Loading...
HomeMy WebLinkAbout4.b. Prestwick Place 20th Addition EXECUTIVE SUMMARY Planning Commission Meeting: April 14, 2020 Tentative City Council Meeting: April 21, 2020 AGENDA ITEM: 18-41-FP: Request by Prestwick, LLC, for Final Plat Approval for Prestwick Place 20th Addition AGENDA SECTION: Consent PREPARED BY: Anthony Nemcek, Planner AGENDA NO. 4.b. ATTACHMENTS: Site Location; Final Plat; Preliminary Plat, Grading Plan; Light and Signage Plan; Easement Vacation Sketch; Engineer’s Memo dated March 31, 2020; Park and Recreation Director’s Memorandum dated March 16, 2020 APPROVED BY: KL RECOMMENDED ACTION: Motion to recommend that the City Council approve the Final Plat for Prestwick Place 20th Addition, subject to the following conditions: 1. Execution of a subdivision agreement 2. Drainage and utility easements with storm sewer infrastructure, except ponding or infiltration areas, may contain fences, but shall be required to include gates to provide truck access; shall prohibit sheds or other accessory structures; and shall prohibit landscaping that would impede drainage. 3. Provision of $10,560 for Landscaping Surety 4. Provision of $91,800 for Fee-in-Lieu of Park Dedication 5. Compliance with the conditions and standards within the City Engineer’s Memorandum dated March 31, 2020. SUMMARY Applicant: Prestwick, LLC. (Scott Johnson) Comp. Guide Plan Designation: LDR – Low Density Residential Current Zoning: R-1-PUD Low Density Residential with the Prestwick Place Planned Unit Development (R-1: PUD) Gross Area: 10.32 Acres Net Area: 10.32 Acres Lots/Units: 27 Single Family Lots Gross Density: 2.62 units/acre Net (Met Council) Density: 2.62 units/acre The Planning Commission is being asked to consider a Final Plat request from Prestwick, LLC for Prestwick Place 20th Addition to allow development of 27 single-family lots. The final plat is necessary to facilitate subdivision of the property into individual residential lots, outlots, and public streets. Staff finds the application consistent with the Prestwick Place 13th Addition Preliminary Plat (which covers this area) and recommends approval of this application subject to the conditions listed above. 2 BACKGROUND The Planning Commission recommended approval of a preliminary plat and planned unit development (PUD) master development plan for Prestwick Place 13th Addition to allow 191 lots on 73 acres at its July 26, 2016 meeting. The City Council approved the preliminary plat and PUD plans at a later meeting with a slight reduction in the overall number of lots to 186. The applicant subsequently submitted a final plat for the first phase of development within the plat area, which was approved on September 6, 2017. The first phase was located along Akron Avenue in the far eastern portion of the preliminary plat area. The applicant subsequently received approval for the second phase of development, but rather than continuing to plat lots from east to the west, the applicant shifted to the far western portion of the project area for the second phase. The primary reason for the revised phasing was to be able to construct a model home closer to Connemara Trail and provide more direct access into the development from Connemara Trail. This phase is the final phase of development with the overall Prestwick Place 13th Addition preliminary plat area. The proposed final plat represents the final development phase within the Prestwick 13th preliminary plat area, and would create 27 single-family lots. In addition to the residential lots, the applicant will be dedicating right-of-way completing Ashford Path running east to west connecting the overall development area as well as completing the connections that remain following previous development phases. ISSUE ANALYSIS Legal Authority. The final plat application is Quasi-Judicial because the City has a set of standards and requirements for reviewing this type of application that is described in detail below. Generally, if the final plat meets the ordinance requirements it must be approved. Land Use and Zoning . The subject property is guided LDR – Low Density Residential and zoned R-1, Low Density Residential with the Prestwick Place 13th Addition Planned Unit Development (PUD). As a result, the property is subject to all the standards of the R-1, Low Density Residential zoning districts as well as the standards for detached single family units contained in the PUD. The Prestwick PUD included several deviations from the base R-1 zoning; the most notable include the following: 1. Section 11-2-15 F. Single Family Detached Dwelling Garage Requirements: The home designs do not need to include an option for a three garage stall. 2. Section 11-4-5 F. 1. R-1 Minimum Lot Area: The minimum lot area shall be 8,600 square feet for interior lots and 10,200 square feet for corner lots. 3. Section 11-4-5 F. 2. R-1 Minimum Lot Width: The minimum lot width shall be 65 feet for interior lots and 80 feet for corner lots. 4. Section 11-4-5 F. 4. R-1 Minimum Front Yard Setback: The minimum front yard setback shall be 25 feet. 5. Section 11-4-5 F. 5. R-1 Minimum Side Yard Setback: The minimum side yard setback shall be 7.5 feet. 6. Section 11-4-5 F. 9. R-1 Maximum Lot Coverage: The maximum lot coverage shall be forty percent (40%) for lots less than 9,750 square feet in size and thirty-five percent (35%) for greater than 9,750 square feet. The final plat is consistent with the preliminary plat that was approved in 2016. Many of the other standards are addressed at the building permit stage when an individual site survey is reviewed by the City. Final Plat. Standards for reviewing subdivision requests are detailed in Title 12 of the Rosemount City Code. This section of the Code outlines the two-step Preliminary and Final Plat process for land 3 subdivision. In this case, the preliminary plat was approved on September 6, 2016 consisting of 186 single family lots. The current application proposes to plat 27 single family lots for Prestwick Place 20th Addition and to dedicate the easements necessary to construct the storm water infiltration area within the overall development area. The developer has made some very minor modifications to the preliminary plat in order to accommodate wider easements over certain lots as required by the City Engineer. Taking these adjustments into account, the Prestwick Place 20th Addition Final Plat is consistent with the approved Prestwick Place 13th Addition Preliminary Plat. In conjunction with the final plat request, the developer is also proposing to vacate existing drainage and utility easements that were provided over this area. The existing blanket easement will then be replaced with easements as delineated on the final plat. The Planning Commission is not required to take action on the easement vacation request; easement vacation is a Council action. However, the map showing existing easements to be vacated is provided for information. Parks and Open Space. The Prestwick Place 19th Addition creates 27 buildable lots from 10.32 acres. Land was previously dedicated for Ailesbury Park; therefore, staff is recommending that the developer pay cash in lieu of land to fulfill the parks dedication requirement. The total amount to be provided is $91,800 (27 units x $3,400 per unit). Engineering All sidewalks and other public improvement depicted on the preliminary development plans are included on the attached submission materials. The City Engineer has provided a review memorandum for the proposed final plat. The applicant has provided updated plans that address comments contained in the Engineer’s review memo, which are included in the attachments. No issues of significance were identified by the City Engineer. RECOMMENDATION Staff is recommending approval of the final plat, subject to conditions, based on the information provided by the applicant and reviewed within this report 100100SOUTHWEST CORNER OFSEC. 22, TWP. 115, RGE. 19NORTHWEST CORNER OFSEC. 27, TWP. 115, RGE. 19SOUTH LINE OF THE WEST 1/2 OFTHE SOUTHWEST 1/4 OF SEC. 22,TWP. 115, RGE. 19WEST LINE OF THE EAST 1/2 OFTHE SOUTHWEST 1/4 OF SEC. 22,TWP. 115, RGE. 19NORTHERLY L INE OF OUTLOT A ,PRESTWICK PLACE 19TH ADD IT ION60606060N0°05'18"W 465.82 N67°08'07"E 813 .74606012341234567891011126543124561232131606060Δ ΔΔ I N S E T(SEE SHEET 2 OF 2)DENOTES 1/2" IRON MONUMENT FOUND,UNLESS OTHERWISE SHOWN.DENOTES DAKOTA COUNTY C.I.M. FOUNDTHE NORTHERLY LINE OF OUTLOT A, PRESTWICK PLACE19TH ADDITION HAS AN ASSUMED BEARING OF N67°08'07"ENO MONUMENT SYMBOL SHOWN AT ANY STATUTE REQUIRED LOCATION,INDICATES A PLAT MONUMENT WILL BE SET AND SHALL BE IN PLACE WITHINONE YEAR OF THE FILING OF THE PLAT. SAID MONUMENTS SHALL BE 1/2INCH BY 14 INCH IRON MONUMENTS MARKED BY LICENSE NUMBER 19086.22VICINITY MAPKNOW ALL PERSONS BY THESE PRESENTS: That Prestwick LLC, a Minnesota limited liability company, owner of the following described property:Outlot A, PRESTWICK PLACE 19TH ADDITION, according to the recorded plat thereof, Dakota County, Minnesota, EXCEPTING THEREFROM that part which lies within the West Half of the Southwest Quarter of Section 22,Township 115, Range 19, Dakota County, Minnesota.That part of Outlot A, PRESTWICK PLACE 19TH ADDITION, according to the recorded plat thereof, Dakota County, Minnesota, which lies within the West Half of the Southwest Quarter of Section 22, Township 115, Range 19,Dakota County, Minnesota.Has caused the same to be surveyed and platted as PRESTWICK PLACE 20TH ADDITION and does hereby dedicate to the public for public use the public ways and the drainage and utility easements as created by this plat.In witness whereof said Prestwick LLC, a Minnesota limited liability company, has caused these presents to be signed by its proper officer this ________ day of ___________________, 20 _______.Prestwick LLCBy ___________________________________________, its PresidentDean Scott JohnsonSTATE OF MINNESOTACOUNTY OF____________________The foregoing instrument was acknowledged before me this ______ day of ________________, 20 ______, by Dean Scott Johnson, President of Prestwick LLC, a Minnesota limited liability company, on behalf of the limitedliability company._______________________________________Signature_______________________________________PrintNotary Public, ____________ County, MinnesotaMy Commission Expires ____________________I, Russell P. Damlo, do hereby certify that this plat was prepared by me or under my direct supervision; that I am a duly Licensed Land Surveyor in the State of Minnesota; that this plat is a correct representation of the boundarysurvey; that all mathematical data and labels are correctly designated on this plat; that all monuments depicted on this plat have been, or will be correctly set within one year; that all water boundaries and wet lands, as defined inMinnesota Statutes, Section 505.01, Subd. 3, as of the date of this certificate are shown and labeled on this plat; and all public ways are shown and labeled on this plat.Dated this ________ day of ____________________, 20 ____.____________________________________Russell P. Damlo, Land SurveyorMinnesota License No. 19086STATE OF MINNESOTACOUNTY OF____________________The foregoing surveyor's certificate was acknowledged before me this ______ day of ___________________, 20 _____, by Russell P. Damlo, Minnesota License No. 19086._______________________________________Signature_______________________________________PrintNotary Public, ____________ County, MinnesotaMy Commission Expires ____________________CITY PLANNING COMMISSION, CITY OF ROSEMOUNT, STATE OF MINNESOTAApproved by the Planning Commission of the City of Rosemount, Minnesota, this __________ day of _____________________, 20 ______. __________________________ChairCITY COUNCIL, CITY OF ROSEMOUNT, STATE OF MINNESOTAThis plat was approved by the City Council of the City of Rosemount, Minnesota, this __________ day of __________________, 20 _______, and hereby certifies compliance with all requirements as set forth in MinnesotaStatutes, Section 505.03, Subd. 2. _____________________________________ _____________________________________Mayor City ClerkCOUNTY SURVEYOR, COUNTY OF DAKOTA, STATE OF MINNESOTAI hereby certify that in accordance with Minnesota Statutes, Section 505.021, Subd. 11, this plat has been reviewed and approved this _________ day of ____________________, 20 ______.By: __________________________________Todd B. TollefsonDakota County SurveyorDEPARTMENT OF PROPERTY TAXATION AND RECORDS,COUNTY OF DAKOTA, STATE OF MINNESOTAPursuant to Minnesota Statutes, Section 505.021, Subd. 9, taxes payable in the year 20 _________ on the land hereinbefore described have been paid. Also, pursuant to Minnesota Statutes, Section 272.12, there are nodelinquent taxes and transfer entered on this ___________ day of ______________________, 20 _____._____________________________________Amy T. Koethe, DirectorDepartment of Property Taxation and RecordsREGISTRAR OF TITLES, COUNTY OF DAKOTA, STATE OF MINNESOTAI hereby certify that this plat of PRESTWICK PLACE 20TH ADDITION was filed in the office of the Registrar of Titles for public record on this _______ day of ___________________, 20 _____, at _____ o'clock ___. M., and wasduly filed in Book ______________________________ of Plats, Page _______________________, as Document Number _________________________._____________________________________Amy T. Koethe, Registrar of TitlesCOUNTY RECORDER, COUNTY OF DAKOTA, STATE OF MINNESOTAI hereby certify that this plat of PRESTWICK PLACE 20TH ADDITION was filed in the office of the County Recorder for public record on this _________ day of ______________________, 20 ______, at _____ o'clock ___. M.,and was duly filed in Book _________________________ of Plats on Page ______________________ as Document Number _________________________._____________________________________Amy T. Koethe, County RecorderSITE 7651241131029181365432154316221ASHFORD PATHASHDALE AVENUEABERCORN AVENUEN67°08'07"E866.19N22°51'53"W260.6817.53R=3970.00CH=17.53C.BRG.=S67°24'41"WΔ=0°15'11"N22°53'42"W102.62Δ=22°58'47"R=270.00108.29Δ=3°23'46"R=409.7624.29S12°23'28"W75.44 246.86N22°51'53"WS22°51'53"E258.31S22°51'53"E259.98S22°51'53"E256.42S22°51'53"E254.59S22°51'53"E252.71S22°51'53"E250.81S22°51'53"E252.95N22°51'53"W258.00S22°51'53"E262.77S22°51'53"E263.98N22°51'53"W260.50N22°51'53"W252.37S16°07'12"E149.38N26°08'51"W131.00N22°53'47"W88.44N85°18'40"E125.00S85°17'06"E135.00S0°50'39"W 69.16 S11°53' 4 6 " W 64.41145.35N75°23'40"E111.2134.1440.21 56.319.6055.5260.4132.3442.80147.77S26°55'54"E38.08S67°08'07"W160.31N73°38'20"E5.25S11°21'49"E130.00N75°14'25"E130.33S85°17'06"E203.86N85°17'06"W164.14 S0°18'11"W 31.54 S16° 3 3 ' 0 3 " W 65.00N68°45'09"E68.62S89°54'55"E13.19 N0°05'05"E 14.10 54.90 N4°42'54"E 85.02Δ=4°43'47"17.76Δ=0°59'16"68.85Δ=5°53'16"78.03Δ=16°33'31"Δ=9°2 4 '14 " 4 4.3 2Δ=7°31'06"82.5773.79Δ=7°25'37"74.26Δ=4°07'52"15.15Δ=2°10'18"75.41Δ=10°48'42"S63°04'06"W8.9981.8218.2665.0067.0069.0065.0067.0067.6967.5069.5066.5065.0067.0065.0065.00Δ=0°41'07"47.4836.68Δ=0°31'46"28.3467.0365.0366.5359.569.96Δ=0°46'55"Δ=5°06'20"65.0567.8845.5521.62Δ=1°16'37"Δ=3°50'27"65.02Δ=4°04'54"69.10Δ=3°59'15"67.51Δ=8°08'20"65.292.5130.0030.0030303030303030303030303030.1130.1130.0030.00N21°14'51"W135.00N21°14'51"W135.00N21°14'51"W149.69S81°22'40"W 144.0146.80N87°37'25"W138.5885.88Δ=1°13'16"65.0065.0086.8856.3172.72Δ=12°37'31"6 3 .3 5 Δ =10 °5 9 '5 5 " 54.31 13.47Δ=2°20'19"143.8673.65 90.49 42.62DRAINAGE AND UT IL ITY EASEMENT81.99R=429.61Δ=10°56'04"230.16R=1000.00Δ=13°11'13"100.98Δ=5°47'08"129.18Δ=7°24'05"107.74R=599.23Δ=10°18'07"72.52S11°21'49"E115.93S62°51'53 "W71.93R=700.00Δ=5°53'16"39.60246.88286.48S68°45'09"W86.31S21°14'51"E135.94R=300.00Δ=25°57'45"54.31 S4°42'54"W 85.02R=4000.00Δ=1°13'04"130.00130.00140.00140.00140.00143237.0138.4375.141010101010 10 7.57.57.515.0029.6997.218.63Δ=01°29'53"DRAINAGEAND UT IL ITYEASEMENT 7.507.507.507.50BEING 5 FEET IN WIDTH AND ADJOINING SIDELOT LINES,UNLESS OTHERWISE INDICATED,AND 10 FEET IN WIDTH AND ADJOININGSTREET RIGHT-OF-WAY LINES AND REAR LOTLINES, UNLESS OTHERWISE INDICATED.DRAINAGE AND UTILITY EASEMENTSDENOTES 1/2" IRON MONUMENT FOUND,UNLESS OTHERWISE SHOWN.ARE SHOWN THUS551010 INSETNO MONUMENT SYMBOL SHOWN AT ANY STATUTEREQUIRED LOCATION INDICATES A PLAT MONUMENTWILL BE SET AND SHALL BE IN PLACE WITHIN ONE YEAROF THE FILING OF THE PLAT. SAID MONUMENTS SHALL BE1/2 INCH BY 14 INCH IRON MONUMENTS MARKED BYLICENSE NUMBER 19086. CONNEMARA TRAIL140TH STREETAUBURN AVENUEADELAIDE AVENUEABERCORN AVENUE141ST STREET WESTABBE Y F I E L D A V E N U E 141STSTREET WESTCO U N T Y R O A D N O . 7 3 AKR O N A V E N U E NORTHERN NATURAL GAS COMPANY GAS PIPELINE EASEMENTL8 B512,578 SFL1 B911,814 SFL6 B69,218 SFL38 B147,992 SFL4 B411,200 SFL6 B411,209 SFL7 B416,725 SFL5 B411,200 SFL1 B426,703 SFL3 B411,200 SFL2 B411,200 SFL12 B514,222 SFL13 B515,173 SFL19 B59,520 SFL1 B511,987 SFL2 B59,145 SFL3 B59,045 SFL5 B59,045 SFL4 B59,045 SFL6 B59,311 SFL7 B510,336 SFL9 B512,102 SFL10 B510,049 SFL11 B510,355 SFL23 B512,951 SFL22 B510,472 SFL21 B510,027 SFL20 B59,412 SFL16 B59,404 SFL18 B59,323 SFL14 B59,041 SFL 3 B311,007 SFL 4 B38,613 SFL 10 B314,382 SFL 7 B38,775 SFL 6 B38,775 SFL 5 B38,775 SFL 13 B315,765 SFL 1 B38,977 SFL 2 B310,055 SFL 14 B312,489 SFL 15 B315,866 SFL 16 B312,042 SFL 9 B310,711 SFL 23 B310,109 SFL 18 B315,104 SFL 17 B313,741 SFL 19 B311,792 SFL 20 B39,893 SFL 21 B310,633 SFL 22 B310,338 SFL 26 B310,633 SFL 24 B310,789 SFL 25 B310,560 SFL 27 B314,691 SFL2 B212,579 SFL1 B212,466 SFL3 B210,112 SFL4 B29,459 SFL5 B29,111 SFL8 B29,211 SFL11 B211,760 SFL9 B29,436 SFL10 B29,927 SFL7 B29,275 SFL6 B29,307 SFL1 B113,384 SFL2 B115,437 SFL3 B117,813 SFL4 B126,890 SFL5 B120,259 SFL9 B117,123 SFL11 B118,036 SFL10 B117,659 SFL7 B117,234 SFL8 B118,012 SFL14 B117,110 SFL17 B118,123 SFL16 B117,208 SFL15 B116,174 SFL13 B116,917 SFL12 B116,717 SFL20 B117,925 SFL22 B116,864 SFL21 B116,335 SFL19 B117,452 SFL18 B117,143 SFL23 B117,499 SFL28 B117,457 SFL26 B117,888 SFL27 B116,930 SFL25 B117,244 SFL24 B116,608 SFL29 B116,871 SFL30 B117,781 SFL31 B117,131 SFL32 B116,492 SFL33 B117,370 SFL52 B123,704 SFL47 B110,400 SFL50 B114,083 SFL49 B111,963 SFL48 B110,400 SFL45 B110,400 SFL46 B110,400 SFL44 B110,855 SFL51 B118,775 SFL53 B125,989 SFL43 B111,835 SFL42 B113,832 SFL41 B118,114 SFL40 B127,556 SFL39 B145,691 SFL36 B126,154 SFL37 B135,259 SFL35 B122,255 SFL34 B117,355 SFL10 B913,309 SFL11 B914,681 SFL12 B910,489 SFL8 B99,100 SFL14 B99,100 SFL15 B99,100 SFL13 B99,764 SFL16 B99,100 SFL6 B99,100 SFL4 B99,876 SFL3 B99,691 SFL2 B99,382 SFL18 B98,969 SFL17 B99,404 SFL7 B99,100 SFL5 B99,043 SFL1 B813,988 SFL5 B89,380 SFL4 B89,380 SFL14 B215,768 SFL1 B614,743 SFL8 B69,217 SFL7 B611,734 SFL4 B610,724 SFL5 B610,219 SFL3 B69,154 SFL17 B59,009 SFL15 B59,491 SFL 11 B313,606 SFL7 B811,096 SFL6 B810,540 SFL13 B810,962 SFL 12 B313,268 SFL 8 B39,534 SFL1 B712,358 SFL6 B79,882 SFL12 B79,967 SFL6 B116,473 SFL12 B210,619 SFL15 B215,008 SFL2 B69,650 SFL10 B78,970 SFL7 B79,904 SFL4 B712,295 SFL5 B79,866 SFL3 B78,775 SFL8 B710,673 SFL9 B78,471 SFL11 B712,109 SFL2 B79,920 SFL13 B710,736 SFL10 B89,554 SFL11 B89,916 SFL12 B89,962 SFL14 B812,536 SFL15 B810,819 SFL2 B89,174 SFL9 B814,252 SFL3 B89,082 SFL8 B89,542 SFL9 B99,075 SFL13 B29,160 SFAILESBURY AVENUE 140TH STREETASHFORD PATHAS H F O R D P A T H ABB E Y F I E L D A V E N U E ASH F I E L D A V E N U E AS H D A L E A V E N U EASHBROOK PATHAILESBURY AVENUE ASHFORD PATHABERCORN AV E N U E ASHBROOK PATH609595 6060606060 60 606060606060 60 60606060606060 60606060L34 B341,846 SF140TH COURT141.495.0140.495.0 170.571.8 136.5 247.855.6142.3252.758.548.0 114.2251.633.132.496.565.0255.365.1259.267.167.0262.6 65.0263.965.067.0262.967.069.0259.569.1254.956.98.365.067.0250.167.269.0246.938.930.265.0252.465.367.0260.567.5264.069.169.0262.8 67.0258.045.621.670.2252.870.465.0250.865.1252.657.110.067.0254.669.069.065.0256.465.067.0258.367.069.0260.140.728.365.0260.765.067.0260.267.0258.78.156.965.0256.769.069.0254.767.067.0252.865.065.0250.769.069.0249.820.043.875.2116.6268.158.4131.8316 . 858.4167.24 1 1 . 358.4126.1114. 024.74 1 7 . 058.489.4165. 4360.658.4166. 1251.258.4121. 7193.258.4101. 5165.758.4 86.8160.016.9 43.2 160.067.8 67.8160.065.0 65.0160.065.0 65.0160.065.0 65.0166.444.6 15.3 160.088.5195.95 8.3 103. 5258.45 8 . 3 126. 1 242.358.348.547.514.0 90.565.3156.4131.4 65.0 65.0 65.065.069.043.725.347.3 154.0115 .4148.599.8 117.319.971.6133.0 62.784.0131.1 62.781.7136.4 52.114.070.5139.9 67.051.415.8137.0 67.067.1135.4 38.328.056.712.8140. 8 65.865.26.4154. 6 64.471.6179 . 0 67.2147.1 139.2121.9128.8100.0 65.7 136.647.2 1 0 9.3 140.065.0 65.0 140.065.0 65.0 50.5 65.0 140.065.0 65.0 65.0 65.0 71.1 140.065.0 125.210 9.3139.838.2 40.7 1 3 1 . 2 109.140.837.2131.3 104.552.6 45.769.579.25 9.8 140.763.7 58.5140.044.8 18.5 140.065.0140.065.0 140.0139.560.8 38.3 65.034.676.740.5 52.9 17.8 84.9140.252.664.8134.4138.851.3 28.5 65.0140.067.0140.067.0 67.0140.050.5 6.8105.040.1136.310 7.686.9107.8 93.739.790.4130.0137.0139.8140.0104.641.287.2150.0 76.2145.1111.232.3 82.6 85.0131.034.117.860.488.4 64 . 4 55.568.89.656.378.0125.044.3 40. 2135.069.2 69. 0130.391.0 87. 847.768.5130.0105.830.0 5 8.0 24.3 42.8 145.3135.0 18.381.89 4.330.090.0135.0 69.267.767.7135.0 67.267.067.0135.0 72.267.067.0135.0 72.567.067.0135.570.372.551.414.1149.672.589.458.515.869.1100.458.4101.368.964.654.5 91.0142.067.0158.0 15.267.625.736.6114.768.158.795.0 159.3145.154.6130.3139.5 67.069.0135.6 68.0132.6 66.0132.1 68.0133.958.89.3138.167.0142.969.0147.89.075.4149.4 15.174.373.8 75.1100.138.1186.065.3141.265.0135.026.9110.065.285.14 9 .2 15.9130.0 85.1128.7 135.0 65.074.0135.0 65.0135.0 65.0121.065.065.0135.0 65.0158.3 65.034.834.227.6 171.1104.764.5 172.254.5 48.2131.426.878.017.875.2144. 147.9130.544.3141.747 .9 126.0128.54 4.3 81.473.438.2153.8 17.835.739.177.320.510.3209.1 26.034.8101.2123.2158.5 55.9147.1 7.749.9100.4148.2 67.067.0149.3 71.571.5150.4 69.069.0151.4 67.067.0152.5 71.071.0153.6 69.0154.6 69.069.072.3125.4 58.777.469.092.0 69.165.071.6ΔΔΔ80.916.52 7 .7 128.7 142.471.365.813 0 . 0 130 . 075.470.087.154. 2 31. 3 33.7 67.0 59.3 33.9 35.6 69.5 68.3 70.0 88.8 85. 5 85.942.6108.3 47.4 30.5 67.8 62.7 125.263.768.569.191.3142 . 7 54. 3 63.3 72.7 56.3 86.965.065.05.2 97.246.8144.0149.7 135.0 135.0 68.665.03 1 . 5 26.5 73.6 64.0 84.463.363.480.5138. 7 132. 4 125.1 73.6 90.5 13.5 143.9138.6138.5141.722.4117.2 80.0 80.0 80.0 80.0 80.0 190.7 140.0190.780.080.080.080.034.545.5114.586.4140.6140.0140.0140.0140.0140.0R=60.00L28 B319,361 SFL29 B323,139 SFL30 B332,120 SFL31 B341,102 SFL32 B348,655 SFL33 B346,029 SF20.8104.2 50.2 19.8 70.0 65.0 65.0 65.0 135.0286.9425.1563.2701.4673.1645.055.1 60.3 15.276.1317.1152.7152.7152.714.5PHA S E 1 FUT U R E P H A S E S DRAINAGE & UTILITY EASEMENTAND CONSERVATION EASEMENTDRAINAGE & UTILITY EASEMENTAND CONSERVATION EASEMENTOUTLOT C, 72.59 ACRESPRESTWICK PLACESECOND ADDITIONPROPOSED RIGHT OF WAY: 13.34 ACRESTOTAL NO. OF LOTS 186NET DENSITY (OUTLOT C)2.56 Lots / AcEXISTING ZONING: AGPROPOSED ZONING: PUDEXISTING LEGAL DESCRIPTION:OUTLOT C, PRESTWICK PLACE 2ND ADDITION, ACCORDING TOTHE RECORDED PLAT ON FILE IN DAKOTA COUNTY, MINNESOTA.PID NO. 34-58601-00-030CONTACT INFORMATION: PRESTWICK, LLC (SCOTT JOHNSON)350 HIGHWAY 7, SUITE 125EXCELSIOR, MN 55331LAND OWNER:PRESTWICK, LLC (SCOTT JOHNSON)350 HIGHWAY 7, SUITE 125EXCELSIOR, MN 55331CONSULTANT:PROBE ENGINEERING CO., INC.1000 E. 146TH STREET, SUITE 240BURNSVILLE, MN 55337PH. NO. 952-432-3000SETBACKSFRONT - 30 FEETSIDE STREET - 20 FEETSIDE - 7.5 FEETREAR - 25 FEETDATE____________ REG. NO._________I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.17-15-16PMREVISED 141ST CT. BLOCK 3 & ADDED EASEMENTS28-8-16PMREVISED BLOCK 3 LAYOUT & REV PER CITY 1-1 2-1 3-1 4-1 5-1 6-1 7-1 8-1 9-1 10-1 11-1 12-1 13-1 1-2 2-2 2-3 3-3 4-3 5-3 6-3 1-3 3-4 4-4 5-4 6-4 2-4 1-4 FBWO FBWO FBWO FBWO FBWO FBWO FBLO FBLO FBWO FBWO FBWO FBWO FBWO FB FB FB FB FB FB FB FB FBFB FB FBLO8.3%7.6%7.9%9.1%6.2%6.8%9.5%7.4%7.3%7.2%6.9%FBLO FBLO ABERCORN AVENUEASHFIELD AVENUE4+50951.565+00952.146+00951.50HP: 5+15.41Elev: 952.18ASHFORD PATH 2+00953.713+00951.514+00949.4517+50 952.71 18+00 952.25 19+00 951.25 20+00 950.25 21+00 949.25 22+00 948.33 23+00 949.16 24+00 950.72 25+00 952.27 26+00 952.79 LP: 22+14.17 Elev: 948.30 HP: 25+75.32 Elev: 952.86 9.7%9.3%8.5% 8. 4 % 8. 2 % 6.8%9.3%9.1%8.5%7.7%6. 9 % 7.6 % 0.7' DROP 0.7' DROP 4:1 MAX SLOPE INFILTRATION AREA HWL: 941.7 10 DAY SNOW MELT=942.58 4:1 MAX SLOPE 954.5954.1954.0 953.6 952.9 953.3 953.6954.0955.9956.3952.8957.8955.5 955.1 955.1 954.8 954.0 953.6 953.0 953.3 955.5 947.3 955.0 946.8 945.8 954.0 953.0 944.8 944.5 952.7 951.0 946.0 951.0 946.0 952.7 944.5 953.0 944.8 953.5 945.3 954.5 946.3 955.5955.1956.5956.1953.3 953.2 952.3 951.3 950.3 949.2 948.9949.4950.1950.8 952.2 951.5 951.6 950.8 950.0 949.1 952 . 6 95 4 . 5 95 5 . 8 EX. E . O . F . 951. 8 951.3 952.5 951.4 952. 0 95 5 . 0 95 2 . 6 952.7 952.0 953.3 95 6 . 6 95 7 . 2954.9953.6952.595 5 . 8 952.1 95 3 . 4 95 4 . 9 953.5 952.7 951.7 950.7 949.4 952.9953. 7 95 5 . 7 95 7 . 3 953.6 953.0954.0953.0952.5952.2950.5950.5952.2952.5953.5954.5955.0E. O . F . 95 3 . 0 E. O . F . 95 2 . 9 9 5 1 . 8952.5E.O.F. 949.5 944.2 943.3 943.3 943.2 943.2 943.6 943.3 943.2 943.3 944.1 944.2 944.6 ???955.995 6 . 0ASHDALE AVENUEMAINTANCE ACCESSLO=947.8 LO=947.3 LO=946.8 LO=945.8 LO=945.3 LO=945.0 LO=946.5 LO=946.5 LO=945.0 LO=946.3LO=945.3 LO=947.3 LO=947.8 LO=951.5 LO=950.5 LO=954.3 LO=953.6 LO=954.3 LO=956.6 LO=954.8 LO=953.3 LO=954.0 LO=954.3 LO=955.8 LO=955.8 LO=956.8 LO=955.8 946.5 946.0 945.5 944.5 944.0 943.7 942.7 942.7 943.7 944.0 945.0 946.0 946.5 947.0 946.0 945.0 944.3 945.0 944.0 945.0 945.8 946.5 946.5 946.5 947.3 947.3 945.5 E.O.F. 952.5 950.7 Note: INFILTROMETER TESTING P O S T C O N S T R U C T I O N 947.3 946.8 955.5 955.0 956.0 955.0 951.0 950.0 953.4 EX. E.O.F. 948.5 947.9 951.8 952.3 953.0 952.9 953.3 CB R:949.2 EX CB R:952.4 EX CB R:951.4 EX CB R:951.0 EX CB R:952.4 EX CB R:947.48.4%7.5%7.3%7.3%955.0954.4955.0954.5954 954 952 950 948 946 944 942 942 944 946 948 950 952 954 956 954 954 952 950 948 948 954 952 950954 954 952 950 948 946 944 942 942 944 946 948 950 952 954 956 954956 954 958 956 952 9549569 5 4954 952950 952952952952 950 952 952952950952954956 958958956952946 944 944 950 95 0 952944 944 9 4 4 952 950948946946948952954 948 95 4 944 944 944 946 954 952 950950952 952952 952 952952 952954956954954954954 954954952952 95 2 954 954 952 952950 952956 940 942 944 940 940 950 942 942 944 946 948 952 940 940 942 942 944 946 948 940 950 942 944 946 948 952 954 956 944 EXISTING STOCK PI L E 6 1 3 0 C U B I C Y A R D S SELECT GRANULAR S S DATE____________ REG. NO._________ I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. GRADING PLAN ROSEMOUNT,MINNESOTA 1 1 PM 2-3-2020 AS SHOWN 17055.00 EXCELSIOR, MN 55331 350 HIGHWAY 7, SUITE 125 PRESTWICK LLC 1. POSITIVE DRAINAGE AT 2% OR GREATER SHALL BE CONSTRUCTED AROUND ALL PROPOSED BUILDINGS. SWALES SHALL BE CONSTRUCTED AT A MINIMUM OF 2% GRADE. 2. CONTRACTOR SHALL KEEP ADJACENT STREETS FREE OF DEBRIS AND PREVENT OFFSITE TRACKING OF DEBRIS IN ACCORDANCE WITH THE CITY OF ROSEMOUNT. ROCK CONSTRUCTION ENTRANCES SHALL BE INSTALLED AND MAINTAINED AT EACH CONSTRUCTION ENTRANCE. STREET SWEEPING REQUIRED AS NEEDED. 3. CONTRACTOR SHALL NOTIFY GOPHER STATE ONE CALL AT 800-252-1166, 48 HOURS PRIOR TO ANY EXCAVATION 4. STOCKPILES SHALL BE PROTECTED WITH SILT FENCE. 5. CONTRACTOR SHALL OBTAIN ANY PERMITS NECESSARY FOR THE WORK. 6. CONTRACTOR SHALL ENSURE ALL CONSTRUCTION ACTIVITIES COMPLY WITH THE NPDES PERMIT. INCLUDING BUT NOT LIMITED TO DEWATERING OPERATIONS. 7. DRIVEWAY GRADES SHALL BE BETWEEN 3% AND 10% LOWEST ALLOWABLE FLOOR ELEV = 1 FT ABOVE 100 YEAR HWL OF ADJACENT POND LOWEST ALLOWABLE OPENING ELEV = 3 FT ABOVE 100 YEAR HWL OF ADJACENT POND AND 1 FT ABOVE AN EOF 1-1 941.8 946.8GARAGE FLOOR ELEVATION PROPOSED LOT BLOCK PROPOSED GROUND ELEVATION FBHOUSE TYPE 4.8%DRIVEWAY SLOPE MAXIMUM LOT COVERAGE LOTS OVER 9,750 SF - 35% LOTS AT OR BELOW 9,750 SF - 40% SETBACKS FRONT - 30 FEET SIDE STREET - 25 FEET SIDE - 7.5 FEET REAR - 25 FEET DENOTES CONSERVATION POST FBWO - FULL BASEMENT WALKOUT FBLO - FULL BASEMENT LOOKOUT FB - FULL BASEMENT 1 7-2-19 JM ADDED SURVEY SHOTS FROM 6-28-19 LO=942.5 937.8 PROPOSED LOW OPENING LOWEST ALLOWABLE FLOOR ELEVATION 3/27/2020 48365 DENOTES AS BUILT GROUND ELEVATION 2 3-25-20 JM REVISED LOTS 7 & 8, BLOCK 1 LOWEST FLOOR ELEV. 1-1 2-1 3-1 4-1 5-1 6-1 7-1 8-1 9-1 10-1 11-1 12-1 13-1 1-2 2-2 2-3 3-3 4-3 5-3 6-3 1-3 3-4 4-4 5-4 6-4 2-4 1-4 FBWO FBWO FBWO FBWO FBWO FBWO FBLO FBLO FBWO FBWO FBWO FBWO FBWO FB FB FB FB FB FB FB FB FBFB FB FBLO8.3%7.6%7.9%9.1%6.2%6.8%9.5%7.4%7.3%7.2%6.9%FBLO FBLO ABERCORN AVENUEASHFIELD AVENUE4+50951.565+00952.146+00951.50HP: 5+15.41Elev: 952.18ASHFORD PATH 2+00953.713+00951.514+00949.4517+50 952.71 18+00 952.25 19+00 951.25 20+00 950.25 21+00 949.25 22+00 948.33 23+00 949.16 24+00 950.72 25+00 952.27 26+00 952.79 LP: 22+14.17 Elev: 948.30 HP: 25+75.32 Elev: 952.86 9.7%9.3%8.5% 8. 4 % 8. 2 % 6.8%9.3%9.1%8.5%7.7%6. 9 % 7.6 % 0.7' DROP 0.7' DROP 4:1 MAX SLOPE INFILTRATION AREA HWL: 941.7 10 DAY SNOW MELT=942.58 4:1 MAX SLOPE 954.5954.1954.0 953.6 952.9 953.3 953.6954.0955.9956.3952.8957.8955.5 955.1 955.1 954.8 954.0 953.6 953.0 953.3 955.5 947.3 955.0 946.8 945.8 954.0 953.0 944.8 944.5 952.7 951.0 946.0 951.0 946.0 952.7 944.5 953.0 944.8 953.5 945.3 954.5 946.3 955.5955.1956.5956.1953.3 953.2 952.3 951.3 950.3 949.2 948.9949.4950.1950.8 952.2 951.5 951.6 950.8 950.0 949.1 952 . 6 95 4 . 5 95 5 . 8 EX. E . O . F . 951. 8 951.3 952.5 951.4 952. 0 95 5 . 0 95 2 . 6 952.7 952.0 953.3 95 6 . 6 95 7 . 2954.9953.6952.595 5 . 8 952.1 95 3 . 4 95 4 . 9 953.5 952.7 951.7 950.7 949.4 952.9953. 7 95 5 . 7 95 7 . 3 953.6 953.0954.0953.0952.5952.2950.5950.5952.2952.5953.5954.5955.0E. O . F . 95 3 . 0 E. O . F . 95 2 . 9 9 5 1 . 8952.5E.O.F. 949.5 944.2 943.3 943.3 943.2 943.2 943.6 943.3 943.2 943.3 944.1 944.2 944.6 ???955.995 6 . 0ASHDALE AVENUEMAINTANCE ACCESSLO=947.8 LO=947.3 LO=946.8 LO=945.8 LO=945.3 LO=945.0 LO=946.5 LO=946.5 LO=945.0 LO=946.3LO=945.3 LO=947.3 LO=947.8 LO=951.5 LO=950.5 LO=954.3 LO=953.6 LO=954.3 LO=956.6 LO=954.8 LO=953.3 LO=954.0 LO=954.3 LO=955.8 LO=955.8 LO=956.8 LO=955.8 946.5 946.0 945.5 944.5 944.0 943.7 942.7 942.7 943.7 944.0 945.0 946.0 946.5 947.0 946.0 945.0 944.3 945.0 944.0 945.0 945.8 946.5 946.5 946.5 947.3 947.3 945.5 E.O.F. 952.5 950.7 Note: INFILTROMETER TESTING P O S T C O N S T R U C T I O N 947.3 946.8 955.5 955.0 956.0 955.0 951.0 950.0 953.4 EX. E.O.F. 948.5 947.9 951.8 952.3 953.0 952.9 953.3 CB R:949.2 EX CB R:952.4 EX CB R:951.4 EX CB R:951.0 EX CB R:952.4 EX CB R:947.48.4%7.5%7.3%7.3%955.0954.4955.0954.5954 954 952 950 948 946 944 942 942 944 946 948 950 952 954 956 954 954 952 950 948 948 954 952 950954 954 952 950 948 946 944 942 942 944 946 948 950 952 954 956 954956 954 958 956 952 9549569 5 4954 952950 952952952952 950 952 952952950952954956 958958956952946 944 944 950 95 0 952944 944 9 4 4 952 950948946946948952954 948 95 4 944 944 944 946 954 952 950950952 952952 952 952952 952954956954954954954 954954952952 95 2 954 954 952 952950 952956 940 942 944 940 940 950 942 942 944 946 948 952 940 940 942 942 944 946 948 940 950 942 944 946 948 952 954 956 944 EXISTING STOCK PI L E 6 1 3 0 C U B I C Y A R D S SELECT GRANULAR S S DATE____________ REG. NO._________ I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. LIGHT AND SIGNAGE PLAN ROSEMOUNT,MINNESOTA 1 1 JM 3-25-2020 AS SHOWN 17055.00 EXCELSIOR, MN 55331 350 HIGHWAY 7, SUITE 125 PRESTWICK LLC 1. SIGNAGE LOCATIONS SHOWN ARE APPROXIMATE AND SHALLE INSTALLED PER CITY REQUIREMENTS. 2. FINAL DETERMINATION OF LIGHT LOCATIONS ARE TO BE DIRECTED PER LOCAL UTILITY COMPANY. DENOTES STOP SIGN LOCATION 1 7-2-19 JM ADDED SURVEY SHOTS FROM 6-28-196-13-2019 48365 DENOTES PROPOSED LIGHT POLE LOCATION 2 3-25-20 JM REVISED LOTS 7 & 8, BLOCK 1 LOWEST FLOOR ELEV. S 5432124653OUTLOT A8911479101286751322143756121DRAINAGE AND UTILITY EASEMENT OVER ALL OF OUTLOT A,PRESTWICK PLACE 19TH ADDITION TO BE VACATED.DATE____________ REG. NO._________I HEREBY CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA.EASEMENT VACATIONROSEMOUNT,MINNESOTA11JJ2-3-20201"=100'17055.00EXCELSIOR, MN 55331350 HIGHWAY 7, SUITE 125PRESTWICK LLC MEMORANDUM To: Anthony Nemcek, Planner CC: Kim Lindquist, Community Development Director Brian Erickson, Director of Public Works/City Engineer Stacy Bodsberg, Planning and Personnel Secretary From: Stephanie Smith, Assistant City Engineer Date: March 31, 2019 Subject: Prestwick Place 20th Final Plat- Engineering Review SUBMITTAL: The plans for Prestwick Place 20th Addition have been prepared by Probe Engineering Company, dated February 3rd, 2020. Engineering review comments were generated from the followi ng documents included in the submittal: ▫ Prest wick Place 20th Grading Plan ▫ Prestwick Place 20th Addition Final Plat ▫ Easement Vacation Exhibit The review of this development is also based on submittals for Prestwick Place 19th Addition. GENERAL COMMENTS: The developer has informed the City of their intent to have the construction plans designed by the City and have the construction administrated privately by the developer. The developer has deposited $40,000 with the City to start the plan design. 1. The development fees below are estimated based on the current Schedule of Rates and Fees. These fees are due with the final plat and subdivision agreement.  GIS Fees: $60/unit  Sanitary Sewer Trunk Charge: $1075/acre  Watermain Trunk Charge: $6500/acre  Storm S ewer Trunk Charge: $6865/ net developable acre 2. Per the existing Joint Development and Cost Sharing Agreement, the developer is responsible for the costs of adjacent roadways. These costs are as follows: Prestwick Cost Share Spreadsheet: G:\ENGPROJ\431\Prestwick Place Cost Share Tabulation - 2020.xlsm  The developer is responsible for costs associated with upgrading Akron Avenue. This cost is $278.40/acre.  The developer is responsible for costs associated with the extension of Connemara Trail between Bloomfield and Akron Avenue. This cost is estimated at $12,643.12/acre. 3. Plans must be signed by an engineer registered in the state of Minnesota. RIGHT OF WAY AND EASEMENTS : The plat consists of re -platting an existing outlot into the lots of Prestwick Place 20th Addition. Right -of-way will be dedicated for the local streets that will serve the new lots. Per City Code, Drainage and Utility (D&U) easements will be dedicated around the perimeter of the lots and over the stormwater BMPs. 4. The existing drainage and utility easements must be vacated prior to and concurrently with recording the final plat. 5. E asements are required over all ponding and infiltration areas, and shall encompass at minimum the HWL and all naturally vegetated areas. Signage for easements shall be provided by the developer prior to sale of properties, and an extended maintenance warranty shall be required to ensure establishment of the naturally vegetated areas. 6. Storm sewer is proposed along the side and back lot lines of many properties to convey rear yard drainage. Drainage and utility easements along these lines shall prohibit the construction of structures such as sheds to ensure that access can be provided for storm sewer maintenance. Fences are allowed but shall not restrict drainage and are required to include gates for truck access over the drainage and utility easement. Also, landscaping that will block access should be prohibited. 7. Trees are not allowed to be planted within drainage and utility easements, over the proposed storm sewer, or within a pond access location. Trees located on individual properties shall not be planted near the sanitary sewer and water service lines. 8. The developer shall work with their builders to ensure that homebuyers have knowledge of the infiltration basin and large backyard easements on the lots north of Ashford Path. Easement restrictions should be added as a restriction on the property deed. 9. The width of drainage and utility easements over all public utilities shall be verified during final design. STREET AND SIDEWALK 10. Street profiles shall callout and verify the tie-in points with the portions of the road constructed with previous additions. 11. Intersection stationing shall be called out on the street profiles. 12. The applicant shall submit a signage plan for review. 13. A street lighting plan shall be submitted for review and must comply with City standards. Street light requirements are detailed below:  at all public street intersections  at the end of all cul-de-sacs  at regularly spaced intervals (not to exceed 500’) on alternating sides of the street  at all instances where the road configuration warrants extra illumination as determined by City Engineering Staff WATER AND SANITARY SEWER 14. The water and sanitary sewer construction plans will be designed, consistent with City of Rosemount Engineering Guidelines and Standard Specifications and Detail Plates, by the City’s consultant WSB at the applicant’s expense. STORMWATER The applicant proposes an infiltration basin behind the lots north of Ashford Path. 15. Infiltrometer testing to verify the infiltration rate shall be required prior to public acceptance of the infiltration basin. 16. Soil amendment is required in basins where the infiltration rate is higher than 8.3 inches per hour. WSB Engineering reviewed the Prestwick Place 20th Addition grading and stormwater management plan on behalf of the City. The recommended conditions of approval are summarized below: 17. A minimum of 1’ of separation is required between the basement floor elevation and 100-year high water elevation. The following houses are not meeting this: 8-1, and 7- 1. 18. The last grading sent grading plan in our records did not have a maintenance access shown, which is now included in the grading plan and plat. The access is between houses 8-1 and 7-1 with no change in setback, and there is no language included to pre vent a property owner building on top of the access. The maintenance access is 15’ wide according to the plat, and is an 8% slope from the grading plan, it is meeting the City requirements. Because the houses are 18.5’ apart, this access is not in a preferred location. Should you have any questions or comments regarding the items listed above, please contact me at 651-322-2015. MEMORANDUM To: Kim Lindquist, Community Development Director Kyle Klatt, Senior Planner Anthony Nemcek , Planner From: Dan Schultz, Parks and Recreation Director Date: March 16, 2020 Subject: Prestwick Place 20th Additional Final Plat The Parks and Recreation Department recently re viewed the final plat for the Prestwick Place 20th Addition. After reviewing the plans, the Parks and Recreation Department staff has the following comments: PARKS DEDICATION The park s dedication requirement for the 27 units in the 20th addition is to be cash in lieu of land. The cash in lieu of land dedication for 27 units is $91,800 (27 units x $3,400 per unit). The cash dedication is to be paid prior to, or at the time of execution of the final plat. Please let me know if you have any questions about this memo.