Loading...
HomeMy WebLinkAbout13857 ADAN AVEf 1 (949.3 E.O.F I N89°52'21"W 130.00 I I � 301 � - � House Sodded � I I I ^ � � I � �r v � I p� 49.3 X 952.4 X 952.5 952.5 � 950.1 952.1 x 951.6 0 95�3 I I I 949.8 x x 950.9 I � sas.3 # sas.s x ssi.z rn I � 950.3 g5p 2 I � I 949.2 � � � X 950.8 x 950.8 � 950.5 I I � I r - - - - - - - - - - - - - - - - - o��-- - - - - - - - -x-sst.r� 10 v � I I Y�� I 951.3 x 951.2 x 951.4 951.9 I 950.6 x Y I 949.5 X x g49.11 X 949.6 X 950.7 r . 949.9 � - � x sas.e �-� �'`s 26.0 I'- 21.5 r'' o,. esi,�.� 9�i.s I � � I I� � ..�" �� ,,` � I� I � I i /"� i � I 950.5 I � I ,, � I I i ✓+ i �,.� f 950.9 949.4 � � co � � � ��• ' ..�� I � � I w I 949.5 x I rt=� x 951.2 i /� � p",F i N .° 2.Q p � � v � � � I �% 7 � I X 949.1 � x 95�. f�F � / � 0 �� •!' 3 I � � I Y � Z - 949.0 � x 950.2 � � L fr'`� �' j � O � I � Y -� � � � , �'�, ,,g'`� � o -� � � � o i i w C a ; �n � , .,,'°� �O Q N N I � > I � � � � �.,.s � � ��°'° � � � � � � � w � �N i_ d 2 �`' f=+ �+ ✓' I \ 1 Q I I 0 E I 951.8 X � �;.,� r �51.9 \ \ 949� � � � I O m I x 948.7 x 949.9 x 953.3 x '` ,r'`�y52.2 ,'' ss,. ss,.°25.5 --- eso.z Y � � - X V � � I 950.6 ' �,�'� 14.0 � ssi.e � ' ►'7 Q i � 949� 948.2 � � 951.9 ��950 � Q I ,�,�'' �,, . 9�2.1 952.0 951.9 x 951.2I � � O I ,,✓ ,J' ` o x 949.8 I Q a I O f..� +,, O _ � 1 � � O � I °'y �''''� , ,,o' a x ss,.� saa.q O Z I� � sas.o !- „,�'' 29.3 .� , _ X sso.� v p I 947.5�9 --- -Y--- - S'rJ.O ----------- B.t 951.7 Y � v I X 949.7 950.2 x 950.3 950.7 51.7 950.7 I � � x 948. � �0 X 949.0 - - - - - - - - - - x 950.1 951.1 X x 950.5 �0 948.9 I I �x 947.7 - - - x 948.6 950.3�I��• 9�5�3- 95U.� 949.1x � � ` I x 948.5 I I �� 1� X 947.5 X � x 949.0 948.6�948.9x - � 948.4 948.7 948.6 x �I/ I 948.3 x 948.2X948.4 948.SX x948.8 X 949.0 948.7 Q � �/ x 947.3 949.7 x 948.7 � I � _ 948.4� X 949.1 948.5 47.3 948.7 948.2 X � 947.7� I I 947.4I I � � v � House Rough Grade 30 v � IV II �I v I Y I I 1 N89°52'21"W 130.00 (sa�.s E.O.F � Service invert elevation = 940.1 (As-built by others) � Denotes iron pipe 5 Lowest opening elevation per grading plan :952.1 Lot area = 8680 SF �'p° Denotes service House area = 1905 SF ❑O Denotes television box Lowest floor elevation per grading plan : 949.1 Porch areo = 85 SF � Denotes electric box Sidewalk area = 67 SF � Denotes telephone box House elevations (Proposed� / As-built Driveway area = 651 SF x o00.00 Denotes existing elevation Lowest Footing Elevation ; 949.1 948.8 FTG Total Impervious Area = 2708 SF � ) � Im e�vlouS Covera e =31.2� ( 000.00 ) Denotes proposed elevation p g � Top Of Foundation Elev. ;(952.3) / 952.1 Denotes drainage flow direction � Denotes spike Garage Slab Elev. � Door ;(952.0� � 951.9 ■�����■ Denotes proposed retaining wall designed and built by others. ' �;ou��t t��vie���: 4 n '7-1-a 1 ,�-L��- Construction Notes: E��te� n 0 ` ��� �� ".7�� 1. Instali rock construction entrance. 0� 10� 20� 2. Install silt fence as needed for erosion control. 3. Sidewalks sha�� drain away from hoUse a minimum of ,.o�. REVISED 6/9/21 GRADING AS-BUILT 4. Contractor must verify driveway design. 5. Contractor must verify service elevation prior to construction. 6. Add or remove foundation ledge as required. SCale: 1�� = 20� General Notes: Benchmark: 1. Grading plan by Pioneer last dated 10-17-18 was used to determine We hereby certify to Lennar Corporation that this survey, plan or Top Nut Hydrant proposed elevations shown herein. report was prepared by me or under my direct supervision, and Lots 3-4 Block 2 2. This survey does not purport to show improvements or encroachments, that I am a duly licensed Land Surveyor under the laws of the Elevation = 953.38 except as shown, as surveyed by me or under my direct supervision. State of Minnesota, dated 07/24/20. 3. Proposed building dimensions shown are for horizontal location of structures on the lot only. Contact builder prior to construction for approved construction plans. Signed: io eer En ineering, P.A. R����zsSzoscakehoUse 4. No specific soils investigation has been performed on this lot by the SUfVByOf. 2.)II-]2-20FoundationAs-built The suitability of soils to support the specific house proposed is not the BY. 3.)oe-ov-zi a�ad��gAs-b���h responsibility of the surveyor. 5. This certificate does not purport to show easements other than those shown Peter J. Hawkinson, rofessional Land Surveyor on the recorded plat. Minnesota License No. 42299 email-phawkinsonC�pioneereng.com 6. Bearings shown are based on an assumed datum. PI�NEER Lot 5, B�o�k ,, �'1'l�12ee1'Zri�',P� GREYSTONE 7TH ADDITION Certificate of Survey for: CiVILENGMEERi LANDPLAN\CRS LAVDSI�RVCYf)RS L.4\DSC'>PCARCftITCCTS according to the recorded plat thereof I,eririaT COY�JOratlOri 2422 Enterprise Drive Ph.:(651)681-1914 Dakota COUflty, M innesota Mendota Heights,MN 55120 Fax:(651)681-9488 16305 36th Ave N Ste#600 www.pioneereng.com Address: 13857 Adan Avenue, Rosemount, Minnesota Plymouth,MN 55446-4270 House Model: Alden EI Elevation: B3 Phone:(952)249-3000/Fax:(952)404-1909 Project#:118304044 Folder#:8138 Drawn by:CWM Buyer: WINTER FOUNDATION n v;..,,PP,-F„R;�PP�;n� ����.��� �� � •�r��- ,��