U T 201.3 66.445.0 20.0 131.425.0 20.7 60.710.0 201.3 66.4131.412''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12'' S S 12''S S 12''S S 12''S S 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 6''W 6''W 6''W SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS15''STM15''STMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTM STM STM STMconcrete block buildingconcrete block building15854 Chippendale Avenue Rosemount, Minnesota concrete block building 13,366 sq. ft.OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12" DIP8" DIP 12" DIP 8''W 8''W 8''W 8''W 8''W 8''W8''W8''W 8''W 8''W 8" DIP 6" DIP 8" DIP 8" DIPHC WWW W W W WW W W TP G PP PP PPTP PP T GM S CB CB S ST ST S S S CBCB S CBCB S S ST SS CO S N89°33'56"E 579.30' CBCHIPPENDALE AVENUE(100' R.O.W)S00 LINE RAIL ROAD(100' R.O.W)EXISTING MULTIFAMILY EXISTING STORAGE FACILITY MH-206 5'Ø FLAT TOP MH RIM=947.94 INV IN=940.22 INV OUT=940.02 MH-204 5'Ø FLAT TOP MH RIM=946.52 INV IN=939.32 INV IN=939.32 INV OUT=939.12 IN-203 CURB INLET RIM=945.58 INV IN=938.46 INV OUT=939.59 IN-205 CURB INLET RIM=945.37 INV IN=939.65 INV OUT=939.45 IN-108 CURB INLET RIM=945.29 INV IN=939.42 INV OUT=939.22 IN-106 CURB INLET RIM=945.28 INV IN=938.48 INV OUT=938.28 IN-208 CURB INLET RIM=944.97 INV OUT=940.70 MH-104 5'Ø FLAT TOP MH RIM=944.83 INV IN=937.70 INV IN=937.70 INV OUT=937.50 IN-110 CURB INLET RIM=944.56 INV IN=940.50 INV OUT=940.31 MH-202 5'Ø FLAT TOP MH RIM=944.30 INV IN=938.46 INV IN=939.46 INV OUT=938.26 FES-102 30" FES RIM=939.79 INV IN=937.00 18'' RCP 177.64 LF @ 0.50%24'' RCP 147.14 LF @ 0.50%24'' RCP 117.00 LF @ 0.50%30'' RCP 21.41 LF @ 1.00%18'' RCP 96.60 LF @ 0.50%24'' RCP 141.06 LF @ 0.50%24'' RCP 132.24 LF @ 0.50%30'' RCP 111.96 LF @ 0.50% 18'' RCP 25.88 LF @ 0.50% 18'' RCP 25.81 LF @ 0.50% MH-304 5'Ø MH RIM=944.03 INV IN=935.65 INV OUT=935.65 OUT-302 OUTLET STRUCTURE RIM=941.59 INV OUT=936.00 IN-306 ON GRADE CURB INLET RIM=940.68 INV IN=933.50 18'' RCP 17.61 LF @ 2.00% 18'' RCP 94.53 LF @ 2.27% EX SAN MH-106 EXISTING SANITARY MANHOLE RIM=948.13 INV IN=911.25 INV OUT=911.25 SAN MH-104 REPLACE EX MH W/ DROP MH RIM=947.86 INV IN=910.62 INV IN=938.38 INV OUT=910.62 DUAL CLEANOUT DUAL CLEANOUT RIM=947.28 INV IN=939.96 INV OUT=939.96 SAN CONNECTION SEWER POINT OF ENTRY RIM=947.24 INV OUT=940.00 EX MH-102 EXISTING SANITARY MANHOLE RIM=943.90 INV IN=910.54 INV IN=933.61 12'' PVC 270.80 LF12'' PVC 175.56 LF 8'' PVC 5.00 LF8'' PVC 63.05 LF14 13 13 13 13 12 UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR PROTECT IN PLACE UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR UT CROSSING MAINTAIN 1.5' CLR 11 10 8 4 6 3 2 1 MH-103 5'Ø FLAT TOP MH RIM=942.83 INV IN=937.28 INV OUT=937.18 30'' RCP 29.24 LF @ 0.61% UTILITY CROSSING BOT=938.85 TOP=937.35 CLR 1.5± UTILITY CROSSING BOT=937.60 TOP=936.10 CLR 1.5± UTILITY CROSSING SAN BOT=939.06 WAT TOP=937.56 CLR 1.5± UTILITY CROSSING STM BOT=939.35 SAN TOP=911.65 CLR=27.70± UTILITY CROSSING STM BOT=939.20 SAN TOP=911.93 CLR=27.27± UTILITY CROSSING STM BOT=940.09 SAN TOP=912.26 CLR=27.84± UTILITY CROSSING STM BOT=937.54 SAN TOP=911.60 CLR=25.94± TELEPHONE LINE TO BE REMOVED AND REPLACED 5 6 SITE LEGEND PROPERTY BOUNDARY LINE RIGHT-OF-WAY LINE ADJACENT PROPERTY BOUNDARY LINE SETBACK LINE EXISTING EASEMENT EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED DEPRESSED CURB AND GUTTER PROPOSED BUILDING PROPOSED SWALE 1 PARKING COUNT PROPOSED CONCRETE PAVING PROPOSED HEAVY DUTY CONCRETE PAVING PROPOSED STANDARD DUTY ASPHALT PAVING PROPOSED HEAVY DUTY ASPHALT PAVING EXISTING FENCEX PROPOSED FENCE EXISTING WALL PROPOSED WALL PROPOSED GUARDRAIL PROPOSED HANDRAIL EXISTING SIGN PROPOSED SIGN PROPOSED FIRE HYDRANT PROPOSED TRASH ENCLOSURE CONCRETE PAVING UTILITY LEGEND EXISTING WATER LINE8''W PROPOSED WATER LINE8''W EXISTING STORM SEWER12''STM PROPOSED STORM SEWER EXISTING SANITARY SEWERSS PROPOSED SANITARY SEWER EXISTING GAS LINEG EXISTING UNDERGROUND ELECTRICALUE PROPOSED GAS LINEG PROPOSED UNDERGROUND ELECTRICALUE EXISTING OVERHEAD ELECTRICALOHE PROPOSED OVERHEAD ELECTRICALOHE EXISTING UNDERGROUND TELEPHONEUT PROPOSED UNDERGROUND TELEPHONEUT EXISTING FIBER OPTICFO PROPOSED FIBER OPTICFO EXISTING INLET PROPOSED INLET EXISTING MANHOLE PROPOSED MANHOLE EXISTING GATE VALVE PROPOSED GATE VALVE EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING STREET LIGHT EXISTING POWER POLE PROPOSED SITE LIGHT EXISTING WATER METER PROPOSED WATER METERW EXISTING IRRIGATION BOX EXISTING TELEPHONE BOX EXISTING TELEPHONE RISER EXISTING ELECTRICAL BOX UTILITY PLAN C4.1 CAUTION - NOTICE TO CONTRACTOR 1.ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION. 2.WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY, IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF SUCH EXISTING UTILITY, EITHER THROUGH POTHOLING OR ALTERNATIVE METHOD. REPORT INFORMATION TO THE ENGINEER PRIOR TO CONSTRUCTION. Know what's before you dig. Date Issue / Description# STAMP THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF GALLOWAY, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. COPYRIGHT CLIENT LOGO 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 Planning. Architecture. Engineering. O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved Init. NOT FOR CONSTRUCTION Date: Drawn By: Project No: Checked By:H:\Public Storage\MN, Rosemount - PS00000046 - 15854 Chippendale Ave W\CADD\3 CD\PS046_C4.1-Util Plan.dwg - Sean Franklin - 2015-04-16PUBLIC STORAGECIVIL CONSTRUCTION DRAWINGS15854 CHIPPENDALE AVENUE WESTROSEMOUNT, MINNESOTACLIENT LOGO PS0000046 3/27/2018 1 JKG3/27/18 1ST CITY SUBMITTAL OWNERSHIP AND MAINTENANCE ALL STORM SEWER LINES AND APPURTENANCES, INCLUDING THE DOWNSPOUT COLLECTION SYSTEM, PROPOSED AS A PART OF THIS PLAN WILL BE PRIVATELY OWNED AND MAINTAINED BY THE PROPERTY OWNER THEREOF OR THEIR ASSIGNS. NOTE: CONTRACTOR MUST COORDINATE WORK WITH UTILITY COMPANY AND CITY PRIOR TO BEGINNING WORK AND IS RESPONSIBLE FOR ALL MATERIALS, LABOR, REPAIRS, ETC. TO COMPLETE WORK AND RESTORE AREA TO SAME STATE PRIOR TO STARTING WORK LEGAL DESCRIPTION THAT PART OF THE SOUTH HALF OF THE SOUTHWEST QUARTER LYING WEST OF STATE TRUNK HIGHWAY NO. 3, EXCEPTING THEREFROM THE RIGHT-OF-WAY OF THE CHICAGO, MILWAUKEE, ST. PAUL, AND PACIFIC RAILROAD COMPANY (NOW CALLED SOO LINE RAILROAD), ALL IN SECTION 32, TOWNSHIP 115, RANGE 19, ACCORDING TO THE UNITED STATES GOVERNMENT SURVEY THEREOF AND SITUATED IN DAKOTA COUNTY, MINNESOTA. ABSTRACT PROPERTY. BASIS OF BEARING THE DAKOTA COUNTY COORDINATE SYSTEM (NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT) AS SHOWN HEREON. BENCHMARK MNDOT 1921 S IN ROSEMOUNT, AT THE JUNCTION OF TRUNK HIGHWAY 3 AND COUNTY ROAD 42 IN ROSEMOUNT, AT TRUNK HIGHWAY 3 MILEPOINT 32.45, 62.1 FEET NORTHWEST OF TRUNK HIGHWAY 3, 83.1 FEET SOUTH OF EASTBOUND COUNTY ROAD 42 FOG LINE OF TURN LANE, 6.1 FEET SOUTHEAST OF CHAIN LINK FENCE, 5.6 FEET SOUTHEAST OF A WITNESS POST. ELEVATIONS = 958.427 FEET (NAVD 88) SCALE: 1"=30' 0 15 30 UTILITY LINE NOTES SCHEDULE PROPOSED PRIMARY ELECTRICAL, CONTRACTOR TO COORDINATE WITH UTILITY PROVIDER PROPOSED PAD & TRANSFORMER, CONTRACTOR TO COORDINATE WITH UTILITY PROVIDER 2 3 4 BUILDING CONNECTION FOR TELEPHONE AND DATA SERVICE 5 7 9 13 EXISTING COMMUNICATIONS PEDESTAL TO BE ADJUSTED AS REQUIRED, BUILDING CONNECTION FOR ELECTRICAL SERVICE 11 12 1 10 PROPOSED TELEPHONE AND DATA SERVICE CONDUIT6 MODIFY EXISTING SANITARY MH TO EXTERIOR DROP MH. SEE DETAIL SHEET C4.2. BUILDING CONNECTION DOMESTIC WATER SERVICE WITH INTERNAL REDUCED PRESSURE BACK FLOW PREVENTER PROPOSED SECONDARY ELECTRICAL CONTRACTOR TO COORDINATE WITH UTILITY PROVIDER 8" X 6" SWIVEL TAP BUILDING CONNECTION FOR FIRE SUPPRESSION SERVICE WITH INTERNAL DOUBLE DETECTOR CHECK VALVE 8 PROPOSED FIRE DEPARTMENT CONNECTION (FDC) PROPOSED 1-INCH METER PIT. UPSIZE FROM 1-INCH TO 1.25-INCH DOMESTIC WATERLINE AFTER WATER METER. NOTES: 14 BUILDING CONNECTION FOR GAS SERVICE 1.CONTRACTOR TO REFER TO THE JURISDICTIONS STANDARD DETAILS FOR UNDERGROUND UTILITY INSTALLATION. 2.REFERENCE STORM SEWER PLAN AND PROFILE FOR STORM SEWER INFORMATION AND CROSSINGS. 3.ALL UTILITIES SHALL HAVE A MINIMUM OF EIGHTEEN INCHES (18") VERTICAL AND TEN FEET (10') HORIZONTAL SEPARATION FROM WATERMAIN. 4.ALL DISTRIBUTION WATERMAIN SHALL BE PVC C-900 PRESSURE CLASS 200 UNLESS NOTED OTHERWISE. 5.FIRE HYDRANT LATERALS AND FIRE SERVICE SHALL BE DIP CL 52 COMPLYING WITH AWWA C151. 6.SANITARY SEWER SHALL BE PVC SDR 26 COMPLYING WITH ASTM D3034. 7.ALL STORM SEWER 12" AND SMALLER SHALL BE PVC SDR26, ALL STORM PIPE 15" AND LARGER SHALL BE RCP CL IV. 8.NO BENDS ARE ALLOWED ON WATER SERVICE WITHIN 5' OF THE METER. 1.ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS FOR CITY, COUNTY, STATE AND REGULATORY AGENCIES, CURRENT EDITION. 2.THE CONTRACTOR SHALL NOTIFY THE CITY, COUNTY AND REGULATORY AGENCY 48 WORKING HOURS PRIOR TO BEGINNING CONSTRUCTION. 3.THE CONTRACTOR SHALL HAVE ONE SIGNED COPY OF THE APPROVED PLANS, ONE COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS AND A COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED AT THE JOB SITE AT ALL TIMES. 4.DISTANCES FOR UTILITY LINES ARE THE HORIZONTAL DISTANCES BETWEEN CENTER OF FITTING/CLEANOUT TO CENTER OF FITTING/CLEANOUT. THEREFORE, DISTANCES SHOWN ON THE PLANS ARE APPROXIMATE AND COULD VARY DUE TO VERTICAL ALIGNMENT AND FITTING DIMENSIONS. 5.PROVIDE A MINIMUM OF 7.5 FEET OF COVER OVER WATER LINES. 6.PROVIDE A MINIMUM OF 2.5 FEET OF COVER OVER DRY UTILITIES. 7.MAINTAIN 18 INCH MINIMUM VERTICAL CLEAR DISTANCE BETWEEN SEWER AND WATER LINES. 8.MAINTAIN 10 FOOT MINIMUM HORIZONTAL DISTANCE BETWEEN SEWER AND WATER LINES. 9.ALL WATER SERVICE LINES SHALL BE TYPE K COPPER. 10.CONTRACTOR TO VERIFY THE HORIZONTAL AND VERTICAL LOCATION OF ALL UTILITIES, WHETHER SHOWN OR NOT, PRIOR TO CONSTRUCTION. REPORT ANY CONFLICTS TO THE ENGINEER. 11.REFER TO BUILDING PLANS FOR EXACT LOCATION OF ALL UTILITY STUBS. 12.CONTRACTOR IS RESPONSIBLE FOR ALL SURFACE RESTORATION (I.E. LANDSCAPE, ASPHALT, CONCRETE, ETC.). 13.ALL TRENCH EXCAVATION SHALL BE PROPERLY SLOPED, SHORED, OR OTHERWISE SUPPORTED IN A MANNER REQUIRED BY OSHA OR AS REQUIRED BY STATE OR LOCAL LAWS. 14.WATERLINE AND METER SHALL BE THE SAME SIZE FROM TAP. METERS SHALL BE AT LEAST 2-FEET FROM CONCRETE. METERS NOT IN R.O.W. SHOULD HAVE A DEDICATED EASEMENT PER C.O.A. SPEC 5.04. 15.MAINTAIN 2-FOOT MINIMUM VERTICAL CLEARANCE DISTANCE WHEN WATER CROSSES OVER SANITARY SEWER. 16.DUCTILE IRON AND STEEL PIPE SHALL NOT BE USED ON THIS SITE DUE TO THE CORROSIVE NATURE OF THE SOILS. ALL PIPE SHALL BE PVC (WITH THE EXCEPTION OF SERVICE LINES 2” AND SMALLER) PER SECTION 14 OF THE STANDARDS AND SPECIFICATIONS REGARDING WATER, SANITARY SEWER AND STORM DRAINAGE INFRASTRUCTURE, LATEST REVISION. 17.ALL DUCTILE IRON FITTINGS, APPURTENANCES AND TYPE K-COPPER SERVICE LINES SHALL BE DOUBLE BONDED AND DOUBLE POLY-WRAPPED PER SECTION 12 AND SECTION 20 OF THE STANDARDS AND SPECIFICATIONS REGARDING WATER, SANITARY SEWER AND STORM DRAINAGE INFRASTRUCTURE, LATEST REVISION. OFFICELOBBYUTUTUTPPPPN89°33'56"E 579.30'PPPPN89°33'56"E 579.30'CHIPPENDALE AVENUE WEST158TH STREET7.0 8.2 8.2 8.2 8.5 8.5 8.3 9.5 6.5 8.2 8.7 8.5 8.8 9.4 9.2 8.7 8.6 8.9 9.5 10.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.4 0.5 0.5 0.5 0.5 0.5 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.3 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.8 1.3 1.5 1.7 1.5 1.5 1.7 1.4 1.1 0.6 0.3 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.4 0.5 0.8 0.7 0.3 0.3 0.4 0.4 0.4 0.4 0.5 0.6 1.1 2.5 4.3 4.7 4.7 5.1 5.2 3.9 4.6 3.7 1.8 0.8 0.6 0.5 0.5 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.4 0.0 0.6 2.2 2.2 1.6 1.9 2.1 2.1 2.1 2.1 2.3 2.3 3.0 6.1 10.9 3.8 9.9 9.2 10.5 7.5 2.5 9.3 4.4 2.5 2.3 2.3 2.1 1.8 1.6 1.2 0.7 0.4 0.3 0.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 0.8 0.3 0.0 3.9 3.7 2.9 3.3 3.7 3.6 3.6 3.7 3.9 3.7 4.2 6.4 9.1 8.2 5.2 3.9 3.7 3.9 3.5 3.2 2.6 2.0 1.3 0.8 0.5 0.2 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.7 1.8 3.1 7.1 6.8 5.9 6.2 6.3 6.4 7.1 6.7 6.6 6.5 7.1 7.0 6.2 6.5 6.9 7.0 6.4 6.5 6.6 6.5 4.9 3.8 2.7 1.8 0.8 0.4 0.4 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.9 2.6 4.5 7.5 11.3 6.8 9.4 9.4 8.8 9.3 10.7 10.0 9.0 9.2 10.3 10.0 9.5 9.8 9.7 10.2 9.0 8.9 9.7 9.6 7.4 7.2 7.6 5.2 1.4 0.3 0.5 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.1 3.4 5.9 10.3 14.8 0.1 0.8 0.6 0.4 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.8 3.3 5.7 10.4 14.4 0.2 1.5 1.2 0.7 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 3.4 5.9 10.7 15.1 3.5 2.9 2.1 1.2 0.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 3.3 5.8 10.0 13.3 6.2 4.9 3.2 1.8 0.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.9 3.2 5.3 8.3 10.8 9.0 7.1 4.2 2.2 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.8 2.8 4.7 7.6 10.0 10.0 8.0 4.8 2.6 0.9 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.7 2.4 4.3 7.5 10.4 9.4 7.6 5.1 2.9 1.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 2.0 3.6 6.7 9.4 9.6 7.9 5.3 3.1 1.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 1.7 2.9 4.9 6.5 10.5 8.6 5.4 2.9 1.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.7 1.1 2.0 3.1 4.2 10.6 8.6 5.4 2.9 1.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 1.2 2.2 3.5 6.6 8.1 11.2 11.3 9.4 7.7 5.2 3.0 1.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.8 1.5 2.5 5.1 6.4 9.5 11.1 9.2 7.6 5.1 3.0 1.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.5 0.9 1.6 3.7 4.7 7.9 10.9 9.7 8.1 4.9 2.7 1.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.5 1.1 2.7 4.0 6.4 9.2 9.1 7.5 4.3 2.3 0.9 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.5 1.6 2.4 3.8 5.4 5.5 5.3 4.0 2.1 1.2 7.0 5.5 3.5 2.0 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.4 1.1 1.8 2.8 4.0 2.5 5.1 8.1 9.9 9.1 9.0 10.0 10.9 9.6 9.2 10.0 10.9 9.5 8.9 9.5 9.7 7.5 4.8 3.1 3.0 4.4 6.7 8.5 7.3 4.6 2.2 1.3 4.3 3.5 2.5 1.4 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.7 1.2 1.8 2.6 2.0 3.7 5.2 6.5 6.3 6.6 6.7 7.3 6.7 6.8 6.8 7.2 6.5 6.4 6.2 6.2 4.9 3.6 2.6 2.5 3.3 4.2 5.0 4.5 3.2 1.8 1.1 2.3 1.9 1.4 0.8 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.6 1.0 1.4 1.3 2.1 2.7 3.2 3.5 3.9 3.7 3.7 3.8 4.0 3.8 3.7 3.6 3.8 3.4 3.0 2.6 2.2 1.6 1.5 2.0 2.3 2.4 2.3 1.9 1.1 0.7 1.4 1.0 0.7 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.6 0.9 0.8 1.3 1.6 1.8 2.1 2.3 2.2 2.2 2.2 2.3 2.2 2.1 2.1 2.2 1.9 1.7 1.5 1.3 1.0 0.9 1.1 1.2 1.3 1.2 1.0 0.7 0.4 0.8 0.6 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.2 0.3 0.3 0.3 0.2 0.1 0.1 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Date Issue / Description# STAMP COPYRIGHT CLIENT LOGO 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 Planning. Architecture. Engineering. O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved Init. NOT FOR CONSTRUCTION Date: Drawn By: Project No: Checked By:H:\Public Storage\MN, Rosemount - PS00000046 - 15854 Chippendale Ave W\CADD\3 CD\PS046_C4.4-Lite.dwg - Sean Franklin - 2015-04-16PUBLIC STORAGECIVIL CONSTRUCTION DRAWINGS15854 CHIPPENDALE AVENUE WESTROSEMOUNT, MINNESOTACLIENT LOGO PS0000046 3/27/2018 1 JKG3/27/18 1ST CITY SUBMITTAL SCALE: 1"=40' 0 20 40 JMG ARK PHOTOMETRIC PLAN C4.4 THE PHOTOMETRIC PLAN REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS UTILIZING CURRENT INDUSTRY STANDARD LAMP RATINGS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS. LABORATORY TESTS ARE MADE UNDER OPTIMUM CONDITION, WITH LAMP OUTPUT AT RATED VALUE, AND IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY APPROVED METHODS. THE STUDY IS BASED ON REQUESTED ILLUMINATION LEVELS, LUMINAIRE LOCATIONS, OR ADDITIONAL CRITERIA BY THE AUTHORITIES HAVING JURISDICTION. THE CALCULATED PHOTOMETRIC LEVELS MAY OR MAY NOT MEET CERTAIN STANDARDS OR RECOMMENDED PRACTICES OF IESNA. ACTUAL ILLUMINANCE LEVELS MAY DIFFER DUE TO VARIABLE FIELD CONDITIONS SUCH AS (BUT NOT LIMITED TO): VARIANCE IN LAMP LUMEN OUTPUT; LAMP TILT FACTOR; BALLAST WATTAGE OUTPUT; LINE VOLTAGE AT BALLAST; REFLECTOR SPECULARITY; LAMP LUMEN DEPRECIATION; AND LUMINAIRE DIRT DEPRECIATION.  ALL AREA SITE LIGHT FIXTURES AND POLES TO BE MOUNTED ON 2'-0" CONCRETE BASE PER PUBLIC STORAGE STANDARDS. SEE SITE DETAIL SHEETS. ALL ANCHOR BOLTS TO BE ORIENTED IN THE SAME DIRECTION (SQUARE) AT INSTALLATION PER MANUFACTURER'S SPECIFICATIONS. GENERAL LIGHTING NOTES: LUMINAIRE SCHEDULE SYMBOL QTY LABEL ARRANGEMENT LLF MODEL WATTS 18 SA SINGLE 1.0 HE-ENV-90W-LED-LFL-50K-PS-UNV-ST-KHEH 90 MOUNTING 23'-6" WALL DESCRIPTION ENVIROLUX LIGHTING, SMALL STEALTH WALL PACK, FULLY SHIELDED, TYPE 3 DISTRIBUTION, LUMENS 14178INTERNALLY PAINTED DARK BRONZE, 50K, WALL MOUNTED WITH KHEH BRACKET 2 C SINGLE 1.0 CITCL232X1LN18.5W40 379'-8" SURFACE 2393TEXAS FLUORESCENTS, 4' LINEAR LED STRIP WITH (2) 18.5 WATT 40K TUBES 3 CE SINGLE 1.0 379'-8" SURFACE 2393 G.C. TO VERIFY VOLTAGE BEFORE ORDERING ANY EQUIPMENT 4 G SINGLE 1.0 EES-5500K-42W-LED-LWPCO-PS-UNV 4215'-6" WALL 6544ENVIROLUX LIGHTING, LARGE LED WALL PACK PRO SERIES, FULL CUTOFF SHIELDED, TYPE 3 DISTRIBUTION, INTERNALLY PAINTED CITCL232X1LN18.5W40 EMK12 TEXAS FLUORESCENTS, 4' LINEAR LED STRIP WITH (2) 18.5 WATT 40K TUBES WITH EMERGENCY BACKUP PUBLIC STORAGE UTILIZES US ENERGY SERVICE, INC. FOR LUMINAIRE SUPPLY. CONTACT BRAD BOYETT (BBOYETT@EARTHLINK.NET) AT (512) 423-3094. ENLARGED PHOTOMETRIC SITE PLAN1SCALE: 1"=40'-0" W5 W5 W5 W5 W5 W5 W5 W5 W5 CE CE CE C C W5 W5 G G G G W5 W5 W5 W5 W5 W5 W5 ALL NONESSENTIAL LIGHTING WILL BE REQUIRED TO BE TURNED OFF AFTER BUSINESS HOURS, LEAVING ONLY THE NECESSARY LIGHTING FOR SITE SECURITY. CITY LIGHTING NOTE: X XXXXXXXXXXXXUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTXXXXXXXXXXXXUEUE UE UE UEUTUTUTUTUTUTUTUTUTUTUTUTUTUTUTGGGGGGGGGGGGGGGG G G GUT UT UTU T 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 12''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 8''SS 6''W SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS15''STM15''STMSTMSTMSTMSTMSTMSTMSTMSTMSTMSTMS TM S TM S TM STMOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12"DIP8" DIP 12" DIP 8''W 8''W 8''W 8''W 8''W 8''W8" DIP 6"DIP8" DIP HC TP G TP GM S S ST S S S S S ST SS CO S N89°33'56"E 579.30'CHIPPENDALEAVENUESSSS6''W11/2''WFUTURE BUILDING 17,150 SF PER FLOOR 3 STORIES 51,450 SF TOTAL FFE = 947 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W8''WOFFICE 8''W 8''W 8''W LOBBY COCO CO COCO G G O H E UE UE UE UE UE UEUEUEUT UTUT UT NOPARKING9-HESE 1-PISL 1-POFA 1-PHSE 4-CAKF 12-HAVI 1-QUMA 3-POFA 3-FOAR 2-CASP 3-POFA 6-FOAR 1-QUMA 6-POFA 6-FOAR 4-PHSE 26-HESE 6-POFA 1-GLSH SOD, TYP. SEEPLANTING NOTES &LEGEND. EXTENDPROPOSED SOD TOLIMITS OFCONSTRUCTION EXISTING SOD TOREMAIN SOD, TYP. SEEPLANTING NOTES &LEGEND. EXTENDPROPOSED SOD TOLIMITS OFCONSTRUCTION SEED, TYP. SEESEED NOTES &LEGEND. EXTENDSEED TO LIMITS OFCONSTRUCTIONROCK MULCH, TYP.SEE PLANTINGNOTES & LEGEND ROCK MULCH, TYP.SEE PLANTINGNOTES & LEGENDROCK MULCH, TYP.SEE PLANTINGNOTES & LEGEND ROCK MULCH, TYP.SEE PLANTINGNOTES & LEGEND (4) EXISTING TREESTO REMAIN, TYP.SEE TREEPROTECTIONNOTES WEST 158TH STREET 1-ULAM REDEVELOPMENT AREA REDEVELOPMENT AREA REDEVELOPMENT AREA REDEVELOPMENT AREA (20) EXISTINGTREES TO REMAIN,TYP. SEE TREEPROTECTIONNOTES PROPOSEDMONUMENT SIGN SEED, TYP. SEESEED NOTES &LEGEND. EXTENDSEED TO LIMITS OFCONSTRUCTION 12-POFA 8-PHSE 55-HESE 42-FOAR 9-HAVI 17-FOAR ROCK MULCHINSIDE FENCE LINE,TYP. SEE PLANTINGNOTES & LEGEND STEEL EDGING,TYP. SEE PLANTINGNOTES & LEGEND # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By:H:\PublicStorage\MN,Rosemount-PS00000046-15854ChippendaleAveW\CADD\3CD\PS046_L1.1-LandscapePlan.dwg-SarahAdamson-2015-04-16PS0000046 3/27/2018 1 EVERGREEN SHRUBS ORNAMENTAL GRASSES FEATHER REED GRASS SEED, MULCH AND MISCELLANEOUS SODFESCUE BLEND SOD 2" - 4" DIA. MULTI - COLOR ROCK MULCH W/ SHREDDED BARK MULCH RING, SEE MULCH NOTES OVERSTORY DECIDUOUS TREES PLANTING LEGEND DECIDUOUS SHRUBS FORSYTHIA 'NORTHERN GOLD' CALAMAGROSTIS ACUTIFLORA 'KARL FOERSTER' FOAR CAKF NORTHERN GOLD FORSYTHIA TURF MULCH ROCK MULCH COMMON NAMEBOTANIC NAMESYMBOLLEGEND ABBREV.QUANTITY MATURE SIZE WATER USE 74 8' X 7' LOW / MOD 4 4.5' X 2.0'LOW ± 33,890 ---MODERATE 21,900 SF ------ PHYSOCARPUS OPULIFOLIUS 'SEWARD'PHSE SUMMER WINE NINEBARK 13 4' X 4' MODERATE PLANTING SIZE #5 CONTAINER 18"-24" 2 70' X 50'QUERCUS MACROCARPA BUR OAKQUMA 2.0" CAL. B&B LOW BLUE AVENA GRASSHELICTOTRICHON SEMPERVIRENSHESE 90 2' X 2'LOW #5 CONTAINER 18"-24" #1 CONTAINER #1 CONTAINER 1 40' X 40'GLEDITSIA TRIACANTHOS INERMIS 'SKYLINE'SKYLINE HONEYLOCUSTGLSH 2.0" CAL. B&B LOW 1 70' X 50'ULMUS AMERICANA 'PRINCETON'PRINCETON ELMULAM 2.0" CAL. B&B MODERATE 2 50' X 30'CATALPA SPECIOSA NORTHERN CATALPACASP 2.0" CAL. B&B LOW HAMAMELIS VIRGINIANA'HAVI COMMON WITCHHAZEL 21 18' X 20'LOW#5 CONTAINER 18"-24" POTENTILLA FRUTICOSA 'FARGO'POFA DAKOTA SUNSPOT POTENTILLA 31 3' X 3' LOW / MOD#5 CONTAINER 18"-24" PINUS MUGO 'SLOWMOUND'PISL SLOWMOUND MUGO PINE 1 3' X 4'LOW#5 CONTAINER 18"-24" SCALE: 1"=30' 0 15 30 CAUTIONUTILITIES EXIST WITHIN CONSTRUCTION LIMITS. CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING THEIR LOCATION PRIOR TO CONSTRUCTION. NATIVE SEED; SEE NOTESDRYLAND SEED MIXSEED ±5,800 SF ---MODERATE DTT SRA LANDSCAPE PLAN L1.1 REDEVELOPMENT AREA EXISTING PROPOSED IMPERVIOUS AREA 3,582 SF (0.08 AC) (1.6%) 90,169 (2.07 AC) (41.2%) PERVIOUS AREA 215,720 SF (4.95 AC) (98.4%) 128,994 SF (2.96 AC) (58.8%) TOTAL AREA 219,302 SF (5.03 AC) 219,302 SF (5.03 AC) 1. THE LANDSCAPE CONTRACTOR IS REQUIRED TO CONTACT THE COUNTY PUBLIC WORKS DEPARTMENT, AND ANY OTHER PUBLIC OR PRIVATE AGENCY NECESSARY FOR UTILITY LOCATION PRIOR TO ANY CONSTRUCTION. 2. THIS DRAWING IS A PART OF A COMPLETE SET OF BID DOCUMENTS, SPECIFICATIONS, ADDITIONAL DRAWINGS, AND EXHIBITS. UNDER NO CIRCUMSTANCES SHOULD THESE PLANS BE USED FOR CONSTRUCTION PURPOSES WITHOUT EXAMINING ACTUAL LOCATIONS OF UTILITIES ON SITE, AND REVIEWING ALL RELATED DOCUMENTS. 3. THE LOCATION OF THE ALL UNDERGROUND UTILITIES ARE LOCATED ON THE ENGINEERING DRAWINGS FOR THIS PROJECT. THE MOST CURRENT REVISION IS HERE IN MADE PART OF THIS DOCUMENT. UNDERGROUND UTILITIES EXIST THROUGHOUT THIS SITE AND MUST BE LOCATED PRIOR TO ANY CONSTRUCTION ACTIVITY. WHERE UNDERGROUND UTILITIES EXIST, FIELD ADJUSTMENT MAY BE NECESSARY AND MUST BE APPROVED BY A REPRESENTATIVE OF THE OWNER. NEITHER THE OWNER NOR THE LANDSCAPE ARCHITECT ASSUMES ANY RESPONSIBILITY WHATSOEVER, IN RESPECT TO THE CONTRACTORS ACCURACY IN LOCATING THE INDICATED PLANT MATERIAL, AND UNDER NO CIRCUMSTANCES SHOULD THESE PLANS BE USED WITHOUT REFERENCING THE ABOVE MENTIONED DOCUMENTS. UTILITY NOTES AREAS OF REQUIRED LANDSCAPING MINIMUM 25% OF DEVELOPMENT AREA MUST BE PERVIOUS FORMULA 219,302 X 0.25 TOTAL QUANTITY REQUIRED 54,825 SF TOTAL QUANTITY PROVIDED 128,994 SF AREA TOTAL DEVELOPMENT AREA: 54,825 SF 1 SHRUB PER 10 LF PERIMETER FENCE 86 SHRUBS81 SHRUBS808 LINEAL FEET 808 / 10 1.25 TREES PER 3000 SF OF REQUIRED LANDSCAPE AREA (54,825 / 3,000) X 1.25 22.8 TREES54,825 SF 30 TREES LANDSCAPE CALCULATIONS # 6162 S. Willow Drive, Suite 320 Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com C 2015. Galloway & Company, Inc. All Rights Reserved Date: Drawn By: Project No: Checked By:H:\PublicStorage\MN,Rosemount-PS00000046-15854ChippendaleAveW\CADD\3CD\PS046_L1.1-LandscapePlan.dwg-SarahAdamson-2015-04-16PS0000046 3/27/2018 1 DTT SRA LANDSCAPE NOTES & DETAILS L1.2 IRRIGATION CONCEPT 1. AN AUTOMATIC IRRIGATION SYSTEM SHALL BE INSTALLED AND OPERATIONAL BY THE TIME OF FINAL INSPECTION. THE ENTIRE IRRIGATION SYSTEM SHALL BE INSTALLED BY A QUALIFIED IRRIGATION CONTRACTOR. 2. THE IRRIGATION SYSTEM WILL HAVE APPROPRIATE BACKFLOW PREVENTION DEVICES INSTALLED TO PREVENT CONTAMINATION OF THE WATER SOURCE IF APPLICABLE. 3. ALL NON-TURF/SEED PLANTED AREAS WILL BE DRIP IRRIGATED. TURF SOD/SEED SHALL RECEIVE POP-UP SPRAY IRRIGATION FOR HEAD TO HEAD COVERAGE. 4. ALL PLANTS SHARING SIMILAR HYDROZONE CHARACTERISTICS SHALL BE PLACED ON A VALVE DEDICATED TO PROVIDE THE NECESSARY WATER REQUIREMENTS SPECIFIC TO THAT HYDROZONE. 5. THE IRRIGATION SYSTEM SHALL BE DESIGNED AND INSTALLED, TO THE MAXIMUM EXTENT POSSIBLE, TO CONSERVE WATER BY USING THE FOLLOWING DEVICES AND SYSTEMS: MATCHED PRECIPITATION RATE TECHNOLOGY ON ROTOR AND SPRAY HEADS (WHEREVER POSSIBLE), RAIN SENSORS, AND SMART MULTI-PROGRAM COMPUTERIZED IRRIGATION CONTROLLERS FEATURING SENSORY INPUT CAPABILITIES. 1. THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL TREES, SHRUBS, PERENNIALS, SOD, SEEDED AREAS, AND IRRIGATION SYSTEMS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE OWNER'S ACCEPTANCE. THE CONTRACTOR SHALL REPLACE, AT HIS OWN EXPENSE, ANY PLANTS WHICH DIE IN THAT TIME, OR REPAIR ANY PORTIONS OF THE IRRIGATION SYSTEM WHICH OPERATE IMPROPERLY. 2. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE LANDSCAPE IN A NEAT, CLEAN, AND HEALTHY CONDITION FOR A PERIOD OF 90 DAYS. THIS SHALL INCLUDE PROPER PRUNING, MOWING AND AERATION OF LAWNS, WEEDING, REPLACEMENT OF MULCH, REMOVAL OF LITTER, AND THE APPROPRIATE WATERING OF ALL PLANTINGS. IRRIGATION SHALL BE MAINTAINED IN PROPER WORKING ORDER, WITH SCHEDULING ADJUSTMENTS BY SEASON AND TO MAXIMIZE WATER CONSERVATION. IF SITE OPENS DURING WINTER, TO AVOID FREEZE DAMAGE ON PLANTINGS, THE 90 DAYS SHOULD BEGIN AFTER ACCEPTANCE OF THE WORK. 3. DURING THE LANDSCAPE MAINTENANCE PERIOD, THE LANDSCAPE CONTRACTOR SHALL MAINTAIN POSITIVE DRAINAGE AWAY FROM STRUCTURES IN ALL LANDSCAPE AREAS AT THE MINIMUM SLOPE SPECIFIED IN THE GEOTECHNICAL REPORT. LANDSCAPE AREAS WHICH SETTLE AND CREATE THE POTENTIAL FOR PONDING SHALL BE REPAIRED TO ELIMINATE PONDING POTENTIAL AND BLEND IN WITH THE SURROUNDING GRADES. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GEOTECHNICAL REPORT, THE GRADING PLANS, THESE NOTES, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND OWNER. LANDSCAPE GUARANTEE AND MAINTENANCE PLANTING NOTES GENERAL 1.ALL WORK SHALL CONFORM TO ALL APPLICABLE STATE AND LOCAL CODES, STANDARDS, AND SPECIFICATIONS. 2.LANDSCAPE DESIGN IS DIAGRAMMATIC IN NATURE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN TAKEOFFS AND QUANTITY CALCULATIONS. IN THE EVENT OF A DISCREPANCY BETWEEN THE PLAN AND THE LANDSCAPE LEGEND, THE PLANT QUANTITY AS SHOWN ON THE PLAN SHALL TAKE PRECEDENCE AND NOTIFY THE LANDSCAPE ARCHITECT OF THESE DISCREPANCIES. MINOR ADJUSTMENTS TO THE LANDSCAPE MATERIAL AND LOCATIONS MAY BE PROPOSED FOR CITY CONSIDERATION AT THE CONSTRUCTION DOCUMENT STAGE TO RESPOND TO MARKET AND FIELD CONDITIONS. HOWEVER, THERE SHALL BE NO REDUCTION IN THE NUMBER AND SIZE OF MATERIALS. 3.CONTRACTOR SHALL MAKE HIMSELF AWARE OF THE LOCATIONS OF EXISTING AND PROPOSED UTILITIES, AND SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE UTILITIES AND/OR ANY INJURY TO ANY PERSON. THIS DRAWING IS PART OF A COMPLETE SET OF CONTRACT DOCUMENTS. UNDER NO CIRCUMSTANCES SHOULD THIS PLAN BE USED FOR CONSTRUCTION PURPOSES WITHOUT EXAMINING ACTUAL LOCATIONS OF UTILITIES ON SITE AND REVIEW ALL RELATED PLANS AND DOCUMENTS. 4.ALL UTILITY EASEMENTS SHALL REMAIN UNOBSTRUCTED AND FULLY ACCESSIBLE ALONG THEIR ENTIRE LENGTH FOR MAINTENANCE EQUIPMENT. 5.THE CONTRACTOR SHALL TAKE EXTREME CARE NOT TO DAMAGE ANY EXISTING PLANTS INDICATED AS "TO REMAIN". ANY SUCH PLANTS DAMAGED BY THE CONTRACTOR SHALL BE REPLACED WITH THE SAME SPECIES, SIZE, AND QUANTITY AT THE CONTRACTOR'S OWN EXPENSE, AND AS ACCEPTABLE TO THE OWNER. REFER TO THE TREE PROTECTION NOTES ON THE PLANS (AS APPLICABLE). 6.LANDSCAPE CONTRACTOR SHALL EXAMINE THE SITE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND NOTIFY THE GENERAL CONTRACTOR IN WRITING OF UNSATISFACTORY CONDITIONS. IF SITE CONDITIONS OR PLANT AVAILABILITY REQUIRE CHANGES TO THE PLAN, THEN AN APPROVAL WILL BE OBTAINED FROM THE CITY. DO NOT PROCEED UNTIL CONDITIONS HAVE BEEN CORRECTED. 7.ALL CONSTRUCTION DEBRIS AND MATERIAL SHALL BE REMOVED AND CLEANED OUT PRIOR TO INSTALLATION OF TOPSOIL, TREES, SHRUBS, AND TURF. 8.FOR ALL INFORMATION ON SURFACE MATERIAL OF WALKS, DRIVES, AND PARKING LOTS, SEE THE SITE PLAN. SEE PHOTOMETRIC PLAN FOR FREE STANDING LIGHTING INFORMATION. 9.THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT ONE WEEK PRIOR TO BEGINNING CONSTRUCTION. 10. WINTER WATERING SHALL BE AT THE EXPENSE OF THE CONTRACTOR UNTIL SUCH TIME AS FINAL ACCEPTANCE IS RECEIVED. 11. ALL LANDSCAPE CONSTRUCTION PRACTICES, WORKMANSHIP, AND ETHICS SHALL, BE IN ACCORDANCE WITH INDUSTRY STANDARDS SET FORTH IN THE INSPECTION & CONTRACT ADMINISTRATION MANUAL FOR MnDOT LANDSCAPE PROJECTS. 12. LANDSCAPE AND IRRIGATION WORK SHALL BE COMPLETED PRIOR TO THE ISSUANCE OF THE FINAL CERTIFICATE OF OCCUPANCY. FINISH GRADING AND SOIL PREPARATION 13. CONTRACTOR SHALL CONSTRUCT AND MAINTAIN FINISH GRADES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREAS SHALL HAVE POSITIVE DRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPE SPECIFIED IN THE REPORT, AND AREAS OF POTENTIAL PONDING SHALL BE REGRADED TO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDING POTENTIAL. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GEOTECHNICAL REPORT, THE GRADING PLANS, THESE NOTES, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT AND OWNER. 14. AFTER FINISH GRADES HAVE BEEN ESTABLISHED, IT IS RECOMMENDED THAT THE CONTRACTOR SHALL HAVE SOIL SAMPLES TESTED BY AN ESTABLISHED SOIL TESTING LABORATORY FOR THE FOLLOWING: GENERAL SOIL FERTILITY, PH, ORGANIC MATTER CONTENT, SALT (CEC), LIME, SODIUM ADSORPTION RATIO (SAR) AND BORON CONTENT. EACH SAMPLE SUBMITTED SHALL CONTAIN NO LESS THAN ONE QUART OF SOIL. CONTRACTOR SHALL ALSO SUBMIT THE PROJECT'S PLANT LIST TO THE LABORATORY ALONG WITH THE SOIL SAMPLES. THE SOIL REPORT PRODUCED BY THE LABORATORY SHALL CONTAIN RECOMMENDATIONS FOR THE FOLLOWING (AS APPROPRIATE): GENERAL SOIL PREPARATION AND BACKFILL MIXES, PRE-PLANT FERTILIZER APPLICATIONS, AND ANY OTHER SOIL RELATED ISSUES. THE REPORT SHALL ALSO PROVIDE A FERTILIZER PROGRAM FOR THE ESTABLISHMENT PERIOD AND FOR LONG-TERM MAINTENANCE. 15. THE CONTRACTOR SHALL RECOMMEND INSTALLATION OF SOIL AMENDMENTS AND FERTILIZERS PER THE SOILS REPORT FOR THE THE OWNER/OWNER'S REPRESENTATIVE CONSIDERATION. 16. AT A MINIMUM, ALL TOPSOIL SHALL BE AMENDED WITH COMPOST GRADE 2 FROM AN MnDOT CERTIFIED SUPPLIER, OR APPROVED EQUAL AND 10 LBS. OF 12-12-12 FERTILIZER PER CU. YD., ROTOTILLED TO A DEPTH OF 8". NO MANURE OR ANIMAL-BASED PRODUCTS SHALL BE USED FOR ORGANIC AMENDMENTS. PLANTING 17. ALL DECIDUOUS TREES SHALL HAVE FULL, WELL-SHAPED HEADS/ALL EVERGREENS SHALL BE UNSHEARED AND FULL TO THE GROUND; UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRAL LEADERS WILL NOT BE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGS AFTER PLANTING. 18. ALL PLANTS WITHIN A SPECIES SHALL HAVE SIMILAR SIZE, AND SHALL BE OF A FORM TYPICAL FOR THE SPECIES. ANY PLANT DEEMED UNACCEPTABLE BY THE LANDSCAPE ARCHITECT SHALL BE IMMEDIATELY REMOVED FROM THE SITE AND SHALL BE REPLACED WITH AN ACCEPTABLE PLANT OF LIKE TYPE AND SIZE AT THE CONTRACTOR'S OWN EXPENSE. ANY PLANTS APPEARING TO BE UNHEALTHY, EVEN IF DETERMINED TO STILL BE ALIVE, SHALL NOT BE ACCEPTED. THE LANDSCAPE ARCHITECT SHALL BE THE SOLE JUDGE AS TO THE ACCEPTABILITY OF PLANT MATERIAL. 19. ALL TREES SHALL BE GUYED AND WOOD STAKED AS PER DETAILS. NO 'T-STAKES' SHALL BE USED FOR TREES. 20. ALL PLANT MATERIALS SHALL BE TRUE TO TYPE, SIZE, SPECIES, QUALITY, AND FREE OF INJURY, BROKEN ROOT BALLS, PESTS, AND DISEASES, AS WELL AS CONFORM TO THE MINIMUM REQUIREMENTS DESCRIBED IN THE "AMERICAN STANDARD FOR NURSERY STOCK". 21. ALL TREE AND SHRUB BED LOCATIONS ARE TO BE STAKED OUT ON SITE FOR APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 22. ALL TREES PLANTED ADJACENT TO PUBLIC AND/OR PEDESTRIAN WALKWAYS SHALL BE PRUNED CLEAR OF ALL BRANCHES BETWEEN GROUND AND A HEIGHT OF EIGHT (8) FEET FOR THAT PORTION OF THE PLAN LOCATED OVER THE SIDEWALK AND/OR ROAD. 23. ALL PLANT MATERIAL SHALL NOT BE PLANTED PRIOR TO INSTALLATION OF TOPSOIL. 24. ALL PLANT BEDS SHALL BE CONTAINED WITH STEEL EDGER. STEEL EDGER IS NOT REQUIRED ALONG CURBS, WALKS OR BUILDING FOUNDATIONS. ALL EDGING SHALL OVERLAP AT JOINTS A MINIMUM OF 6-INCHES, AND SHALL BE FASTENED WITH A MINIMUM OF 4 PINS PER EACH 10 FOOT SECTION. THE TOP OF ALL EDGING MATERIAL SHALL BE A ROLLED TOP AND 1/2 INCH ABOVE THE FINISHED GRADE OF ADJACENT LAWN OR MULCH AREAS. COLOR: BLACK. 25. THE DEVELOPER, HIS SUCCESSOR, OR ASSIGNEE SHALL BE RESPONSIBLE FOR ESTABLISHING AND CONTINUING A REGULAR PROGRAM OF MAINTENANCE FOR ALL LANDSCAPED AREAS. SEE LANDSCAPE GUARANTEE AND MAINTENANCE NOTE. 26. A 3-FOOT CLEAR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF ALL FIRE HYDRANTS. 27. LANDSCAPE CONTRACTOR TO SUBMIT SAMPLES OF MISCELLANEOUS LANDSCAPING MATERIALS TO THE LANDSCAPE ARCHITECTS AND OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TO INSTALLATION, IE.; MULCH, EDGER, LANDSCAPE FABRIC, ETC. MULCHING 28. AFTER ALL PLANTING IS COMPLETE, THE CONTRACTOR SHALL INSTALL A MINIMUM 4" THICK LAYER OF MULCH AS SPECIFIED IN THE PLANTING LEGEND. INSTALL A 4" THICK RING OF DOUBLE SHREDDED HARDWOOD MULCH AROUND ALL PLANT MATERIAL IN ROCK MULCH BEDS WHERE LANDSCAPING IS SHOWN ON THE PLANS. WOOD MULCH RING SIZE SHALL BE A MINIMUM OF 3' (THREE FEET) FOR ALL TREES AND SHRUBS, AND 2' (TWO FEET) FOR ALL PERENNIALS, VINES AND GRASSES. 29. ALL MULCH SHALL BE HARVESTED IN A SUSTAINABLE MANNER FROM A LOCAL SOURCE. 30. INSTALL DEWITT PRO-5 WEED BARRIER FABRIC UNDER ALL ROCK MULCH SHRUB BEDS SPECIFIED ON THE PLANS ONLY. NO LANDSCAPE FABRIC SHALL BE USED IN WOOD MULCH AREAS. NO PLASTIC WEED BARRIERS SHALL BE SPECIFIED. 31. ABSOLUTELY NO EXPOSED GROUND SHALL BE LEFT SHOWING ANYWHERE ON THE PROJECT AFTER MULCH HAS BEEN INSTALLED. 32. ALL PLANTING AREAS WITH LESS THAN A 4:1 GRADIENT SHALL RECEIVE A LAYER OF MULCH, TYPE AND DEPTH PER PLANS. SUBMIT 1 CUBIC FOOT SAMPLE OF MULCH (ONE SAMPLE PER TYPE) TO LANDSCAPE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. THE MULCH SHALL BE SPREAD EVENLY THROUGHOUT ALL PLANTING AREAS EXCEPT SLOPES 4:1 OR STEEPER, OR AS OTHERWISE DENOTED ON THE PLAN. 33. ALL PLANTING AREAS ON SLOPES OVER 4:1 SHALL RECEIVE COCONUT FIBER EROSION CONTROL NETTING FROM ROLLS. NETTING SHALL BE #CT-125, AS MANUFACTURED BY NORTH AMERICAN GREEN (OR APPROVED EQUAL). INSTALL AND STAKE PER MANUFACTURER'S SPECIFICATIONS. SEE ALSO THE CIVIL ENGINEER'S EROSION CONTROL PLAN. 5 6 7 4 8 9 11 10 12 PREVAILING WINDS NOTES: 1. SCARIFY SIDES OF PLANTING PIT PRIOR TO SETTING TREE. 2. REMOVE EXCESS SOIL APPLIED ON TOP OF THE ROOTBALL THAT COVERS THE ROOT FLARE. THE PLANTING HOLE DEPTH SHALL BE SUCH THAT THE ROOTBALL RESTS ON UNDISTURBED SOIL, AND THE ROOT FLARE IS 3"-5" ABOVE FINISH GRADE. 3. CUT OFF BOTTOM 1/3 OF WIRE BASKET BEFORE PLACING TREE IN HOLE, CUT OFF AND REMOVE REMAINDER OF BASKET AFTER TREE IS SET IN HOLE, REMOVE ALL NYLON TIES, TWINE, ROPE, AND OTHER PACKING MATERIAL. REMOVE ALL BURLAP FROM AROUND ROOTBALL. 4. TREE WRAP IS NOT TO BE USED ON ANY NEW PLANTINGS, EXCEPT IN LATE FALL PLANTING SITUATIONS, AND ONLY THEN AFTER CONSULTATION WITH THE LANDSCAPE ARCHITECT. WHEN WRAPPING TREE, WRAP FROM TRUNK FLARE TO LOWEST MAJOR BRANCH. 5. REMOVE ALL NURSERY STAKES AFTER PLANTING. 6. FOR TREES OVER 3" CALIPER, USE THREE STAKES OR DEADMEN (AS APPROPRIATE), SPACED EVENLY AROUND TREE. 7. DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. 1 2 3 TREE CANOPY. NYLON TREE STRAPS AT ENDS OF WIRES - SECURE TO STAKE OR DEADMEN WITH NAILS. 12 GAUGE GALVANIZED WIRE. SECURE TO TRUNK JUST ABOVE LOWEST MAJOR BRANCHES. PRESSURE-TREATED WOOD STAKE, 2" DIA. EXTEND STAKES 12" MIN. INTO UNDISTURBED SOIL. 24" X 3/4" P.V.C. MARKERS OVER WIRES. PRESSURE-TREATED WOOD DEADMEN, TWO PER TREE (MIN.). BURY OUTSIDE OF PLANTING PIT AND 18" MIN. INTO UNDISTURBED SOIL. WOOD MULCH TREE RING 3' DIA MIN. TYPE AND DEPTH PER PLANS. DO NOT PLACE MULCH WITHIN 3" OF TRUNK. FINISH GRADE. SEE PLANTING PLAN FOR GROUND COVER TREATMENT BACKFILL. AMEND AND FERTILIZE ONLY AS RECOMMENDED IN SOIL FERTILITY ANALYSIS. ROOT BALL-SEE NOTE 3, THIS DETAIL UNDISTURBED NATIVE SOIL TRUNK FLARE. PREVAILING WINDS STAKING EXAMPLES (PLAN VIEW) 1 5 6 TREE PLANTING DETAIL SCALE: NOT TO SCALE2 EVERGREEN TREE DECIDUOUS TREE 1 2 5 7 8 9 10 11 12 3 4 6 3X ROOTBALL DIA. 13 13 SOFT VELCRO, OR OTHER FABRIC WRAP 14 14 CENTRAL LEADER, SEE PLANTING NOTES MIN. 2 X ROOTBALLDIAMETERTHANROOTBALL4" MIN. TYP.MIN.6"DEEPER6" MIN. 1 3 4 5 6 FINISH GRADE. SEE PLANTING PLAN FOR GROUND COVER TREATMENT PLANT ROOT BALL. SET TOP ROOTBALL 2" ABOVE ADJECENT GRADE. IN BERMED AREAS SET ROOTBALL 2" ABOVE LOWER ADJECENT GRADE - INSTALL WATER RING (2 - 3" HT.) BACKFILL MIX (PER PLANTING SPECIFICATIONS). AMEND AND FERTILIZE ONLY AS RECOMMENDED IN SOIL FERTILITY ANALYSIS. JET BACKFILL WITH WATER TO ELIMINATE VOIDS. UNDISTURBED NATIVE SOIL. COMPACTED BACKFILL MIX (75%). 2 3 4 5 6 SHRUB AND PERENNIAL DETAIL SCALE: NOT TO SCALE1 2 SHREDDED BARK MULCH, 3" MIN. DEPTH, ROUGHLY THE EXTENTS OF ROOTBALL 1. USE ROSEMOUNT TREE PROTECTION NOTES (IF AVAILABLE). TREE PROTECTION NOTES BELOW SHALL BE USED FOR FURTHER INTEGRATION. 2. "PROTECTED ZONE" FOR EXISTING TREES: BEFORE BEGINNING ANY DEMOLITION OR CONSTRUCTION OPERATIONS, THE CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND ALL EXISTING TREES WITHIN THE CONSTRUCTION ZONE THAT ARE TO BE SAVED. THE FENCE SHALL BE INSTALLED NO CLOSER TO THE TREE THAN THE EDGE OF THE TREE'S PROTECTED ZONE, GENERALLY DEFINED AS THE AREA BEGINNING FIVE FEET OUTSIDE OF THE TREE'S DRIPLINE AND EXTENDING TOWARDS THE TREE (OR AS FAR AWAY FROM THE TRUNK AS PRACTICABLE). THE FENCING SHALL BE OF A MATERIAL AND HEIGHT ACCEPTABLE TO THE LANDSCAPE ARCHITECT. ALL CONTRACTORS AND THEIR CREWS SHALL NOT BE ALLOWED INSIDE THIS "PROTECTED ZONE" NOR SHALL THEY BE ALLOWED TO STORE OR DUMP FOREIGN MATERIALS WITHIN THIS AREA. NO WORK OF ANY KIND, INCLUDING TRENCHING, SHALL BE ALLOWED WITHIN THE PROTECTED ZONE EXCEPT AS DESCRIBED BELOW. THE FENCING SHALL REMAIN AROUND EACH TREE TO BE SAVED UNTIL THE COMPLETION OF CONSTRUCTION OPERATIONS. 3. TEMPORARY MULCH: TO ALLEVIATE SOIL COMPACTION IN ANTICIPATED AREAS OF HIGH CONSTRUCTION TRAFFIC, AND ONLY WHERE FENCING CANNOT BE SET FIVE FEET OUTSIDE OF THE DRIPLINE, THE CONTRACTOR SHALL INSTALL A LAYER OF MULCH, 9"-12" THICK, OVER ALL EXPOSED EARTH FROM THE TREE TRUNK TO 5' OUTSIDE OF THE DRIPLINE. THIS LAYER SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. WHEN PLANTING OPERATIONS ARE COMPLETED, THE MULCH SHALL BE REDISTRIBUTED THROUGHOUT ALL PLANTING AREAS IN A 3" THICK "PERMANENT" MULCH LAYER. 4. NECESSARY WORK: WHEN IT BECOMES NECESSARY TO ENTER THE "PROTECTED ZONE", SUCH AS FOR FINE GRADING, IRRIGATION INSTALLATION, AND PLANTING OPERATIONS, THE CONTRACTOR SHALL STRICTLY ADHERE TO THE FOLLOWING RULES: A. EVERY EFFORT SHALL BE MADE TO PRESERVE THE EXISTING GRADE AROUND PROTECTED TREES IN AS WIDE AN AREA AS POSSIBLE. B. TRENCHING WITHIN THE PROTECTED ZONE OF EXISTING TREES SHALL BE PERFORMED BY HAND, AND WITH EXTREME CARE NOT TO SEVER ROOTS 1-1/2" IN DIAMETER AND LARGER. WHERE ROOTS 1-1/2" IN DIAMETER AND LARGER ARE ENCOUNTERED, THE CONTRACTOR SHALL TUNNEL UNDER SAID ROOTS. EXPOSED ROOTS THAT HAVE BEEN TUNNELED UNDER SHALL BE WRAPPED IN WET BURLAP AND KEPT MOIST WHILE THE TRENCH IS OPEN. C. WHERE ROOTS 1-1/2" IN DIAMETER OR LARGER MUST BE CUT DUE TO EXTENSIVE GRADE CHANGES, THOSE ROOTS MUST BE EXPOSED BY HAND DIGGING AND CUT CLEANLY. RAGGED CUTS GENERALLY DO NOT HEAL PROPERLY, AND MAY LEAVE THE TREE OPEN TO PESTS AND PATHOGENS. D. WHERE TRENCHING NEAR TREES HAS ALREADY OCCURRED FROM PREVIOUS CONSTRUCTION OPERATIONS, THE CONTRACTOR SHALL MAKE EVERY EFFORT TO CONFINE HIS TRENCHING OPERATIONS TO THE PREVIOUSLY-CREATED TRENCHES, WHILE ADHERING TO THE CONDITIONS SET FORTH IN 3B. 4. POTENTIAL CONFLICTS: THE CONTRACTOR SHALL NOTIFY THE OWNER AND ARBORIST SHOULD ANY POTENTIAL CONFLICTS ARISE BETWEEN THESE SPECIFICATIONS AND/OR LARGE ROOTS ENCOUNTERED IN THE FIELD, AND CONSTRUCTION OPERATIONS. THE CONTRACTOR SHALL NOT TAKE ANY ACTION IN SUCH CONFLICTS WITHOUT THE ARBORIST'S WRITTEN APPROVAL. THE ARBORIST SHALL HAVE FINAL AUTHORITY OVER ALL METHODS NECESSARY TO HELP ENSURE THE PROTECTION AND SURVIVAL OF EXISTING TREES. 5. PRUNING: PRUNE ONLY THE TREES THAT ARE INDICATED ON THE PLANS AS REQUIRING PRUNING. PRUNE TREES ACCORDING TO INTERNATIONAL SOCIETY OF ARBORICULTURE / ANSI A300 STANDARDS: A. REMOVE ALL DEAD WOOD. B. PRUNE LIVE WOOD FOR HEALTH OR STRUCTURAL REASONS ONLY, INCLUDING THE NEED TO ELIMINATE DISEASED OR DAMAGED GROWTH, ELIMINATE STRUCTURALLY UNSOUND GROWTH, REDUCE THE POTENTIAL FOR WIND TOPPLING OR WIND DAMAGE, OR TO MAINTAIN GROWTH WITHIN LIMITED SPACE. DO NOT REMOVE MORE THAN 25% OF ANY TREE'S LIVE FOLIAGE IN ANY ONE GROWING SEASON. PRUNE ONLY TO INTERNATIONAL SOCIETY OF ARBORICULTURE/ANSI A300 STANDARDS, AND ONLY UNDER THE DIRECT SUPERVISION OF A CERTIFIED ARBORIST. C. FINAL CUTS SHALL BE MADE JUST OUTSIDE THE SHOULDER RING AREA. EXTREMELY FLUSHED CUTS WHICH PRODUCE LARGE WOUNDS SHALL NOT BE MADE. D. ALL TRIMMING CUTS SHALL BE PERFORMED IN SUCH A MANNER AS TO PROMOTE THE NATURAL GROWTH AND SHAPE OF EACH TREE SPECIES. E. IMPROPER PRUNING METHODS INCLUDING, BUT NOT LIMITED TO, "TOPPING", "TIPPING", "HEADING BACK", "DEHORNING", AND "LIONTAILING" WILL NOT BE ALLOWED. THE CONTRACTOR SHALL PAY FOR ALL WORK NECESSARY TO CORRECT SUCH PRUNING WHEN PERFORMED BY HIS CREWS OR SUBCONTRACTORS. F. SHOULD THE CONTRACTOR REQUIRE MORE INFORMATION, THE CONTRACTOR SHALL CONTACT THE ISA AT (217) 355-9411 FOR A COPY OF THE ANSI A300 PRUNING STANDARDS. CONTRACTOR SHALL ADHERE TO THE METHODS AND PRACTICES SET FORTH IN THIS DOCUMENT. 6. LANDSCAPE AND IRRIGATION (NATIVE TREES ONLY): ANY FUTURE LANDSCAPE AND IRRIGATION SHOULD ADHERE TO THE FOLLOWING GUIDELINES: A. NO IRRIGATION OR PLANTING SHOULD OCCUR CLOSER THAN 8'-10' FROM THE TRUNK. B. WHERE IRRIGATION DOES OCCUR WITHIN THE PROTECTED ZONE, DRIP IRRIGATION SHOULD BE USED WHEREVER POSSIBLE. ADDITIONALLY, ONLY PLANTS WITH LOW WATER NEEDS SHOULD BE PLANTED WITHIN THE PROTECTED ZONE, SPACED FAR APART WHERE CLOSE TO THE TREE. PLANTS MAY BE SPACED CLOSER TOGETHER NEAR THE EDGE OF THE PROTECTED ZONE. SEED ESTABLISHMENT NOTES 1. THE LANDSCAPE CONTRACTOR SHALL SEED ALL NATIVE SEED AREAS AS SOON AS POSSIBLE AFTER COMPLETION OF GRADING OPERATIONS. SOIL PREPARATION MEASURES IN AREAS TO BE SEEDED SHALL BE COMPLETED PRIOR TO SEEDING. 2. FOR PROPER ESTABLISHMENT, SEED SHALL BE INSTALLED WHEN AT LEAST THREE MONTHS REMAIN IN THE GROWING SEASON. IF LESS THAN THREE MONTHS REMAIN IN THE GROWING SEASON AT THE TIME OF SEEDING, THE LANDSCAPE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT AND OWNER. THE IRRIGATION SYSTEM FOR SEEDED AREAS SHALL BE FULLY OPERATIONAL AT THE TIME OF SEEDING. 3. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ADDITIONAL CORRECTIVE MEASURES, AT HIS OWN COST, TO SATISFY ESTABLISHMENT REQUIREMENTS AND ENSURE TIMELY CLOSEOUT. THESE MEASURES MAY INCLUDE, AT THE OWNER'S OPTION, RESEEDING OF SPARSELY GERMINATED AREAS AND/OR INSTALLATION OF SOD IN ALL SEEDED AREAS. 1. ALL SEED MIXES AVAILABLE THROUGH: MINNESOTA NATIVE LANDSCAPES 2. DRYLAND SEED MIXES ARE AVAILABLE AS FOLLOWS: MNL MESIC PRAIRE MIX 3. ALL SEED APPLICATIONS SHALL BE DRILL SEEDED, WITH HYDROSLURRY APPLIED OVER THE SEED BED AFTER SEEDING. THE SLURRY MIX SHALL CONTAIN THE FOLLOWING: LBS./1,000 SF WOOD FIBER MULCH 46 15-15-15 ORGANIC FERTILIZER 9 ORGANIC BINDER 4 SEED NOTES FLOOR PLAN 100' - 0" T.O. TOWER PARAPET 140' - 0" SECOND FLOOR 110' - 8" THIRD FLOOR 121' - 4" B.O. STRUCT. 132' - 0" T.O. LOW PARAPET 137' - 0" 28' - 6"36"CMU-3 CMU-1 E-3 E-2 E-1 PT-1 E-2 E-2 CMU-1 CMU-1 E-2 FLOOR PLAN 100' - 0" T.O. TOWER PARAPET 140' - 0" SECOND FLOOR 110' - 8" THIRD FLOOR 121' - 4" B.O. STRUCT. 132' - 0" T.O. LOW PARAPET 137' - 0" E-3 CMU-3 CMU-1 E-2 E-1 CMU-2 E-3 G-1SF-1CMU-1 FLOOR PLAN 100' - 0" T.O. TOWER PARAPET 140' - 0" SECOND FLOOR 110' - 8" THIRD FLOOR 121' - 4" B.O. STRUCT. 132' - 0" T.O. LOW PARAPET 137' - 0" 28' - 6"36"PRELIMINARY SIGNAGE SIZES - IMAGE NATIONAL TO VERIFY E-3 CMU-2 E-2 E-1 CMU-1 CMU-3 FLOOR PLAN 100' - 0" T.O. TOWER PARAPET 140' - 0" SECOND FLOOR 110' - 8" THIRD FLOOR 121' - 4" B.O. STRUCT. 132' - 0" T.O. LOW PARAPET 137' - 0" E-3 CMU-1 E-2 E-1 PT-1 PT-1CMU-1 CMU-1 Planning. Architecture. Engineering. 2017. Galloway & Company, Inc. All Rights Reserved 6162 S. Willow Drive, Suite 320 c Greenwood Village, CO 80111 303.770.8884 O www.gallowayUS.com Date: Checked By: Project No: Drawn By: COPYRIGHT THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT, AND MAY NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. COPYRIGHTS AND INFRINGEMENTS WILL BE ENFORCED AND PROSECUTED. SHEET TITLE: STAMP NOT FOR BIDDING NOT FOR CONSTRUCTIONPRELIMINARY4/10/2018 3:58:33 PM ARCHITECTURAL ELEVATIONS A2.1 PS0000046 KAB GAR 04/10/1815854 Chippendale Ave W., Rosemount, MNPUBLIC STORAGEROSEMOUNT, MNPS#25552PS0000046-A2.1-ARCHITECTURAL ELEVATIONS-PLANNING-SCALE: 1/16" = 1'-0"1 SOUTH ELEVATION SCALE: 1/16" = 1'-0"3 NORTH ELEVATION SCALE: 1/16" = 1'-0"2 WEST ELEVATION SCALE: 1/16" = 1'-0"4 EAST ELEVATION SF-1 STOREFRONT WINDOW SYSTEM ANODIZED ALUMINUM G-2 SPANDREL GLAZING OPACI-COAT-300 #3-0770-WARM GRAY G-1 1" INSULATED VISION GLAZING CLEAR LOW-E PT-2 PAINT SHERWIN WILLIAMS "CASABLANCA" #2060 PT-1 PAINT SPANISH MOSS CMU-3 PRECISION FACE CMU; PAINTED MATCH SAND CMU-2 PRECISION FACE CMU; PAINTED MATCH PANTONE 1665C (PS ORANGE) CMU-1 SPLIT FACE CMU LOCAL TO MATCH COBBLESTONE MP-1 CANOPY MATCH PS ORANGE E-3 EXTERIOR INSULATION FINISHING SYSTEM PANTONE 1665C (PS ORANGE) E-2 EXTERIOR INSULATION FINISHING SYSTEM SHERWIN WILLIAMS "SAND" #2059 + 25% E-1 EXTERIOR INSULATION FINISHING SYSTEM SHERWIN WILLIAMS "CASABLANCA" #2060 LABEL MATERIAL COLOR MATERIAL LEGEND # Date Issue/Description MEMORANDUM DATE: April 17, 2018 TO: Anthony Nemcek, Planner CC: Kim Lindquist, Community Development Director Stacy Bodsberg, Planning & Personnel Secretary Brian Erickson, Director of Public Works/City Engineer FROM: Mitch Hatcher, Project Engineer RE: Public Storage Engineering Review SUBMITTAL: The plans for Public Storage have been prepared by Galloway dated March 27, 2018. Engineering review comments were generated from the following documents included in the submittal:  Civil Construction Drawings  Drainage Report  Project Narrative GENERAL COMMENTS: 1. Street and utility construction shall be installed in accordance with the 2015 City of Rosemount General Specifications and Standard Detail Plates and the Engineering Guidelines. 2. City inspection of public street and utility connection is required during construction. 3. A bond or letter of credit in the amount of $50,000 will be required for the work to connect to city utilities and roadway work within Chippendale Avenue. 4. The developer is required to obtain a NPDES Construction Stormwater Permit and provide a copy of the approved SWPPP to the City prior to the issuance of a grading permit and start of any construction activity. 5. The applicant has been working with the City to update the easement agreement for the Drainage & Utility Easement on the site. This agreement will need to be recorded prior to any construction activity. 6. The 60-foot Drainage & Utility Easement should be shown on all plan sheets. 7. Final copies of the plan will need to be signed by a licensed professional engineer. 8. Upon completion of the street, sanitary sewer, watermain, and storm sewer construction, the City requires record drawings. See Engineering Guidelines for submittal and formatting requirements. STORMWATER COMMENTS: 9. Regional basin SP-2447 (Geronime Pond) has been designed to accommodate the water quality and quantity requirements for this site. The offsite ponding fee will be calculated for the redevelopment area at 5.03 acres x $9,017/acre = $45,355.51. 10. While utilizing the offsite ponding, the site will need to manage discharges rates not to exceed the capacity of the existing storm sewer system. 11. 15-inch storm sewer stubs have been provided into the site and should be used if possible instead of having to make new connections within Chippendale Avenue. 12. Atlas 14 rainfall depths should be used with the MSE3 rainfall distribution when modeling ponding, infiltration, and storm sewer sizing. 13. The proposed storm sewer design appears to be oversized. The storm sewer pipe sizing should be designed to accommodate the 10-year event. 14. All low points and ponds need to have EOF routes called out with flow arrows on the grading plan. At least one foot of freeboard must be maintained from the EOF to all adjacent building low openings. 15. Pretreatment is required prior to discharging to an infiltration area. UTILITY COMMENTS: 16. Only one connection to the watermain within Chippendale Avenue should be made. The city preference would be a wet tap type connection. 17. Label 8” watermain material type. Ductile Iron Pipe should be used. 18. The sanitary sewer connection should be made to the stub/service provided in the southwest of the redevelopment area and northwest of the existing site. This will avoid making a connection to the 37-foot-deep connection to the 12-inch sanitary sewer as proposed. Should you have any questions or comments regarding the items listed above, please contact me at 651-322-2015. Planning Commission Regular Meeting Minutes May 12, 1998 Page 5 Public Hearing: Secure Mini Storage PUD Chairperson Droste opened the public hearing for the Secure Mini Storage PUD. The recording secretary has placed the Affidavit of Mailing and Posting of a Public Hearing on file with the City. However, publication of the Public Hearing notice was not accomplished. Therefore, final action on this application will not be taken until the May 26, 1998 meeting, following publication of the notice. Mr. Pearson presented the revised PUD development plan for a mini storage facility east of Chippendale Ave. The first phase of this development consists of eleven storage buildings, including a climate controlled area, office and a manager's accessory apartment. The buildings will consist of rock -face concrete block on the walls facing adjacent properties. Steel picket fencing will be installed in the gaps between the buildings. There is intense landscaping along the perimeter of the property, meeting the minimum requirements. Variances for setback are needed for three buildings located 10' -15' from the railroad right -of -way. The setback requirement is 30'. All other standards have been met. The railroad has given approval for grading in the right -of -way. Chairperson Droste opened the floor to the Commissioners. There were discussions concerning the relocation of Chippendale Ave., fencing around the facility, and development of the second phase. Chairperson Droste opened the floor to the Applicant. Tony Vavoulis of Secure Mini Storage was present. In response to Commissioner inquiries, Mr. Vavoulis indicated landscaping will be installed on the Chippendale Avenue side along both Phase 1 and 2, but will not be installed along the north or railroad sides of Phase 2. Phase 2 will not be blacktopped at this time. Mr. Vavoulis presented pictures showing the color and design of the proposed buildings and fencing. Chairperson Droste opened the floor to the public. There were no comments. MOTION by Droste to close the public hearing. Seconded by Weisensel. Ayes: DeBettignies, Tentinger, Droste, and Weisensel. Nays: 0. Absent: Shoe Corrigan. Motion carried. MOTION by DeBettignies to continue the public hearing on the Secure Mini Storage Planned Unit Development to 7:00 p.m. on May 26, 1998. Seconded by Droste. Ayes: Tentinger, Droste, Weisensel, and DeBettignies. Nays: 0. Absent: Shoe Corrigan. Motion carried. Public Hearing: Wensmann /RCD Real Estate Lot Division Chairperson Droste opened the public hearing for the Wensmann/RCD Real Estate Lot Division. The recording secretary has placed the Affidavit of Mailing and Posting of a Public Hearing on file with the City. However, publication of the Public Hearing notice was not accomplished. Therefore, the public hearing will be continued to May 26, 1998, following publication of the notice.